HomeMy WebLinkAboutAPPROVED_LandscapePlan_HomeDepotR/WOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHTOHTOHTOHTOHTOHTOHTOHTOHTOHTOHTOHTOHTOHTOHTOHTRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDEPEPEPEPEPRENTALRENTAL RENTALRENTALRENTAL RENTAL
EV PARKINGVANVAN
SANSANSANSANSTOPYIELDYIELDCOCOCO
STOPSTOP
UGP UGP UGP SANSANYIELDYIELDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVEDRESERVED LOAD-N-GOLOAD-N-GO
EPEPEPEPEP
EPGMTRSDSTOPSTOPSTOPSDMWMWMWMWMWSDSDSDSDSDMTRMTR STOPMWSDSDBUILDING: 107,516 SF(28,157 SF)GARDEN CENTERTHE HOME DEPOTRESERVEDEPSDSDSDSDFSWTR
EV PARKING60' N0 BUILD ZONEJF (3)JB (3)VD (6)BG (3)(1) GS(2) TC(1) GS(1) GS(1) GSAO (1)(3) AO(6) VD(12) HH(1) SG(1) JB(8) HH(6) BG(1) GS(3) VD(1) JB(1) SG(6) JB(6) JF(3) TC(4) HH(4) SG(4) JBAO (3)(1) JB(1) SG(6) JB(3) TC(6) JF(4) HH(1) JB(1) SG(3) AO(6) VD(12) HH(3) BG(1) GS(2) JF(12) HHHH (12)JB (5)GS (1)JF (2)(1) GS(2) JF(12) HH(2) JF(1) GS(5) JB(12) HH(3) SG(1) TC(4) JB(1) GS(2) JF(12) HH(1) GS(2) VD(2) SG(3) SG(1) TC(4) JB(12) HH(1) GS(2) JF(2) JF(1) GS(12) HH(1) GS(2) VD(2) SG(1) GS(2) JF(12) HHSG (3)JB (2)(2) JB(1) TC(3) SGTC (1)JB (2)SG (2)(2) SG(2) JB(1) TC(2) JF(1) GS(12) HH(1) GS(2) VD(2) SG(1) GS(6) HH(2) JF(1) GS(12) HH(1) GS(2) VD(2) SG(1) GS(2) JF(12) HH(3) SG(4) JB(1) GS(2) VD(2) SG(1) GS(2) VD(2) SG(2) VD(2) SG(2) VD(2) SG(1) ZS(1) ZS(1) GS(2) JF(12) HH(12) HH(1) ZS(2) JF(3) JF(5) JB(1) GS(12) HH(1) GS(2) JF(12) HH(2) JF(1) GS(12) HH(1) TC(3) SG(4) JB(1) ZS(2) JF(12) HH(2) JF(12) HH(2) GS(7) JB(12) HH(2) GS(2) JF(1) GS(2) VD(2) SG(1) GS(2) VD(2) SG(1) TC(3) SG(4) JB(1) TC(3) SG(4) JBZS (3)(1) ZS(1) ZS(1) ZS111US HWY 20 / 26 (CHINDEN BLVD.) (PUBLIC)(4) SG(24) HH(5) JB5
L1.2 (2) JF(3) AOPG (5)AO (3)PG (5)AO (1)(3) SG(6) SGSG (6)(6) SG(6) SG(6) BGHH (12)Keynotes:1.VISION TRIANGLE PER CALDWELL CITY CODE.2.SAVE AND PROTECT EXISTING TREES. SEE TREE PROTECTION NOTES THIS SHEET.CALLOUT NUMBERS COORDINATEDTO NUMBERED NOTES BELOW.Legend:CODEBOTANICAL / COMMON NAMESIZECONTAINERREMARKSTREESAOACER RUBRUM 'OCTOBER GLORY' / OCTOBER GLORY RED MAPLE2" CAL.B&B50'H X 40'WGSGLEDITSIA TRIACANTHOS INERMIS 'SKYLINE' / SKYLINE HONEY LOCUST2" CAL.B&B45'H X 35'WPGPICEA PUNGENS 'GLAUCA' / BLUE COLORADO SPRUCE6` HT.B&B50'H X 20'WTCTILIA CORDATA / LITTLELEAF LINDEN2" CAL.B&B60'H X 40'WZSZELKOVA SERRATA 'SCHMIDTLOW' / WIRELESS® JAPANESE ZELKOVA2" CAL.B&B24'H X 36'WSHRUBSBGBUXUS X 'GREEN VELVET' / GREEN VELVET BOXWOOD3 GAL.POT4'H X 4'WHHHEMEROCALLIS X 'HAPPY RETURNS' / HAPPY RETURNS DAYLILY2 GAL.POT2'H X 2'WJBJUNIPERUS CONFERTA 'BLUE PACIFIC' / BLUE PACIFIC SHORE JUNIPER2 GAL.POT1'H X 6'WJFJUNIPERUS CHINENSIS 'SEA