HomeMy WebLinkAboutHotelFloorPlan_HaystackApts_SaddleHilton_V190
'
-
1
1
"
20
'
-
0
"
24
'
-
0
"
40'-0"184'-0"20'-0"248'-6"24'-0"26'-0"
20
'
-
0
"
26
'
-
0
"
20
'
-
0
"
26
'
-
0
"
26'-0"20'-0"
25
'
-
0
"
26'-0"MIN
UP
UP
GENERAL NOTES: FLOOR PLAN
1.
2.
3.
4.
5.
6.
7.
8.
REFER TO 'G' SHEET GENERAL NOTES FOR DIMENSIONING, GRAPHIC, ABBREVIATIONS AND OTHER STANDARDS.REFER TO LANDSCAPE AND CIVIL DRAWINGS FOR GRADING AND SITE ELEMENTS ADJACENT TO BUILDING.TYP HINGE SIDE DOOR JAMB OFFSET DIMENSION NEAR ADJACENT WALLS SHALL BE 4" TO ROUGH OPENING U.N.O. (8" IN MASONRY WALLS - IF USED)REF. INDIVIDUAL UNIT, AND ENLARGED FLOOR PLANS FOR ADDITIONAL NOTES, DIM'S AND INFORMATION .SLAB PENETRATIONS AND OPENINGS ARE SHOWN SCHEMATICALLY ONLY, GENERAL CONTRACTOR TO COORDINATE THE SIZES AND LOCATIONS OF ALL DUCTS, PIPES, CONDUITS, CHASES AND OTHER OPENINGS WITH THE STRUCTURAL ENGINEER AND/OR ANY DESIGN-BUILD COMPONENT ENGINEER. ANY DEVIATIONS OR DISCREPANCIES AFFECTING THE DIMENSIONING OR VISUAL/SPATIAL DESIGN OF THESE DRAWINGS MAY NOT OCCUR WITHOUT NOTIFICATION AND ACCEPTANCE OF ARCHITECT.WALL ASSEMBLY TYPE TAGS APPLY TO THE FULL LENGTH OF CONTINUOUS WALLS INCLUDING OFFSETS AND AROUND CORNERS UNLESS INDICATED OTHERWISE.WALL ASSEMBLY TYPES DO NOT CONTAIN COMPLETE EXTERIOR CLADDING OR INTERIOR TRIM INFORMATION. REF. ELEVATIONS, FINISH SCHEDULE, AND DETAILS FOR ADDITIONAL INFORMATION.ELEVATION REFERENCES INDICATE TOP OF FINISH UNLESS NOTED OTHERWISE.
2644
POOL
009
150
POOL EQUIP
010
71
POOL STORAGE
012
1036
FITNESS
013
191
GUEST LAUNDRY
014
86
FIRE RISER
015231
MEN RESTROOM
008
228
WOMEN RESTROOM
007
706
FOOD PREP
006
1186
LOUNGE
005
200
RETAIL
004
199
FRONT DESK
003
335
LOBBY
002
142
VESTIBULE
001
509
FLEX SEATING
019
99
MAINTENANCE
017
141
LINEN STORAGE
025
703
LAUNDRY
024
350
EMPLOYEEBREAKROOM
027
58
EMPLOYEE RR
030
101
DRYER
026
361
WORK AREA
032
62
RETAIL STORAGE
031
142
PBX
033
187
WATER HEATERS
036
104
GM
035
104
SALES
034
36
MECH
029
ELEVATOR CAB 1
020
ELEVATOR CAB 2
021
110
STORAGE
161
1426
CORRIDOR
139
183
STAIR 2
138
165
STAIR 1
137
638
PATIO
040
530
H2-KING ONEBEDROOM
101 332
HI-QQ STUDIO
104
373
HI-KS-ADA
105
332
HI-KING STUDIO
107
332
HI-QQ STUDIO
108
319
HI-QQ STUDIO
109
332
HI-QQ STUDIO
106
163
ELEV. LOBBY
150
46
VEST.
142
WN61WR60 WN61 WN61 WN61 WD61
WN61WN61
WN61
WN61 WN61
1A401
1
A403
1A402
1A441 603
SHARED SERVING
037
137
MECHANICAL
016
103
VEST.
