HomeMy WebLinkAboutCFD_Memo_DiamanteEventCenter_2025-02-05 403 Blaine Street • Caldwell, ID 83605 • Phone 208-649-1266 • Fax 208-455-3014 Date 2/5/2025 Caldwell City – Planning and Zoning Re: Case Number: SUP24-000019 Diamante Event Center Dear Planning & Zoning The Caldwell City Fire Department District has reviewed and can approve the application subject to compliance with all the following code requirements and conditions of approval. Any deviation from this plan is subject to Fire Department approval. Please note that unless stated otherwise, this memo represents the requirements of the 2018 International Fire Code (IFC) as adopted by the Idaho State Fire Marshal’s Office. Conditions: 1. Fire hydrants, capable of producing the required fire flow, shall be located along approved fire lanes. Fire hydrant spacing shall meet the requirements of IFC table C105.1.1 (IFC 507.3, IFC B105.2, IFC C105). 2. Fire apparatus access roads shall extend to within 150 feet of all portions of the exterior walls of the first story of a building measured by an approved route around the exterior of the building or facility. (IFC 503.1.1) 3. The minimum outside turning radius of a fire apparatus access road shall be 48 feet. The minimum inside turning radius shall be 28 feet. (IFC 503.2.4) 4. Fire apparatus access roads shall have an approved driving surface of asphalt, concrete or other approved driving surface and can support the imposed load of fire apparatus weighing at least 80,000 pounds. Please provide documentation the road surface meets this standard. (IFC D102.1) 5. Access gates shall comply with requirements of the IFC. If gates are electronically operated, they shall be equipped with an automatic opening mechanism activated by the Opticom or eKnox System. 403 Blaine Street • Caldwell, ID 83605 • Phone 208-649-1266 • Fax 208-455-3014 6. An eKnox lock box, shall be installed on the outside of the building by the main entrance and by the sprinkler room. Additional eKnox Key boxes may be required based on occupancy and proximity of other Boxes. Each eKnox Box shall have labeled master keys to every lock within the structure. The final number and location shall be with the approval of the Caldwell Fire Marshal or designee. 506.1 General Requirement: Fire Department required fire hydrants, access, and street identification shall be installed prior to construction or storage of combustible materials on site. Provisions may be made for temporary access and identification measures. Specific building construction requirements of the International Building Code, International Fire Code and City of Caldwell Code will apply. However, these provisions are best addressed by a licensed Architect at time of building permit application. Regards, Alan Perry Deputy Chief Fire Marshal Caldwell Rural Fire Protection District Aperry@cityofcaldwell.org