Loading...
HomeMy WebLinkAboutAD25-000001_Verizon_Approval Letter April 18, 2025 Attn: Heather Petra (TAEC), on Behalf of Verizon Wireless Heather.petro@taec.net RE: Administrative Determination AD25-000001 – 5207 S. Montana Ave. Dear Ms. Petro, We have received your request for an admin determination to remove a small scale wireless antenna and two radios on the rooftop of Vallivue High School and to replace with a new radio, two antenna mounts and four new antennas as described in the attached elevations. Caldwell City Code encourages colocation of antenna to minimize the number of wireless facilities needed throughout the community and the replacement of a single antenna with four new antenna is permitted. Staff has reviewed the provided elevations and determined that the visual difference between the existing and proposed elevations are minor in nature and do not warrant any further planning review at this time. The project may still be subject to building permit requirements and the applicant shall check with the Building Division to determine if a building permit is warranted. Therefore, this administrative determination is approved contingent on compliance with all necessary permits and adherence to the attached elevations. Please let me know if you have any questions. Sincerely, Morgan Bessaw, AICP Deputy Director of Community Development City of Caldwell Planning and Zoning VERIZON WIRELESS12877 McMILLIAN RDBOISE, IDAHO 83713SITE INFORMATIONDRIVING DIRECTIONSVICINITY MAPSHEETDESCRIPTIONSHEET INDEXT-1TITLESHEETTITLE SHEETA-1EQUIPMENT PLANNOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES SHEET TITLESHEET NUMBERNOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES REVDESCRIPTIONDATEBYREVDESCRIPTIONDATEBYAISSUED FOR 90% CD REVIEW01/10/2025RG1407 E. HOMEDALE RDCALDWELL, ID 83607ID4 VALLIVUE SC-4SMALL CELLIT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEYARE ACTING UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT.T-112877 McMILLIAN RDBOISE, IDAHO 83713MOUNTAIN REGION OFFICE136 S MAIN STREETSUITE 400SALT LAKE CITY, UT 84101BISSUED FOR 90% CD REVIEW 01/29/2025CMBID4 VALLIVUE SC-4PROJECT ID: 16919100MDG LOCATION CODE: 50000452901407 E. HOMEDALE RDCALDWELL, ID 836075G L-SUB6-CARRIER ADDANTENNA PLANSELEVATIONSDETAILSCONTACT INFORMATIONNOT TO SCALEA-2A-3A-4SITE PHOTOSA-5OVERALL SITE PLANA-7CONTRACTOR SHALL VERIFY ALL PLANS, AND EXISTING DIMENSIONS, AND CONDITIONS ONTHE JOB SITE, AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANYDISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAMEDO NOT SCALE DRAWINGSDIAGRAMA-6JURISDICTION:CITY OF CALDWELLSITE ADDRESS:1407 E. HOMEDALE RDCALDWELL, ID 83607LATITUDE AND LONGITUDE:LATITUDE: 43.620403/ 43° 37' 13.451"LONGITUDE: -116.681499/ -116° 40' 53.396"PER RFDS DATED 02-01-2024POWER COMPANY:IDAHO POWER, 1-208-388-2323TECHNOLOGY ASSOCIATES EC, INCCONTACT:HEATHER PETROOFFICE:(801) 678-0209EMAIL:heather.petro@taec.net136 