GREEN' / SEA GREEN JUNIPER2 GAL.POT5'H X 7'WSGSPIRAEA JAPONICA 'GOLDFLAME' / GOLDFLAME JAPANESE SPIREA3 GAL.POT3'H X 4'WVDVIBURNUM DENTATUM 'ARROWWOOD' / ARROWWOOD VIBURNUM5 GAL.POT8'H X 8'WPLANT SCHEDULELandscape Notes:A.PROTECT THE CRITICAL ROOT ZONE OF THE TREES TO BE RETAINED ON SITE: (NOTE: CRITICAL ROOT ZONE IS THE AREADIRECTLY BELOW THE DRIP LINE OF THE TREE.)A.A.CONSTRUCT PROTECTIVE FENCING OF CHAIN-LINK AROUND THE CRITICAL ROOT ZONE PRIOR TO DEMOLITION ORCONSTRUCTION.A.B.DO NOT ALLOW COMPACTION BY EQUIPMENT TRAFFIC DURING CONSTRUCTION OR DURING DEMOLITION.A.C.DO NOT ALLOW CEMENT TRUCKS TO RINSE WITHIN THE PROTECTION AREA, ANYWHERE THAT TREE ROOTS EXIST OR INPLANNED PLANTING BEDS.A.D.DO NOT STOCKPILE MATERIALS, DEBRIS OR DIRT WITHIN THE TREE PROTECTION AREA.A.E.MAINTAIN WATERING WITHIN THE CRITICAL ROOT ZONE FROM MID-APRIL TO MID-OCTOBER AT THE RATE OF NOT LESSTHAN THE EQUIVALENT OF 1-1/2" OF WATER OVER THE ENTIRE AREA PER WEEK.A.F.DO NOT TRENCH, EXCAVATE, FILL OR OTHERWISE DISTURB THE SOIL WITHIN THE CRITICAL ROOT ZONE.A.G.ADJUST PROPOSED IMPROVEMENT LOCATIONS AS REQUIRED TO AVOID DAMAGING TREE ROOTS.B.PROTECT THE CROWN AND TRUNK OF TREES TO BE RETAINED ON SITE:B.A.OPERATE EQUIPMENT IN SUCH A WAY AS TO AVOID CONTACT WITH TREE TRUNKS OR BRANCHES.B.B.PRUNING OF PUBLIC PROPERTY TREES SHALL BE PERFORMED BY A LICENSED ARBORIST.C.ALL TREES DAMAGED OR DESTROYED DURING CONSTRUCTION SHALL BE REPLACED WITH A ONE AND ONE-HALF INCH (1 ½ ")TO THREE INCH (3") CALIPER TREE, RATED AS A #1 QUALITY TREE AND AS VERIFIED BY THE CITY FORESTER. SELECTION OFWHAT SPECIES TO REPLACE WILL COME FROM THE TREE SELECTION GUIDE. IF THERE IS NOT ENOUGH ROOM ON THE SUBJECTSITE TO REPLACE THE CALIPER INCH OF TREES THAT WERE REMOVED, THE DEVELOPER WILL CONTRIBUTE A DOLLAR AMOUNTEQUAL TO THE CORRESPONDING CALIPER INCH OF TREES TO A TREE BANK FOR FUTURE TREE PLANTING. THE CITY MAYCHOOSE WHICH PARK, CEMETERY, OR SITE MOST IN NEED OF TREES.Tree Protection Notes:STREET BUFFERS - CALDWELL CITY CODE SECTION 10-07-0820-FT MIN. BUFFER WIDTH WITH 1 TREE PER 35 L.F. AND 1 SHRUB PER 7 L.F.HIGHWAY 20/26:BUFFER L.F.TREES REQUIRED / PROVIDEDSHRUBS REQUIRED / PROVIDED1,056 L.F. 30 / 32151 / 226SMEED PARKWAY:BUFFER L.F.TREES REQUIRED / PROVIDEDSHRUBS REQUIRED / PROVIDED440 L.F.13 / 13 (3 EXISTING) 74 / 79LAND USE BUFFERS - CALDWELL CITY CODE SECTION 10-07-10MIX OF DECIDUOUS AND EVERGREEN TREES WITH TURF AND SHRUBS.TREES SPACED AT 30' INTERVALS AND SHRUBS SPACED AT 2' & 8' INTERVALS.SOUTH BOUNDARY:BUFFER L.F.TREES PROVIDEDSHRUBS PROVIDED798 L.F. 186TREE MITIGATION NOTEALL TREES INTERNAL TO THE SITE THAT ARE PROPOSED