141
177
ELECTRICAL
028
100
POOL RESTROOM
011
WD61
WD61
WD61
WD61
WD61WD61
WD61
WD61
20 20
18
18
18181818S5
WD61
HI-QQ STUDIO
103
ISSUED SETS
01.01.01 TEMPLATE
SHEET:
DRAWN:
CHECKED:
JOB NO:
REVISIONS
DA
T
E
:
PL
O
T
T
E
D
B
Y
:
FIL
E
P
A
T
H
:
8/2
5
/
2
0
2
5
1
2
:
0
1
:
4
4
P
M
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
5
3
2
C
a
l
d
w
e
l
l
I
D
S
a
d
d
l
e
A
v
e
H
i
l
t
o
n
/
2
5
3
2
_
S
a
d
d
l
e
Av
e
_
A
r
c
h
_
R
2
5
_
C
e
n
t
r
a
l
.
r
v
t
A121
SA
D
D
L
E
A
V
E
FL
O
O
R
P
L
A
N
-
L
E
V
E
L
1
En
t
e
r
a
d
d
r
e
s
s
h
e
r
e
-
-
Project Number
SC
H
E
M
A
T
I
C
D
E
S
I
G
N
3/32" = 1'-0"1 LEVEL 1 FLOOR PLAN
REV#DATE DESCRIPTION
NORTH
DN
UP
DN
UP
A2012
A201
A202
A202
1
2
3
1
A301
1
A301
1
1
2
2
3
3
AA
DD
GG
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
EE
2'
-
4
"
27
'
-
9
1
/
4
"
6'
-
0
1
/
4
"
20
'
-
8
7
/
8
"
7'
-
0
3
/
8
"
8'
-
4
"
17
17
18
18
19
19
BB
CC
20
20
21
21
22
22
23
23
FF
2
A301
2
A301
4
A302
3
A302
2
A302
1
A302
72
'
-
2
3
/
4
"
279'-7 7/8"
4'-0"12'-8"12'-8"12'-8"12'-8"12'-8"12'-8"12'-8"12'-8"12'-8"12'-8"12'-8"17'-4"13'-3"13'-3"13'-3"13'-3"13'-3"13'-3"13'-3"13'-3"12'-11 7/8"
1A485 1A486
1
A484
1A4811A482
1A483
H2-QQS-ADA
201
H2-QQ STUDIO
203 H2-QQ STUDIO
205
H2-QQ STUDIO
207 H2-QQ STUDIO
209
H2-QQ STUDIO
211 H2-QQ STUDIO
213
H2-QQ STUDIO
215
H2-KING STUDIO
204
H2-KING STUDIO
206 H2-KING STUDIO
208
H2-KING STUDIO
210
H2-KING STUDIO
212
H2-KING STUDIO
214
H2-KING STUDIO
216 H2-KING STUDIO
218
H2-KING STUDIO
220
HI-QQ STUDIO
224
ELEV. LOBBY
250
HI-QQS-ADA
222
HI-QQ STUDIO
226
HI-QQ STUDIO
228
HI-QQ STUDIO
230
HI-QQ STUDIO
232
HI-QQ STUDIO
234
HI-QQ STUDIO
236
HI-QQ STUDIO
238
HI-QQ STUDIO
240
B.O.H.
223
HI-QQ STUDIO
227
HI-QQ STUDIO
229 HI-QQ STUDIO
231
HI-QQ STUDIO
233 HI-KS-ADA
235
HI-KING STUDIO
237
H2-KING ONEBEDROOM
202
ELEVATOR CAB 1
020
ELEVATOR CAB 2
021
CORRIDOR
239
STAIR 1
200
STAIR 2
239
STORAGE
261WN61WN61WN61WN61WN61WN61WN61WN61
WN61WN61
WN61
WN61 WN61 WN61 WN61 WN61
WN61
WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61
H2-QQ STUDIO
217 HI-QQ STUDIO
225WN61
WN61WN61
WX62
WX62
WR60
WP61
WA61 WA61 WA61
20 20 20 20 20 20 20
20 20
W3 18 18 18 18
1818181818181818
20202020202020202020
WD61
WD61
WD61
WD61
WD61
WD61
WD61
WD61
WD61
W3
H2-KING ONEBEDROOM ADA
219
GENERAL NOTES: FLOOR PLAN
1.