S MAIN STREET, SUITE 400SALT LAKE CITY, UT 84101TECHNOLOGY ASSOCIATES EC, INCCONTACT:TREVOR CLINEOFFICE:(208) 631-0017EMAIL:trevor.cline@taec.net136 S MAIN STREET, SUITE 400SALT LAKE CITY, UT 84101CONTACT:PETER LUNDQUISTOFFICE:(206) 713-9915EMAIL:pete.lundquist@taec.netTECHNOLOGY ASSOCIATES EC, INC136 S MAIN STREET, SUITE 400SALT LAKE CITY, UT 84101STARTING FROM VERIZON OFFICE-12877 MCMILLIAN RD BOISE, IDAHO 83713:1.GET ON I-84 W/ID-55 S IN MERIDIAN FROM N EAGLE RD2.HEAD NORTH TOWARD W MCMILLAN RD3.TURN LEFT ONTO W MCMILLAN RD4.USE THE LEFT 2 LANES TO TURN LEFT ONTO ID-55 S/N EAGLE RD5.PASS BY PANERA BREAD (ON THE RIGHT IN 0.9 MI)6.TURN RIGHT TO MERGE ONTO I-84 W/ID-55 S TOWARD NAMPA7.FOLLOW I-84 W TO ID-55/W KARCHER RD IN CANYON COUNTY. TAKE EXIT 33 FROM I-84 W8.MERGE ONTO I-84 W/ID-55 S, CONTINUE TO FOLLOW I-84 W9.USE THE RIGHT 2 LANES TO TAKE EXIT 33 FOR ID-55 TOWARD NAMPA/MARSING10.CONTINUE ON ID-55/W KARCHER RD TO YOUR DESTINATION IN CALDWELL11.USE THE RIGHT 2 LANES TO TURN RIGHT ONTO ID-55/W KARCHER RD12.PASS BY RED ROBIN GOURMET BURGERS AND BREWS (ON THE LEFT IN 0.7 MI)13.TURN RIGHT ONTO S INDIANA AVE14.AT THE TRAFFIC CIRCLE, TAKE THE 3RD EXIT ONTO E HOMEDALE RD15.TURN RIGHT ONTO S MONTANA AVE16.TURN RIGHT17.TURN RIGHT, DESTINATION WILL BE ON THE LEFTUNDERGROUND SERVICE ALERT,CALL 'DIG ALERT' OF IDAHO@ 811 OR 1-800-342-1585VERIZON WIRELESS12877 W. McMILLAN RDBOISE, ID 83713CONTACT:OFFICE:EMAIL:BOB PRINDLE(208)830-9061Robert.prindle@verizonwireless.comVERIZON WIRELESSCONTACT:CELL:EMAIL:KELLY GIBSON -kelly.gibson@verizonwireless.com9656 PROSPERITY ROADWEST JORDAN, UT 84081PROJECT DESCRIPTIONREFERENCE DOCUMENTSDATEDESCRIPTIONRFDSEXISTING DRAWINGSMAPPINGSTRUCTURAL MAPPING BY GEOSTRUCTURAL01/26/201709/09/2024STRUCTURALDOCUMENTSPASSING MOUNT ANALYSIS BY GEOSTRUCTURAL10/22/2024HANDICAP REQUIREMENTS:FACILITY IS UNMANNED AND NOT FORHUMAN HABITATION, HANDICAP ACCESSREQUIREMENT(S) DO NOT APPLYARCHITECTURE & ENGINEERING:SITE ACQUISITION:PROJECT MANAGER:APPLICANT:RF ENGINEER:CONSTRUCTION ENGINEER:·USE CONCEALFAB LOW-PIM ANTENNA AND CABLE MOUNTING HARDWARE·REMOVE (1) EXISTING OMNI ANTENNA·REMOVE (2) EXISTING RADIOS·SHIFT EXISTING PIPE MAST VERTICALLY 18"·INSTALL (2) NEW ANTENNA MOUNTS·INSTALL (3) NEW 5G ANTENNAS (1 PER SECTOR)·INSTALL (1) NEW OMNI ANTENNA·INSTALL (1) NEW 4890 RADIOCONSTRUCTION DRAWINGS BY TAECSITEPASSING STRUCTURAL ANALYSIS BY GEOSTRUCTURAL09/16/202408/12/2024 PP OVERALLSITE PLANOVERALL SITE PLANNNOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES SHEET TITLESHEET NUMBERNOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES REVDESCRIPTIONDATEBYREVDESCRIPTIONDATEBYAISSUED FOR 90% CD REVIEW01/10/2025RG1407 E. HOMEDALE RDCALDWELL, ID 83607ID4 VALLIVUE SC-4SMALL CELLIT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEYARE ACTING UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT.A-112877 McMILLIAN RDBOISE, IDAHO 83713MOUNTAIN REGION OFFICE136 