TO BE REMOVED ARE DEAD OR NOT OF HEALTHY CONDITION. NOMITIGATION NECESSARY. ONE WILLOW TREE AND TWO CONIFEROUS TREES ALONG SMEED PARKWAY ARE TO BE REMOVED.MITIGATION METHODS WILL BE TO PROPOSE THREE TREES ALONG THE SOUTH SITE BOUNDARY, PER CITY OF CALDWELLSTANDARDS. SEE DEMOLITION PLAN FOR LOCATIONS OF TREES TO BE REMOVED.Project CalculationsTURF SOD,80:20 KENTUCKYBLUEGRASS: RYE GRASSMEDIUM BARK MULCH,3" DEPTH MINIMUM.SITE PROPERTY LINEPLANTING BED CUT EDGE. SEE DETAIL 4/L1.2.VISION TRIANGLENOTE: DO NOT PLANT ANY TREE SPECIES BUT WIRELESS JAPANESE ZELKOVA DIRECTLY UNDER OVERHEADPOWER LINES. THIS TREE AND PROPOSED LOCATIONS WERE CHOSEN BASED ON HEIGHT RESTRICTIONS.A.CONTRACTOR SHALL REPORT TO LANDSCAPE ARCHITECT ALL CONDITIONS WHICH IMPAIR AND/OR PREVENT THE PROPEREXECUTION OF THIS WORK, PRIOR TO BEGINNING WORK.B.ALL LANDSCAPE AREAS SHALL BE WEED FREE AT THE TIME OF LANDSCAPE INSTALLATION. REMOVE ALL ROOTS, WEEDS,ROCKS AND FOREIGN MATERIAL ON THE SURFACE.C.FINISH GRADES TO BE SMOOTH AND EVEN GRADIENTS WITH POSITIVE DRAINAGE IN ACCORDANCE WITH SITE GRADING PLAN.REMOVE RIDGES AND FILL DEPRESSIONS AS REQUIRED TO MEET FINISH GRADES. FINISH GRADE RELATED TO ADJACENT SITEELEMENTS SHALL BE:C.A.1" BELOW TOP OF ADJACENT PAVEMENT, VALVE BOX, VAULT, ETC.C.B.3" BELOW TOP OF CURB UNLESS NOTED OTHERWISE.D.ALL PLANTING BEDS SHALL BE COVERED WITH A MINIMUM OF 3" OF MEDIUM BARK MULCH. SUBMIT SAMPLE FOR APPROVAL.E.ALL PLANTING BEDS SHALL HAVE A MINIMUM OF 18" OF TOPSOIL, SOD AREAS A MINIMUM OF 12" OF TOPSOIL. SPREAD,COMPACT AND FINE GRADE TOPSOIL TO A SMOOTH AND UNIFORM GRADE.F.RE-USE EXISTING SURFACE TOPSOIL WHERE POSSIBLE. VERIFY SUITABILITY OF SURFACE SOIL TO PRODUCE TOPSOIL MEETINGREQUIREMENTS AND AMEND WHEN NECESSARY. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM; CLEAN AND FREE OFTOXIC MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS OR OTHER FOREIGN MATERIAL AND WITH A PH OF 5.5 TO7.0. IF ON-SITE TOPSOIL DOES NOT MEET THESE MINIMUM STANDARDS, CONTRACTORS ARE RESPONSIBLE TO EITHER: A)PROVIDE APPROVED IMPORTED TOPSOIL, OR B.) IMPROVE ON-SITE TOPSOIL WITH METHODS APPROVED BY LANDSCAPEARCHITECT. SUPPLEMENT WITH IMPORTED TOPSOIL WHEN QUANTITIES ARE INSUFFICIENT. CLEAN TOPSOIL OF ROOTS,PLANTS, SODS, STONES, CLAY LUMPS AND OTHER EXTRANEOUS MATERIALS HARMFUL TO PLANT GROWTH.G.IF IMPORTED TOPSOIL FROM OFF-SITE SOURCES IS REQUIRED PROVIDE NEW TOPSOIL THAT IS FERTILE, FRIABLE, NATURALLOAM SURFACE SOIL REASONABLY FREE OF SUBSOIL, CLAY LUMPS, BRUSH, WEEDS AND OTHER LITTER, AND FREE OF ROOTS,STUMPS, STONES LARGER THAN 2 INCHES IN ANY DIMENSION, AND OTHER EXTRANEOUS MATERIALS HARMFUL