Loading...
HomeMy WebLinkAboutCFD_IsbellTownhomes 403 Blaine Street • Caldwell, ID 83605 • Phone 208-649-1266 • Fax 208-455-3014 Date 05/08/2026 Caldwell City – Planning and Zoning Re: Case Number: SPP26-000004 Dear, Planning & Zoning The Caldwell City Fire Department District has reviewed and can approve the application subject to compliance with all the following code requirements and conditions of approval. Any deviation from this plan is subject to Fire Department approval. Please note that unless stated otherwise, this memo represents the requirements of the 2018 International Fire Code (IFC) as adopted by the Idaho State Fire Marshal’s Office. Caldwell Fire Department Details Station 13 11925 Skyway St. Caldwell National Standards for Travel Time (90% of time) for first arriving unit: 4 minutes Nearest Fire Station: Station 11 Closest fire station (in miles) to site: 2.1 Miles Approximate response time to site: 8 Minutes Will this development have other significant impacts on the ability to provide services? No Will this development necessitate additional fire resources and/or equipment beyond current levels? If yes, please explain under “Adverse Impact Comments, Recommendations, and Fiscal Impact”. • Our department is currently operating with high resource utilization, and continued growth is contributing to increased service demand. Aligning staffing and resources with that demand will help maintain our current level of service. No 403 Blaine Street • Caldwell, ID 83605 • Phone 208-649-1266 • Fax 208-455-3014 Distance from Station Service Expectation Staffing & Apparatus Typical Response Time Goal 0–1 mile Immediate—high- priority First-due company (engine) ≤4min travel, ≤5min total 1–2 miles Very rapid—high- priority First-due company, backup ≤4min travel, ≤5min total 2–3 miles Rapid—standard coverage First-due w/ backup ≤6min travel, ≤9min total (full alarm) 3–4 miles Slower—moderate Closest available, limited 6–8min travel 4–5 miles Extended Closest company, delayed >8min travel, variable Properties located 3–4 miles from a fire station are at the limit of effective coverage and may experience service delays. Developments beyond 5 miles are generally not recognized by ISO as having fire protection, and response to these areas will be significantly delayed. Conditions: 1. Fire hydrants, capable of producing the required fire flow, shall be located along approved fire lanes. Fire hydrant spacing shall meet the requirements of IFC table C105.1.1 (IFC 507.3, IFC B105.2, IFC C105). 2. Roadway serving a fire hydrant shall be a minimum of 26-feet in width. (IFC D103.1) 3. Dead-end fire apparatus access roads exceeding 150 feet (45 720 mm) in length shall be provided with an approved area for turning around fire apparatus. (IFC 503.2.5) 4. Fire apparatus access roads shall have an unobstructed width of not less than 20 feet and an unobstructed vertical clearance of not less than 13 feet 6 inches. (IFC 503.2.1) 5. The minimum outside turning radius of a fire apparatus access road shall be 48 feet. The minimum inside turning radius shall be 28 feet. (IFC 503.2.4) 6. Fire apparatus access roads shall have an approved driving surface of asphalt, concrete or other approved driving surface and can support the 403 Blaine Street • Caldwell, ID 83605 • Phone 208-649-1266 • Fax 208-455-3014 imposed load of fire apparatus weighing at least 80,000 pounds. Please provide documentation the road surface meets this standard. (IFC D102.1) 7. Fire apparatus access roads shall not exceed 10 percent in grade. (IFC D103.2) 8. For streets having a width less than 33 feet back of curb to back of curb parking shall be restricted on one side; for streets having a width less than 27 feet back of curb to back of curb parking shall be restricted on both sides. A note on the face of the final plat is required noting the parking restriction prior to signing of the final plat. In addition, No Parking signs shall be installed in accordance with the requirements of the IFC. (IFC 503.8) 9. The FD Turn around shall be signed “No Parking Fire Lane” per 2018 IFC. 10. Where fire apparatus access roads or a water supply for fire protection are required to be installed, such protection shall be installed and made serviceable prior to and during the time of construction except where approved alternative methods of protection are provided. Temporary street signs shall be installed at each street intersection where construction of new roadways allows passage by vehicles in accordance with (IFC Section 505.2. General Requirement: Fire Department required fire hydrants, access, and street identification shall be installed prior to construction or storage of combustible materials on site. Provisions may be made for temporary access and identification measures. Specific building construction requirements of the International Building Code, International Fire Code and City of Caldwell Code will apply. However, these provisions are best addressed by a licensed Architect at time of building permit application. Regards, Joseph Bongiorno Fire Prevention Office Caldwell Rural Fire Protection District jbongiorno@cityofcaldwell.org