2.
3.
4.
5.
6.
7.
8.
REFER TO 'G' SHEET GENERAL NOTES FOR DIMENSIONING, GRAPHIC, ABBREVIATIONS AND OTHER STANDARDS.REFER TO LANDSCAPE AND CIVIL DRAWINGS FOR GRADING AND SITE ELEMENTS ADJACENT TO BUILDING.TYP HINGE SIDE DOOR JAMB OFFSET DIMENSION NEAR ADJACENT WALLS SHALL BE 4" TO ROUGH OPENING U.N.O. (8" IN MASONRY WALLS - IF USED)REF. INDIVIDUAL UNIT, AND ENLARGED FLOOR PLANS FOR ADDITIONAL NOTES, DIM'S AND INFORMATION .SLAB PENETRATIONS AND OPENINGS ARE SHOWN SCHEMATICALLY ONLY, GENERAL CONTRACTOR TO COORDINATE THE SIZES AND LOCATIONS OF ALL DUCTS, PIPES, CONDUITS, CHASES AND OTHER OPENINGS WITH THE STRUCTURAL ENGINEER AND/OR ANY DESIGN-BUILD COMPONENT ENGINEER. ANY DEVIATIONS OR DISCREPANCIES AFFECTING THE DIMENSIONING OR VISUAL/SPATIAL DESIGN OF THESE DRAWINGS MAY NOT OCCUR WITHOUT NOTIFICATION AND ACCEPTANCE OF ARCHITECT.WALL ASSEMBLY TYPE TAGS APPLY TO THE FULL LENGTH OF CONTINUOUS WALLS INCLUDING OFFSETS AND AROUND CORNERS UNLESS INDICATED OTHERWISE.WALL ASSEMBLY TYPES DO NOT CONTAIN COMPLETE EXTERIOR CLADDING OR INTERIOR TRIM INFORMATION. REF. ELEVATIONS, FINISH SCHEDULE, AND DETAILS FOR ADDITIONAL INFORMATION.ELEVATION REFERENCES INDICATE TOP OF FINISH UNLESS NOTED OTHERWISE.
ISSUED SETS
01.01.01 TEMPLATE
SHEET:
DRAWN:
CHECKED:
JOB NO:
REVISIONS
DA
T
E
:
PL
O
T
T
E
D
B
Y
:
FIL
E
P
A
T
H
:
8/2
5
/
2
0
2
5
1
2
:
0
1
:
4
6
P
M
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
5
3
2
C
a
l
d
w
e
l
l
I
D
S
a
d
d
l
e
A
v
e
H
i
l
t
o
n
/
2
5
3
2
_
S
a
d
d
l
e
Av
e
_
A
r
c
h
_
R
2
5
_
C
e
n
t
r
a
l
.
r
v
t
A122
SA
D
D
L
E
A
V
E
FL
O
O
R
P
L
A
N
-
L
E
V
E
L
2
En
t
e
r
a
d
d
r
e
s
s
h
e
r
e
-
-
Project Number
SC
H
E
M
A
T
I
C
D
E
S
I
G
N
3/32" = 1'-0"1 LEVEL 2 FLOOR PLAN
REV#DATE DESCRIPTION
NORTH
DNUP
DN
UP
GENERAL NOTES: FLOOR PLAN
1.
2.
3.
4.
5.
6.
7.
8.