TO PLANTGROWTH.H.OBTAIN TOPSOIL FROM LOCAL SOURCES OR FROM AREAS HAVING SIMILAR SOIL CHARACTERISTICS TO THAT FOUND ATPROJECT SITE. OBTAIN TOPSOIL ONLY FROM NATURALLY, WELL-DRAINED SITES WHERE TOPSOIL OCCURS IN A DEPTH OF NOTLESS THAN 4".I.NEW TREE PLANTING, SEE DETAILS 1 & 2/L1.2. CONTRACTOR SHALL STAKE ALL TREES DEEMED NECESSARY, I.E...FROM BEINGBLOWN OVER, PLANTED WITH LOOSE ROOT BALL, ETC. CONTRACTOR'S OPTION.J.NEW SHRUB PLANTING. SEE DETAIL 3/L1.2.K.ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR TYPE AND SIZE SHOWN. PLANTSWILL BE REJECTED IF NOT IN A SOUND AND HEALTHY CONDITION.L.ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING AT THE DATE OF SUBSTANTIALCOMPLETION. REPLACE ALL PLANT MATERIAL FOUND DEAD OR NOT IN A HEALTHY CONDITION IMMEDIATELY WITH THE SAMESIZE AND SPECIES AT NO COST TO THE OWNER.M.IN ALL PLANTER BED AND LAWN AREAS, THE TOP 6 INCHES OF TOPSOIL WILL BE AMENDED AT A RATIO OF 3 CUBIC YARDS OFCOMPOST/ORGANIC MATTER PER 1000 SQUARE FEET. ROTO-TILL ORGANIC MATTER A MINIMUM OF 6" INTO TOPSOIL. ALL TREEPITS SHALL BE A MIX OF SEVEN PARTS TOPSOIL (AS SPECIFIED IN THESE NOTES) AND THREE PARTS COMPOST/ORGANICMATTER, BY VOLUME.N.FERTILIZE ALL TREES AND SHRUBS WITH 'AGRIFORM' PLANTING TABLETS OR APPROVED EQUAL. QUANTITY PERMANUFACTURER'S RECOMMENDATIONS.O.TREE PIT BACKFILL PLANTING MIX: BLEND TOPSOIL AND SOIL AMENDMENTS AND FERTILIZER FOR TREE PIT BACKFILL AT THEFOLLOWING RATES. BLEND AMENDMENTS THOROUGHLY WITH SOIL BACKFILL. TREE PITS SHALL BE 5'x5'x1.5' (37.5 CF/ 1.5 CY).O.A.APPLICATION RATES:O.A.A.HUMIC ACID: 25 LBS PER TREE PITO.A.B.COMMERCIAL GRADE COMPOST - 10 CUBIC FEET PER TREE PITO.A.C.PLANTING TABLET FERTILIZER - 4 TABLETS PER TREE PITO.A.D.CALCIFIED DIATOMACEOUS EARTH - 75 LBS PER TREE PITP.SHRUB PIT BACKFILL PLANTING MIX: BLEND TOPSOIL AND SOIL AMENDMENTS AND FERTILIZER FOR SHRUB PIT BACKFILL AT THEFOLLOWING RATES. BLEND AMENDMENTS WITH THOROUGHLY WITH SOIL BACKFILL. SHRUB PITS SHALL BE 2.5'x2.5'x1' (6.25 CF/0.25 CY).P.A.APPLICATION RATES:P.A.A.HUMIC ACID: 2 LBS PER SHRUB PITP.A.B.COMMERCIAL GRADE COMPOST - 2 CUBIC FEET PER SHRUB PITP.A.C.PLANTING TABLET FERTILIZER - 2 TABLETS PER SHRUB PITP.A.D.CALCIFIED DIATOMACEOUS EARTH - 15 LBS PER SHRUB PITQ.IMMEDIATELY CLEAN UP ANY TOPSOIL OR OTHER DEBRIS ON THE SITE CREATED FROM LANDSCAPE OPERATIONS AND DISPOSEOF PROPERLY OFF SITE.R.IN THE EVENT OF A DISCREPANCY NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY.#2-IN CRUSHED BASALTROCK MULCH, 4" DEPTHMINIMUM.Horizontal Scale: 030'60'1" = 30'Landscape Plan-Area AL1.1 - AREA BL1.1 - AREA BFile Location:g:\2024\124082\cad\_cds\124082 cd l1.0 landscape plan.dwgLast Plotted By:tyler chambersDate Plotted:Sunday, June 22 2025 at 10:36 AM
