DATE: January 4 , 1999
TO: Linda James, Director, Developmental Services
FROM: Joseph Silva, Fire Marshal
SUBJECT: Change of Use for Proposed Church Building
located at 704 Blaine
If the above referenced project is approved the following
requirements will need to be met for Fire Protection:
1 . Premises Identification. All numbers or addresses shall be
6” high and placed above the front door on the of the building in
such a manner to be clearly visible from the street . The numbers
shall contrast with their background and be placed on the street
side of the building. UFC 901 . 4 . 4
2 . Portable Fire Extinguishers shall be installed in occupancies
and locations as set forth in this code and as required by the
Chief . UFC 1002 . 1 Fire Extinguishers shall be of the 2A 10BC
size and have the top of the extinguisher hung 3 ' to 5 ' off the
floor. Three fire extinguishers shall be provided. One shall be
located by each exit door.
3 . Emergency Power Equipment . Equipment providing emergency
power for exit illumination and exit signs shall be maintained in
an operable condition. UFC 1211 . 2 A plan shall be submitted for
their installation.
4 . Exit Sign Illumination. Signs shall be internally or
externally illuminated by the two electric lamps or shall be of an
approved self-luminous type . UFC 1212 .4 The exit signs shall be
provided above all approved exits .
5 . The building shall be provided with adequate exiting systems
as specified in the 1997 Uniform Building and Fire Codes .
oseph Silva
ire Marshal
ANY OVERLOOKED HAZARDOUS CONDITION AND/OR VIOLATION OF THE
BUILDING CODE OR FIRE CODE DOES NOT IMPLY APPROVAL OF SUCH
CONDITION OR VIOLATION