REFER TO 'G' SHEET GENERAL NOTES FOR DIMENSIONING, GRAPHIC, ABBREVIATIONS AND OTHER STANDARDS.REFER TO LANDSCAPE AND CIVIL DRAWINGS FOR GRADING AND SITE ELEMENTS ADJACENT TO BUILDING.TYP HINGE SIDE DOOR JAMB OFFSET DIMENSION NEAR ADJACENT WALLS SHALL BE 4" TO ROUGH OPENING U.N.O. (8" IN MASONRY WALLS - IF USED)REF. INDIVIDUAL UNIT, AND ENLARGED FLOOR PLANS FOR ADDITIONAL NOTES, DIM'S AND INFORMATION .SLAB PENETRATIONS AND OPENINGS ARE SHOWN SCHEMATICALLY ONLY, GENERAL CONTRACTOR TO COORDINATE THE SIZES AND LOCATIONS OF ALL DUCTS, PIPES, CONDUITS, CHASES AND OTHER OPENINGS WITH THE STRUCTURAL ENGINEER AND/OR ANY DESIGN-BUILD COMPONENT ENGINEER. ANY DEVIATIONS OR DISCREPANCIES AFFECTING THE DIMENSIONING OR VISUAL/SPATIAL DESIGN OF THESE DRAWINGS MAY NOT OCCUR WITHOUT NOTIFICATION AND ACCEPTANCE OF ARCHITECT.WALL ASSEMBLY TYPE TAGS APPLY TO THE FULL LENGTH OF CONTINUOUS WALLS INCLUDING OFFSETS AND AROUND CORNERS UNLESS INDICATED OTHERWISE.WALL ASSEMBLY TYPES DO NOT CONTAIN COMPLETE EXTERIOR CLADDING OR INTERIOR TRIM INFORMATION. REF. ELEVATIONS, FINISH SCHEDULE, AND DETAILS FOR ADDITIONAL INFORMATION.ELEVATION REFERENCES INDICATE TOP OF FINISH UNLESS NOTED OTHERWISE.
H2-QQS-ADA
301
H2-QQ STUDIO
303 H2-QQ STUDIO
305
H2-QQ STUDIO
307 H2-QQ STUDIO
309
H2-QQ STUDIO
311
H2-QQ STUDIO
313
H2-QQ STUDIO
315
H2-KING STUDIO
304
H2-KING STUDIO
306
H2-KING STUDIO
308 H2-KING STUDIO
310
H2-KING STUDIO
312 H2-KING STUDIO
314
H2-KING STUDIO
316
H2-KING STUDIO
318 H2-KING STUDIO
320
ELEV. LOBBY
350
HI-QQ STUDIO
324
HI-QQS-ADA
322
B.O.H.
323
HI-QQ STUDIO
326
HI-QQ STUDIO
327
HI-QQ STUDIO
328
HI-QQ STUDIO
329
HI-QQ STUDIO
330
HI-QQ STUDIO
331
HI-QQ STUDIO
332
HI-QQ STUDIO
333
HI-QQ STUDIO
334
HI-KS-ADA
335
HI-QQ STUDIO
336
HI-KING STUDIO
337
HI-QQ STUDIO
338
HI-QQ STUDIO
340
H2-KING ONEBEDROOM
302
ELEVATOR CAB 1
020
ELEVATOR CAB 2
021
STAIR 1
337
STAIR 2
338
STORAGE
361
H2-QQ STUDIO
317 HI-QQ STUDIO
325
WN61 WN61 WN61 WN61 WN61 WN61 WN61 WN61
WN61WN61
WN61
WN61 WN61 WN61 WN61 WN61 WN61
WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61
WN61 WN61WN61
WX62
WX62
WR60
WP61
CORRIDOR
339
20 20 20 20 20 20 20
20 20
W3 18 18 18 18
1818181818181818
20202020202020202020
W3
20 20
18 18
18
20
WD61
WD61
WD61
WD61
WD61
WD61
WD61
WD61
WD61
WD61
WD61
H2-KING ONEBEDROOM ADA
319
ISSUED SETS
01.01.01 TEMPLATE
SHEET:
DRAWN:
CHECKED:
JOB NO:
REVISIONS
DA
T
E
:
PL
O
T
T
E
D
B
Y
:
FIL
E
P
A
T
H
:
8/2
5
/
2
0
2
5
1
2
:
0
1
:
4
8
P
M
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
5
3
2
C
a
l
d
w
e
l
l
I
D
S
a
d
d
l
e
A
v
e
H
i
l
t
o
n
/
2
5
3
2
_
S
a
d
d
l
e
Av
e
_
A
r
c
h
_
R
2
5
_
C
e
n
t
r
a
l
.
r
v
t
A123
SA
D
D
L
E
A
V
E
FL
O
O
R
P
L
A
N
-
L
E
V
E
L
3
En
t
e
r
a
d
d
r
e
s
s
h
e
r
e
-
-
Project Number
SC
H
E
M
A
T
I
C
D
E
S
I
G
N
REV#DATE DESCRIPTION
3/32" = 1'-0"1 LEVEL 3 FLOOR PLAN NORTH
DN
DN
GENERAL NOTES: FLOOR PLAN
1.