L1.0Landscape PlanArea ARevisions1.CHANGE BULLETIN #1 - 11/26/24Date of Issuance:Project No.:Project Milestone:----1CONSTRUCTIONNOT FORPERMIT SUBMITTAL09-25-2024124082.00CALDWELL, IDAHO
4106 HWY 20/26
Caldwell, Idaho
Home Depot - Store #____2.CHANGE BULLETIN #2 - 2/28/253.CHANGE BULLETIN #3 - 5/5/254. CITY COMMENTS - 6/23/25CC44CC44CC44CC44CC44CC44CC44CC44CC44
Keynotes:1.VISION TRIANGLE PER CALDWELL CITY CODE.2.SAVE AND PROTECT EXISTING TREES. SEE TREE PROTECTION NOTES THIS SHEET.CALLOUT NUMBERS COORDINATEDTO NUMBERED NOTES BELOW.Legend:CODEBOTANICAL / COMMON NAMESIZECONTAINERREMARKSTREESAOACER RUBRUM 'OCTOBER GLORY' / OCTOBER GLORY RED MAPLE2" CAL.B&B50'H X 40'WGSGLEDITSIA TRIACANTHOS INERMIS 'SKYLINE' / SKYLINE HONEY LOCUST2" CAL.B&B45'H X 35'WPGPICEA PUNGENS 'GLAUCA' / BLUE COLORADO SPRUCE6` HT.B&B50'H X 20'WTCTILIA CORDATA / LITTLELEAF LINDEN2" CAL.B&B60'H X 40'WZSZELKOVA SERRATA 'SCHMIDTLOW' / WIRELESS® JAPANESE ZELKOVA2" CAL.B&B24'H X 36'WSHRUBSBGBUXUS X 'GREEN VELVET' / GREEN VELVET BOXWOOD3 GAL.POT4'H X 4'WHHHEMEROCALLIS X 'HAPPY RETURNS' / HAPPY RETURNS DAYLILY2 GAL.POT2'H X 2'WJBJUNIPERUS CONFERTA 'BLUE PACIFIC' / BLUE PACIFIC SHORE JUNIPER2 GAL.POT1'H X 6'WJFJUNIPERUS CHINENSIS 'SEA GREEN' / SEA GREEN JUNIPER2 GAL.POT5'H X 7'WSGSPIRAEA JAPONICA 'GOLDFLAME' / GOLDFLAME JAPANESE SPIREA3 GAL.POT3'H X 4'WVDVIBURNUM DENTATUM 'ARROWWOOD' / ARROWWOOD VIBURNUM5 GAL.POT8'H X 8'WPLANT SCHEDULELandscape Notes:A.PROTECT THE CRITICAL ROOT ZONE OF THE TREES TO BE RETAINED ON SITE: (NOTE: CRITICAL ROOT ZONE IS THE AREADIRECTLY BELOW THE DRIP LINE OF THE TREE.)A.A.CONSTRUCT PROTECTIVE FENCING OF CHAIN-LINK AROUND THE CRITICAL ROOT ZONE PRIOR TO DEMOLITION ORCONSTRUCTION.A.B.DO NOT ALLOW COMPACTION BY EQUIPMENT TRAFFIC DURING CONSTRUCTION OR DURING DEMOLITION.A.C.DO NOT ALLOW CEMENT TRUCKS TO RINSE WITHIN THE PROTECTION AREA, ANYWHERE THAT TREE ROOTS EXIST OR INPLANNED PLANTING BEDS.A.D.DO NOT STOCKPILE MATERIALS, DEBRIS OR DIRT WITHIN THE TREE PROTECTION AREA.A.E.MAINTAIN WATERING WITHIN THE CRITICAL ROOT ZONE FROM MID-APRIL TO MID-OCTOBER AT THE RATE OF NOT LESSTHAN THE EQUIVALENT OF 1-1/2" OF WATER OVER THE ENTIRE AREA PER WEEK.A.F.DO NOT TRENCH, EXCAVATE, FILL OR OTHERWISE DISTURB THE SOIL WITHIN THE CRITICAL ROOT ZONE.A.G.ADJUST PROPOSED IMPROVEMENT LOCATIONS AS REQUIRED TO AVOID DAMAGING TREE ROOTS.B.PROTECT THE CROWN AND TRUNK OF TREES TO BE RETAINED ON SITE:B.A.OPERATE EQUIPMENT IN SUCH A WAY AS TO AVOID CONTACT WITH TREE TRUNKS OR BRANCHES.B.B.PRUNING OF PUBLIC PROPERTY TREES