Loading...
HomeMy WebLinkAboutPID-Discharge-Approval1 Justin Pitcher From:Dave Watkins <davew@pioneerirrigation.com> Sent:Wednesday, March 25, 2026 11:14 AM To:Justin Pitcher Cc:Kirk Meyers; John Carpenter Subject:RE: Discharge into Bardsley Gulch Drain Justin, Based on the historic runoA design, Pioneer Irrigation District would accept the discharge into Bardsley Gulch Drain. Please let me know if you have further questions. Respectfully, Dave Watkins Assistant Superintendent Pioneer Irrigation District Cell (208) 249-2509 Office (208) 459-3617 From: Justin Pitcher <JPitcher@ardurra.com> Sent: Thursday, March 19, 2026 10:07 AM To: Dave Watkins <davew@pioneerirrigation.com> Cc: Kirk Meyers <kirk@pioneerirrigation.com>; John Carpenter <JCarpenter@ardurra.com> Subject: RE: Discharge into Bardsley Gulch Drain Dave, Good morning. I am reaching out to check in on the status of the review of the Farmway Crossing No. 1 subdivision. Farmway Crossing is located at the southwest corner of Ustick Rd and Farmway Rd. While this subdivision is not within PID’s jurisdiction area, we designed the storm drain system to discharge historic runo A into the Bardsley Gulch Drain. We submitted back in late October, early November of 2025. We are looking to get a formal approval from PID to discharge historic runo A into the Bardsley Gulch Drain. If you have any questions or if you need anything else to provide this approval, please feel free to give me a call at 208-790-1221. Thanks, City of Caldwell APPROVED FOR CONSTRUCTION These plans and/or specifications have been reviewed for compliance with the City of Caldwell specifications. This review does not relieve the owner, engineer, or contractor of the responsibility to design and/or construct these facilities in compliance with all current applicable federal, state, and local laws, rules, regulations, ordinances, orders of decisions, development agreements, or specifications. Inconsistencies not isolated by City staff shall not be construed as approved unless specifically addressed as a variance and granted by City Council as a variance. The City retains the right to enforce provisions of said document and policies even if inconsistencies are not noted by the City. Any revisions of these approved plans will require a resubmittal for a full review and approval. Name:Martin Gergen 2 Justin Pitcher Staff Engineer O: 208.442.6300 | M: 208.790.1221 jpitcher@ardurra.com From: Dave Watkins <davew@pioneerirrigation.com> Sent: Thursday, August 14, 2025 7:49 AM To: Justin Pitcher <JPitcher@ardurra.com> Cc: Kirk Meyers <kirk@pioneerirrigation.com> Subject: Discharge into Bardsley Gulch Drain Justin, See below, taken from current PID Standards. Please let me know if you have any questions. “ Proposed stormwater discharges shall be designed so as not to exceed the pre-urban development flow rate for the proposed drainage basin (discussed below). Further, proposed stormwater discharges shall be designed to preferentially drain to drainage ditches rather than to delivery ditches as a general matter. Therefore, proposed stormwater discharges shall be designed to discharge to drainage ditches rather than to irrigation delivery ditches when: (1) the subject property historically drained to a drainage ditch prior to subdivision, or (2) when the property to be drained is adjacent to a drainage ditch and drainage can be accomplished by gravity flow.” Respectfully, Dave Watkins Assistant Superintendent Pioneer Irrigation District Cell (208) 249-2509 Office (208) 459-3617