2.
3.
4.
5.
6.
7.
8.
REFER TO 'G' SHEET GENERAL NOTES FOR DIMENSIONING, GRAPHIC, ABBREVIATIONS AND OTHER STANDARDS.REFER TO LANDSCAPE AND CIVIL DRAWINGS FOR GRADING AND SITE ELEMENTS ADJACENT TO BUILDING.TYP HINGE SIDE DOOR JAMB OFFSET DIMENSION NEAR ADJACENT WALLS SHALL BE 4" TO ROUGH OPENING U.N.O. (8" IN MASONRY WALLS - IF USED)REF. INDIVIDUAL UNIT, AND ENLARGED FLOOR PLANS FOR ADDITIONAL NOTES, DIM'S AND INFORMATION .SLAB PENETRATIONS AND OPENINGS ARE SHOWN SCHEMATICALLY ONLY, GENERAL CONTRACTOR TO COORDINATE THE SIZES AND LOCATIONS OF ALL DUCTS, PIPES, CONDUITS, CHASES AND OTHER OPENINGS WITH THE STRUCTURAL ENGINEER AND/OR ANY DESIGN-BUILD COMPONENT ENGINEER. ANY DEVIATIONS OR DISCREPANCIES AFFECTING THE DIMENSIONING OR VISUAL/SPATIAL DESIGN OF THESE DRAWINGS MAY NOT OCCUR WITHOUT NOTIFICATION AND ACCEPTANCE OF ARCHITECT.WALL ASSEMBLY TYPE TAGS APPLY TO THE FULL LENGTH OF CONTINUOUS WALLS INCLUDING OFFSETS AND AROUND CORNERS UNLESS INDICATED OTHERWISE.WALL ASSEMBLY TYPES DO NOT CONTAIN COMPLETE EXTERIOR CLADDING OR INTERIOR TRIM INFORMATION. REF. ELEVATIONS, FINISH SCHEDULE, AND DETAILS FOR ADDITIONAL INFORMATION.ELEVATION REFERENCES INDICATE TOP OF FINISH UNLESS NOTED OTHERWISE.
H2-KS-ADA
401
H2-QQ STUDIO
403 H2-QQ STUDIO
405
H2-QQ STUDIO
407 H2-QQ STUDIO
409
H2-QQ STUDIO
411 H2-QQ STUDIO
413
H2-QQ STUDIO
415
H2-KING STUDIO
404
H2-KING STUDIO
406
H2-KING STUDIO
408 H2-KING STUDIO
410
H2-KING STUDIO
412
H2-KING STUDIO
414
H2-KING STUDIO
416 H2-KING STUDIO
418
H2-KING STUDIO
420
ELEV. LOBBY
450
HI-QQ STUDIO
424
HI-QQS-ADA
422
B.O.H.