SHALL BE PERFORMED BY A LICENSED ARBORIST.C.ALL TREES DAMAGED OR DESTROYED DURING CONSTRUCTION SHALL BE REPLACED WITH A ONE AND ONE-HALF INCH (1 ½ ")TO THREE INCH (3") CALIPER TREE, RATED AS A #1 QUALITY TREE AND AS VERIFIED BY THE CITY FORESTER. SELECTION OFWHAT SPECIES TO REPLACE WILL COME FROM THE TREE SELECTION GUIDE. IF THERE IS NOT ENOUGH ROOM ON THE SUBJECTSITE TO REPLACE THE CALIPER INCH OF TREES THAT WERE REMOVED, THE DEVELOPER WILL CONTRIBUTE A DOLLAR AMOUNTEQUAL TO THE CORRESPONDING CALIPER INCH OF TREES TO A TREE BANK FOR FUTURE TREE PLANTING. THE CITY MAYCHOOSE WHICH PARK, CEMETERY, OR SITE MOST IN NEED OF TREES.Tree Protection Notes:STREET BUFFERS - CALDWELL CITY CODE SECTION 10-07-0820-FT MIN. BUFFER WIDTH WITH 1 TREE PER 35 L.F. AND 1 SHRUB PER 7 L.F.HIGHWAY 20/26:BUFFER L.F.TREES REQUIRED / PROVIDEDSHRUBS REQUIRED / PROVIDED1,056 L.F. 30 / 32151 / 226SMEED PARKWAY:BUFFER L.F.TREES REQUIRED / PROVIDEDSHRUBS REQUIRED / PROVIDED440 L.F.13 / 13 (3 EXISTING) 74 / 79LAND USE BUFFERS - CALDWELL CITY CODE SECTION 10-07-10MIX OF DECIDUOUS AND EVERGREEN TREES WITH TURF AND SHRUBS.TREES SPACED AT 30' INTERVALS AND SHRUBS SPACED AT 2' & 8' INTERVALS.SOUTH BOUNDARY:BUFFER L.F.TREES PROVIDEDSHRUBS PROVIDED798 L.F. 186TREE MITIGATION NOTEALL TREES INTERNAL TO THE SITE THAT ARE PROPOSED TO BE REMOVED ARE DEAD OR NOT OF HEALTHY CONDITION. NOMITIGATION NECESSARY. ONE WILLOW TREE AND TWO CONIFEROUS TREES ALONG SMEED PARKWAY ARE TO BE REMOVED.MITIGATION METHODS WILL BE TO PROPOSE THREE TREES ALONG THE SOUTH SITE BOUNDARY, PER CITY OF CALDWELLSTANDARDS. SEE DEMOLITION PLAN FOR LOCATIONS OF TREES TO BE REMOVED.Project CalculationsTURF SOD,80:20 KENTUCKYBLUEGRASS: RYE GRASSMEDIUM BARK MULCH,3" DEPTH MINIMUM.SITE PROPERTY LINEPLANTING BED CUT EDGE. SEE DETAIL 4/L1.2.VISION TRIANGLENOTE: DO NOT PLANT ANY TREE SPECIES BUT WIRELESS JAPANESE ZELKOVA DIRECTLY UNDER OVERHEADPOWER LINES. THIS TREE AND PROPOSED LOCATIONS WERE CHOSEN BASED ON HEIGHT RESTRICTIONS.A.CONTRACTOR SHALL REPORT TO LANDSCAPE ARCHITECT ALL CONDITIONS WHICH IMPAIR AND/OR PREVENT THE PROPEREXECUTION OF THIS WORK, PRIOR TO BEGINNING WORK.B.ALL LANDSCAPE AREAS SHALL BE WEED FREE AT THE TIME OF LANDSCAPE INSTALLATION. REMOVE ALL ROOTS, WEEDS,ROCKS AND FOREIGN MATERIAL ON THE SURFACE.C.FINISH GRADES TO BE SMOOTH AND EVEN GRADIENTS WITH POSITIVE DRAINAGE IN ACCORDANCE WITH SITE GRADING PLAN.REMOVE RIDGES AND FILL DEPRESSIONS AS REQUIRED TO MEET FINISH GRADES. FINISH GRADE RELATED TO ADJACENT SITEELEMENTS SHALL BE:C.A.1" BELOW TOP OF ADJACENT PAVEMENT, VALVE BOX, VAULT, ETC.C.B.3" BELOW TOP OF CURB UNLESS NOTED