HomeMy WebLinkAboutSUB-07F-97 WEST VALLEY ESTATES SUBDIVISION #2 & #3 ATTACHMENT16 18 19 v 2:0 v 21��"
I
� O `L
26,09' 60.00' 60.0060.00' 60.OV 5t 63' U33� al
N \ ,
..PALRANG SUBD.
SD
p � J = O 15 16
2
24
0,00' 60.00' 778'
2392' 65.00' 60,00' 6
\3 J h
c� P
Q �. 2 5 I-
p`�� / �C Op, 7G ° -7 "7.56' 60OG' 1 60. 0' 1 60.jou 78.3 ' F -
/ O 2
24 h0 Op a 74. 0' 4.95' 67.20' 62.70' 62.70' 44' W Q
S PROPOSED SANITARY SEWER LINE
PROPOSED CONS I. SEWER MANHOLE
-W- PROPOSED CONST. WATER LINE
- - - -EP- - -- - CONST. WATER LINE
- W ---- - EXIST. WATER LINE
EXIST. DITCH
11 LOT NUMBER
_ - rn
21 S d 5
�
II / 25 6 y U
o 0 20 19 0 18 26 o NOTES:
O / O �' 1. ALL SANITARY SEWER MAINS SHALL BE 8" 0 UNLESS OTHERWISE SHOWN.
O 44.62' 62.70' 62'.7d' S8.37 82.33' -� 2. ALL WATER MAINS SHALL BE 8" 0 UNLESS OTHERWISE SHOWN.
26 Opp" 6�1�0 00 ° Dry �00 --+- 3. STORM DRAINAGE AND CONTINUATION OF FLOOD IRRIGATION AND/OR
°O oo O o - W _ -� W DRAINS SHALL BE PROVIDED IN ACCORDANCE WITH CURRENT REQUIREMENTS
O
�p OF THE CITY OF CALDWELL AND GOVERNING IRRIGATION DISTRICT, � 6° OG 24 �o S
0
Op O `o' 276.39' 130.3G'
'�h t 27 pppp" 6�l�
I �� „ ,�.
N '89'25 07 E 252.29 yti• 60'p 25 O- 6ry. 48.38' 60.00' 60.00' 0 0U' �- a22s'
_ p
15' 65.06, 6 ,00' r 67,23' aU. �O° O°° b ° o W
6 O 0
�p0 3 0 2 1 $ O QY OP R
0 6° 'v o. 6� b� O Oo oa 8 _
41 26 CL
T I cy!R, 31 30 29 �' O h° �ti \ 5 L O 6 OD
V-� 00 'O °° b°° }"1' 28 N89 25'0 t"E ■
N 17
�N / G OS... ,
N LLd 65.00' 68:10' En
.. ;�� 'q- Op 6°O°09'O `J o....,° \` 37 0 O ..__.__r ENGINEER
v o• ti' 6 0 =
�, - g OpO, o o 1 7 0-
= 3 3 6a �° 7 19 0 18 0 0
o p r7 70,05' �- , bo °� s
o rn 71t.
co
Z M o j I J o. Off% OAS 83 ,� 01.97 W
IZ-O i 2 N u j 1 ) A. `-� : �� ��^ o° o° o ••� 21 ��� - EXISTING ZONE
`J 35�6 , 6° 6b ' ~ TOTAL SUBDIVISION AREA
o z i N89'25'T9" E rn v t 9 t�`t /)
1 v, I - eay 1p 30 / _ pp. b6 960 'Op. � W _ �.
'F O ti Q TOTAL LOTS
e g , 31 6b moo /10, / 82.75' J TOTAL R-1 BUILDABLE LOTS
1 W 37 'o �2' d DENSITY
N MIN. LOT SIZE
=
95A4'
5
O
0
ss.o4'
06
I, ,
I�
o
5 6
d�
95.03'
r
F.
Soo
to
V)
�.
95.03'
M I
!
J
0
�1
32 O a c 01.80 U7`.
1 11 24 �
6
33 25
J o � s 12 4 146.42'Lo
p 6
35.94' b 9
N 00'34'41" W 157.71'
29.46'
o 419� O U N P L A T`',T E P
100 �, 6
5.G0'
14 �"
N
Gt
c°n 35 i 100.00' _ 101.94'
N 37 0
28
95. 3
' m 100.00' iT)D.00'
42 A N 36 '
9 O o
f
m
WIM
Q
3
38
95.00'
N
w
ui
39 0
95.00
�'
40 0
95.00'
s
41
- 95.00'
206.02' � � - s
S 00'34'41" E L`' N DO'34'41" W
5.41' 24.46'
S 89'25'19" W o S 89'25'19" W
95.00' 0 95.00'
U N P L A T T E D
01.
a.
�o
8
oG.GG' S 07618107" W
37, 78'
100. S 00034'41" E
60.00'
100.00'
S $7'32'09" W
Sfa.03'
18'-6'
56'-0"
37'-0'
I
IS' -6"
CURB & GUTTER (TYR. AS PER
PLANS
56' RIGHT-OF-WAY
TYPICAL STREET SECTION
-NTS-
4'-0" C. 0"
EWALK
I
P /L
w
PHASE 1
PHASE
PHASE
J--B FARMS
203 11th AVENUE SOUTH
NAMPA, IDAHO 83651
(208) 466-7821
HUBBLE ENGINEERING INC.
9550 BETHEL COURT
BIOSE, IDAHO 83709
(208) 322-8992
PHA
PHASE3
R-1
R-1
13.84
10.57
66
53
63
52
4.6
4.9
6,000 sq. ft.
6,000 sq. ft.
VA .
- VICINITY MAP
N T S
L
L- -zf / C! c') l
THESE DRAWINGS, OR ANY PORTION THEREOF, SHALL NOT BE USE
DATE:
118 "eel
A HUBBLE 9550 BETHEL COURT WEST VALLEY ESTATES
EAVGINEERING, INC. BOISE, IDAHO 83709
sURv�yo ENGINEERING -SURVEYING -PLANNING
(208) 322-8992 SUBDIVISION NO. 2 AND NO. 3
�
ON ANY PROJECT OR EXTENSIONS OF THIS PROJECT EXCEPT BY
AGREEMENT IN WRITING WITH NUBBLE ENGINEERING, INC.
PRELIMINARY PLAT JOB NO.
A PORTION OF THE W1 /2 OF THE N W1 /4 OF 95-253
SECTION 3, T.31N., R.3W., B.M. CANYON COUNTY SHEET N0,
T.3N., R.3W_ 'R m r'n.mynNl rnl INITV 1