423
HI-QQ STUDIO
426
HI-QQ STUDIO
427
HI-QQ STUDIO
428
HI-QQ STUDIO
429
HI-QQ STUDIO
430
HI-QQ STUDIO
431
HI-QQ STUDIO
432
HI-QQ STUDIO
433
HI-QQ STUDIO
434
HI-KS-ADA
435
HI-QQ STUDIO
436
HI-KING STUDIO
437
HI-QQ STUDIO
438
HI-QQ STUDIO
440
H2-KING ONEBEDROOM
402
ELEVATOR CAB 1
020
ELEVATOR CAB 2
021
STAIR 1
437
STAIR 2
438
STORAGE
461
HI-QQ STUDIO
425
H2-QQ STUDIO
417
CORRIDOR
439
20 20 20 20 20 20 20
20 20
W3 18 18 18 18
1818181818181818
20202020202020202020
W3
20 20
18 18
18
20
WD61
WD61
WD61
WD61
WD61
WD61
WD61
WD61
WD61
WD61
WN61 WN61 WN61 WN61 WN61 WN61 WN61 WN61
WN61WN61
WN61
WN61 WN61 WN61 WN61 WN61
WN61
WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61WN61
WN61 WN61WN61
WX62
WX62
WR60
WP61
WD61
WD61
WD61
WD61
WD61
WD61
WD61
WD61
WD61
WD61
WD61 H2-KING ONEBEDROOM ADA
419
ISSUED SETS
01.01.01 TEMPLATE
SHEET:
DRAWN:
CHECKED:
JOB NO:
REVISIONS
DA
T
E
:
PL
O
T
T
E
D
B
Y
:
FIL
E
P
A
T
H
:
8/2
5
/
2
0
2
5
1
2
:
0
1
:
5
1
P
M
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
5
3
2
C
a
l
d
w
e
l
l
I
D
S
a
d
d
l
e
A
v
e
H
i
l
t
o
n
/
2
5
3
2
_
S
a
d
d
l
e
Av
e
_
A
r
c
h
_
R
2
5
_
C
e
n
t
r
a
l
.
r
v
t
A124
SA
D
D
L
E
A
V
E
FL
O
O
R
P
L
A
N
-
L
E
V
E
L
4
En
t
e
r
a
d
d
r
e
s
s
h
e
r
e
-
-
Project Number
SC
H
E
M
A
T
I
C
D
E
S
I
G
N
REV#DATE DESCRIPTION
3/32" = 1'-0"1 LEVEL 4 FLOOR PLAN NORTH
1.
A.
REFER TO 'G' SHEET GENERAL NOTES FOR DIMENSIONING, GRAPHIC, ABBREVIATIONS AND OTHER STANDARDS.
2.FOR TYPICAL ROOF ASSEMBLIES REFER TO SHEET AX/ XXX
3.FOR TYPICAL ROOF PENETRATION DETAILS REFER TO SHEET ###.
4.FOR ADDITIONAL ROOF PENETRATION DETAILS: REFER TO MEP DOCS.
5.MECHANICAL, ELECTRICAL AND PLUMBING ROOF EQUIPMENT DEPICTED ON THIS SHEET IS FOR GENERAL ARCHITECTURAL INFORMATION ONLY. REFER MEP DOCUMENTS FOR ROOFTOP EQUIPMENT NOT SHOWN AND FOR ADDITIONAL REQUIREMENTS AND COORDINATION. REFER STRUCTURAL DOCUMENTS FOR EQUIPMENT SUPPORTS. REFER SHEET ### AND MEP AND STRUCT DOCS FOR CURB DETAILS.
6.SHEET ### FOR TYPICAL PIPE SUPPORT DETAIL.
7.PROVIDE WALKWAY PAD AT PIPE SUPPORT LOCATIONS. REFER MEP DOCS FOR PIPE SUPPORTS LOCATION AND TYPE. PAD SHALL BE MIN 2" WIDER THAN SUPPORT IN ALL DIRECTIONS.
8.PROVIDE CONT 36" WIDE WALKWAY BOARDS AT SERVICE SIDE OF ALL MECH EQUIP WITH 2" SEPARATIONS BETWEEN PADS. REFER TO MEP DOCS FOR NUMBER AND LOCATION OF ROOFTOP MECH EQUIP. PROVIDE CONT 36" WIDE WALKWAY BOARDS AROUND ROOF HATCHES WITH 2" SEPARATIONS BETWEEN PADS, AND PROVIDE 72"x72" WALKWAY BOARDS AT TOP AND BOTTOM OF ACCESS LADDERS.
9.EXPOSED METAL FLASHING/ TRIM PIECES ARE TO BE PREFIN GALV STL, U.N.O. PAINT EXPOSED METAL FLASHING/ TRIM PIECES THAT ARE NOT PREFIN, AS WELL AS ALL EXPOSED MISC STL PIECES. REFER COLOR SCHEDULE AND NOTES, SHEET AF 6.01.