OTHERWISE.D.ALL PLANTING BEDS SHALL BE COVERED WITH A MINIMUM OF 3" OF MEDIUM BARK MULCH. SUBMIT SAMPLE FOR APPROVAL.E.ALL PLANTING BEDS SHALL HAVE A MINIMUM OF 18" OF TOPSOIL, SOD AREAS A MINIMUM OF 12" OF TOPSOIL. SPREAD,COMPACT AND FINE GRADE TOPSOIL TO A SMOOTH AND UNIFORM GRADE.F.RE-USE EXISTING SURFACE TOPSOIL WHERE POSSIBLE. VERIFY SUITABILITY OF SURFACE SOIL TO PRODUCE TOPSOIL MEETINGREQUIREMENTS AND AMEND WHEN NECESSARY. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM; CLEAN AND FREE OFTOXIC MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS OR OTHER FOREIGN MATERIAL AND WITH A PH OF 5.5 TO7.0. IF ON-SITE TOPSOIL DOES NOT MEET THESE MINIMUM STANDARDS, CONTRACTORS ARE RESPONSIBLE TO EITHER: A)PROVIDE APPROVED IMPORTED TOPSOIL, OR B.) IMPROVE ON-SITE TOPSOIL WITH METHODS APPROVED BY LANDSCAPEARCHITECT. SUPPLEMENT WITH IMPORTED TOPSOIL WHEN QUANTITIES ARE INSUFFICIENT. CLEAN TOPSOIL OF ROOTS,PLANTS, SODS, STONES, CLAY LUMPS AND OTHER EXTRANEOUS MATERIALS HARMFUL TO PLANT GROWTH.G.IF IMPORTED TOPSOIL FROM OFF-SITE SOURCES IS REQUIRED PROVIDE NEW TOPSOIL THAT IS FERTILE, FRIABLE, NATURALLOAM SURFACE SOIL REASONABLY FREE OF SUBSOIL, CLAY LUMPS, BRUSH, WEEDS AND OTHER LITTER, AND FREE OF ROOTS,STUMPS, STONES LARGER THAN 2 INCHES IN ANY DIMENSION, AND OTHER EXTRANEOUS MATERIALS HARMFUL TO PLANTGROWTH.H.OBTAIN TOPSOIL FROM LOCAL SOURCES OR FROM AREAS HAVING SIMILAR SOIL CHARACTERISTICS TO THAT FOUND ATPROJECT SITE. OBTAIN TOPSOIL ONLY FROM NATURALLY, WELL-DRAINED SITES WHERE TOPSOIL OCCURS IN A DEPTH OF NOTLESS THAN 4".I.NEW TREE PLANTING, SEE DETAILS 1 & 2/L1.2. CONTRACTOR SHALL STAKE ALL TREES DEEMED NECESSARY, I.E...FROM BEINGBLOWN OVER, PLANTED WITH LOOSE ROOT BALL, ETC. CONTRACTOR'S OPTION.J.NEW SHRUB PLANTING. SEE DETAIL 3/L1.2.K.ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR TYPE AND SIZE SHOWN. PLANTSWILL BE REJECTED IF NOT IN A SOUND AND HEALTHY CONDITION.L.ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING AT THE DATE OF SUBSTANTIALCOMPLETION. REPLACE ALL PLANT MATERIAL FOUND DEAD OR NOT IN A HEALTHY CONDITION IMMEDIATELY WITH THE SAMESIZE AND SPECIES AT NO COST TO THE OWNER.M.IN ALL PLANTER BED AND LAWN AREAS, THE TOP 6 INCHES OF TOPSOIL WILL BE AMENDED AT A RATIO OF 3 CUBIC YARDS OFCOMPOST/ORGANIC MATTER PER 1000 SQUARE FEET. ROTO-TILL ORGANIC MATTER A MINIMUM OF 6" INTO TOPSOIL. ALL TREEPITS SHALL BE A MIX OF SEVEN PARTS TOPSOIL (AS SPECIFIED IN THESE NOTES) AND THREE PARTS COMPOST/ORGANICMATTER, BY VOLUME.N.FERTILIZE ALL TREES AND SHRUBS WITH 'AGRIFORM' PLANTING TABLETS OR APPROVED EQUAL. QUANTITY PERMANUFACTURER'S RECOMMENDATIONS.O.TREE PIT