10.GUTTERS SHALL BE PREFINISHED GALV STL (GUTTER SIZES PER ROOF LEGEND), U.N.O. PROVIDE PNT 1/4 x 1 1 2" GALV STL BENT PLATE BRACKETS AND 1" GALV STL SPACERS AT 36"OC MAX, - STAGGER W/ EACH OTHER AT 18"OC. PROVIDE PREFIN GUTTER EJ's. PROVIDE SST SCREENS AT ALL GUTTERS. LOCATE GUTTER EJ's PER ROOF PLAN, (30' MAX SPAN).
11.TAPERED INSULATION SHALL BE 1/ 4"/ FT MIN SLOPE TO DRAIN. ROOF PLAN SHOWS TAPERED INSUL IS N.T.S. AND IS GRAPHIC ONLY FOR GENERAL SLOPE AND APPROX LOCATION. (VERIFY INSULATION REQUIRED TO MAINTAIN SLOPE, PRIOR TO INSTALLATION).
12.PROVIDE TAPERED INSULATION CRICKETS (1/4" / FT MIN SLOPE) AT HIGH SIDE OF ALL MECH UNITS, AND MISC ROOF PENETRATIONS, TO SHED WATER AROUND, AND TO INSURE POSITIVE ROOF DRAINAGE.
13.WOOD BLOCKING AT ROOF EDGES, RIDGES, ETC SHALL BE FABRICATED FROM CONTINUOUS MIN. 2x6s P.T. WOOD BLOCKING. PROVIDE LARGER 2x P.T. WOODS REQUIRED PER DETAIL DIMENSIONS. REFER ROOFING MANF RECOMMENDATIONS.
14.WHERE WOOD BLOCKING EXCEEDS 6" THICKNESS AT TAPERED INSULATION, PROVIDE STEM WALL CONSTRUCTED OF 6" GALV. C.F.M.F. AT 16"OC W/ CONTINUOUS TRACK TOP AND BOTTOM AND W/ 3/ 4" PT EXTERIOR GRADE PLYWOOD AT EACH SIDE, TOP TO SLOPE W/ TAPERED INSULATION. DET REFER ###.
15.PROVIDE STEP FLASHING AND COVER PLATE AT SLOPED ROOF HI/ LO CONDITIONS. REFER DET ###.
16.VERIFY ELEVATION OF ROOF DRAIN RELATIVE TO OVERFLOW SCUPPER PRIOR TO INSTALLATION OF SCUPPERS. REFER DET ###.
17.LOCATE SCUPPERS AS INDICATED ON ELEVATIONS, EITHER CENTERED OVER WINDOWS/ OPENINGS, OR CENTERED BETWEEN WINDOWS/ OPENINGS, U.N.O..AT MASONRY LOCATIONS ADJUST PLACEMENT TO MEET MASONRY COURSING MODULES.
18.PROVIDE ROOF AREA DIVIDER. REFER DET ###.
19.STRUCTURAL SLOPES SHOWN ON PLAN ARE FOR GENERAL CONCEPT ONLY. REFER STRUCTURAL DRAWINGS FOR EXACT T.O.S./ B.O.D. ELEVATIONS. WHERE ROOF SLOPE EXCEEDS 1/2"PER FOOT, INSTALL ROOFING MEMBRANE SHEETS PARALLEL WITH SLOPE.
20.ALL INTERNAL GUTTERS SHALL BE FULLY WELDED GALV STEEL, SIZED AS INDICATED ON THE DRAWINGS. GUTTERS SHALL BE WATER TESTED IN ACCORDANCE WITH OWNER REQUIREMENTS - COORDINATE W/ ARCHITECT.
21.REFER PLUMBING DOCUMENTS FOR ROOF DRAIN LEADERS, CONNECTIONS TO STORM DRAIN, AND NOZZLES.
22.PROVIDE OVERFLOW SCUPPERS AT EACH ROOF DRAIN INDICATED ON THE DRAWINGS. REFER ROOF PLAN AND BUILDING ELEVATIONS FOR LOCATIONS.