BACKFILL PLANTING MIX: BLEND TOPSOIL AND SOIL AMENDMENTS AND FERTILIZER FOR TREE PIT BACKFILL AT THEFOLLOWING RATES. BLEND AMENDMENTS THOROUGHLY WITH SOIL BACKFILL. TREE PITS SHALL BE 5'x5'x1.5' (37.5 CF/ 1.5 CY).O.A.APPLICATION RATES:O.A.A.HUMIC ACID: 25 LBS PER TREE PITO.A.B.COMMERCIAL GRADE COMPOST - 10 CUBIC FEET PER TREE PITO.A.C.PLANTING TABLET FERTILIZER - 4 TABLETS PER TREE PITO.A.D.CALCIFIED DIATOMACEOUS EARTH - 75 LBS PER TREE PITP.SHRUB PIT BACKFILL PLANTING MIX: BLEND TOPSOIL AND SOIL AMENDMENTS AND FERTILIZER FOR SHRUB PIT BACKFILL AT THEFOLLOWING RATES. BLEND AMENDMENTS WITH THOROUGHLY WITH SOIL BACKFILL. SHRUB PITS SHALL BE 2.5'x2.5'x1' (6.25 CF/0.25 CY).P.A.APPLICATION RATES:P.A.A.HUMIC ACID: 2 LBS PER SHRUB PITP.A.B.COMMERCIAL GRADE COMPOST - 2 CUBIC FEET PER SHRUB PITP.A.C.PLANTING TABLET FERTILIZER - 2 TABLETS PER SHRUB PITP.A.D.CALCIFIED DIATOMACEOUS EARTH - 15 LBS PER SHRUB PITQ.IMMEDIATELY CLEAN UP ANY TOPSOIL OR OTHER DEBRIS ON THE SITE CREATED FROM LANDSCAPE OPERATIONS AND DISPOSEOF PROPERLY OFF SITE.R.IN THE EVENT OF A DISCREPANCY NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY.#2-IN CRUSHED BASALTROCK MULCH, 4" DEPTHMINIMUM.R/W R/W101222420.55H20TT T TTTTOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHTOHTOHTOHTOHTOHTOHTOHTOHTOHTOHTR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WRESERVEDSANEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPSANCOCOEPEPEPEPEP EPEPEPEPEPEPEPEPEPEPEPEPSTOPR/WR/WR/W
R/WR/WR/WR/WR/WSTOPR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WHH (10)SG (2)JB (5)VD (5)BG (8)SG (6)HH (6)JB (10)VD (2)SG (6)VD (2)SG (6)SG (6)VD (2)(1) GSAO (1)(8) SG(3) AO(27) HH(4) VD(6) JB(3) TC(6) JF(3) HH(12) HH(3) AO(6) VD(3) BG(6) JB(3) TC(6) JF(3) HH(3) AO(6) VD(12) HH(1) SG(1) JB(2) VD(2) SG(1) ZS(1) GS(2) JF(12) HH(3) JF(5) JB(1) GS(12) HH(12) HH(1) GS(2) VD(2) SG222111SMEED PARKWAY (PUBLIC)US HWY 20 / 26 (CHINDEN BLVD.) (PUBLIC)AO (1)AO (1)BG (6)AO (2)JF (3)AO (1)JF (3)BG (3)BG (3)JF (3)AO (1)AO (1)AO (1)AO (1)(5) SG(3) SG(5) SG(3) SG(6) BGL1.0 - AREA A L1.0 - AREA AHorizontal Scale: 030'60'1" = 30'Landscape Plan-Area BFile Location:g:\2024\124082\cad\_cds\124082 cd l1.0 landscape plan.dwgLast Plotted By:tyler chambersDate Plotted:Sunday, June 22 2025 at 10:36 AM
L1.1Landscape PlanArea BRevisions1.CHANGE BULLETIN #1 - 11/26/24Date of Issuance:Project No.:Project Milestone:----1CONSTRUCTIONNOT FORPERMIT SUBMITTAL09-25-2024124082.00CALDWELL, IDAHO
4106 HWY 20/26
Caldwell, Idaho
Home Depot - Store #____2.CHANGE BULLETIN #2 - 2/28/253.CHANGE BULLETIN #3 - 5/5/254. CITY COMMENTS - 6/23/25CC44CC44CC44CC44CC44CC44