23.FLASHING AND STRIPPING MATERIALS, BASE PLY SHEETS, AUXILIARY MEMBRANES, INSULATION, AND ACCESSORIES SHOULD BE RECOMMENDED BY THE ROOFING SYSTEM MANUFACTURER FOR INTENDED USE AND COMPATIBILITY WITH THE MEMBRANE ROOFING SYSTEM U.N.O.
24.PROVIDE STANDARD EAVE CLOSURES, AND MISC TRIM REQUIRED FOR COMPLETE ASSEMBLY.
25.PAINT ALL EXPOSED METAL FLASHING THAT IS NOT PREFINISHED REF TO COLOR SCHEDULE AND NOTES.
26.ALL EXHAUST FANS AND WASTE VENTS TO BE A MIN. OF 25’ (TWENTY-FIVE FEET) FROM INTAKE ON ALL MAKE-UP UNITS ON ROOF.
27.SUPPLY AND RETURN TO MECHANICAL UNITS TO BE CLEAR OF OBSTRUCTION AT ALL TIMES (FIELD VERIFY AND COORDINATE WITH STEEL CONTRACTOR PRIOR TO SETTING UNITS).
28.NO ROOF PENETRATIONS SHALL BE ALLOWED CLOSER THAN 12” TO ANOTHER PENETRATION.
29.FOR TYPICAL ROOF PENETRATION DETAILS: PROVIDE MEMBRANE ROOF MFRS STANDARD ROOF CURBS AND PENETRATION DETAILS. FOR LOCATIONS, WEIGHTS, AND ANY OTHER ADDITIONAL INFO REF TO MEP DOCS. COORDINATE FINAL SIZE W/ MEP CONTRACTOR.
PROVIDE CURBS AND SUPPORTS NOT INDICATED ON THE STRUCTURAL DOCUMENTS FOR ROOF TOP MECH EQUIPMENT, INCLUDING BUT NOT LIMITED TO R.T.U.S, CONDENSERS, AND FANS. REFER STRUCTURAL AND MEP DOCUMENTS.
B.PROVIDE SUPPORTS AND FLASHING AS REQUIRED AT GAS PIPING ON THE ROOF AS INDICATED.
PM TO REVIEW AND EDIT
GENERAL NOTES: ROOF PLAN
1
A301
1
1
2
2
3
3
AA
DD
GG
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
EE
17
17
18
18
19
19
BB
CC
20
20
21
21
22
22
23
23
FF
2
A301
4
A302
3
A302
2
A302
1
A302
4'-0"12'-8"12'-8"12'-8"12'-8"12'-8"12'-8"12'-8"12'-8"12'-8"12'-8"12'-8"17'-4"13'-3"13'-3"13'-3"13'-3"13'-3"13'-3"13'-3"13'-3"12'-11 7/8"
279'-7 7/8"
72
'
-
2
3
/
4
"
2'
-
4
"
27
'
-
9
1
/
4
"
6'-
0
1
/
4
"
20
'
-
8
7
/
8
"
7'-
0
3
/
8
"
8'
-
4
"
ISSUED SETS
01.01.01 TEMPLATE
SHEET:
DRAWN:
CHECKED:
JOB NO:
REVISIONS
DA
T
E
:
PL
O
T
T
E
D
B
Y
:
FIL
E
P
A
T
H
:
8/2
5
/
2
0
2
5
1
2
:
0
1
:
5
3
P
M
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
2
5
3
2
C
a
l
d
w
e
l
l
I
D
S
a
d
d
l
e
A
v
e
H
i
l
t
o
n
/
2
5
3
2
_
S
a
d
d
l
e
Av
e
_
A
r
c
h
_
R
2
5
_
C
e
n
t
r
a
l
.
r
v
t
A141
SA
D
D
L
E
A
V
E
RO
O
F
P
L
A
N
En
t
e
r
a
d
d
r
e
s
s
h
e
r
e
-
-
Project Number
SC
H
E
M
A
T
I
C
D
E
S
I
G
N
3/32" = 1'-0"1 ROOF PLAN
REV#DATE DESCRIPTION
PM/PA NOTE: SHOW WALKING PATH ON SINGLE-PLY MEMBRANE ROOF