S MAIN STREETSUITE 400SALT LAKE CITY, UT 84101BISSUED FOR 90% CD REVIEW 01/29/2025CMB11/2" = 100'-0" (11x17)SCALE:(OR)1" = 100'-0" (24x36)100'50'0100'EXISTING ZW ANTENNA& EQUIPMENT AREAFOR EQUIPMENT PLANSEE:1A-2DISCLAIMERTHESE DRAWINGS WERE PRODUCED WITHOUT THE BENEFIT OFA CURRENT LAND SURVEY. ALL PROPERTY LINES, EASEMENTS,AND SETBACKS SHALL BE VERIFIED PRIOR TO START OFCONSTRUCTION. TAEC DOES NOT GUARANTEE THE ACCURACYOF SAID PROPERTY LINES, EASEMENTS, ROADS AND SETBACKS.1A-42A-4HOMEDALE RDMONTANA AVEPROPERTY LINESPROPERTY LINES PROPERTY LINES EXISTINGGRASS FIELDEXISTINGFOOTBALLFIELDEXISTINGBUILDINGEXISTINGROOFHATCHACCESSEXISTING ACCESSTO SITEEXISTING ACCESSTO SITEEXISTINGROOFLADDEREXISTING VZW 12'-0" WIDEACCESS & UTILITY EASEMENT EQUIPMENTPLANEXISTING EQUIPMENTNOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES SHEET TITLESHEET NUMBERNOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES REVDESCRIPTIONDATEBYREVDESCRIPTIONDATEBYAISSUED FOR 90% CD REVIEW01/10/2025RG1407 E. HOMEDALE RDCALDWELL, ID 83607ID4 VALLIVUE SC-4SMALL CELLIT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEYARE ACTING UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT.A-212877 McMILLIAN RDBOISE, IDAHO 83713MOUNTAIN REGION OFFICE136 S MAIN STREETSUITE 400SALT LAKE CITY, UT 84101BISSUED FOR 90% CD REVIEW 01/29/2025CMBEXISTING EQUIPMENT PLAN3/8" = 1'-0" (24x36)(OR)SCALE:3/16" = 1'-0" (11x17)3'2'1'01NEQUIPMENT NOTES:PDF LINEAGE·EMERSON·3 - NE050AC48ATEZ - RECTIFIERS·-54.5V @ 50AMPS·EXISTING (1) 6X12 OVP TO REMAIN·EXISTING (1) 6630 BBU TO REMAIN2A-3EXISTING VZW ANTENNA AREAFOR ANTENNA PLAN SEE:EXISTING VZW PDF/OVP/BBU& BATTERY (SEE NOTE 1)EXISTING VZW PDF3 - NE050AC48ATEZ - RECTIFIERSEXISTING (1) 6X12 OVP TO REMAINEXISTING (1) 6630 BBU TO REMAINEXISTING VZW METER2N.T.S.SCALEEXISTINGHIGHESTROOFEXISTING VENTEXISTING VZW PDF/OVP/BBU& BATTERY (SEE NOTE 1)EXISTING VZW METEREXISTINGHIGHESTROOFEXISTINGLOWERROOFEXISTING VENTN3/8" = 1'-0" (24x36)(OR)SCALE:3/16" = 1'-0" (11x17)3'2'1'03NEW EQUIPMENT PLAN3A-3NEW VZW ANTENNA AREA,FOR ANTENNA PLAN SEE:EXISTING VENTEXISTING VENTEXISTINGLOWERROOF 0°45°90°135°180°315°270°225°ANTENNAPLANSEXISTING ANTENNA PLAN31/4" = 1'-0" (11x17)SCALE:(OR)1/2" = 1'-0" (24x36)2'1'6"0NNOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES SHEET TITLESHEET NUMBERNOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES REVDESCRIPTIONDATEBYREVDESCRIPTIONDATEBYAISSUED FOR 90% CD REVIEW01/10/2025RG1407 E. HOMEDALE RDCALDWELL, ID 83607ID4 VALLIVUE SC-4SMALL CELLIT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEYARE ACTING UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT.A-312877 McMILLIAN RDBOISE, IDAHO 83713MOUNTAIN REGION OFFICE136 S MAIN STREETSUITE 400SALT LAKE CITY, UT 84101BISSUED FOR 90% CD REVIEW 01/29/2025CMBPROPOSED ANTENNA/COAX/RRH KEY21" = 1'-0" (24x36)(OR)SCALE:1/2" = 1'-0" (11x17)1'6"3"0NOTES:1. ALL AZIMUTHS ARE TO BE ESTABLISHED CLOCKWISE FROM THE TRUENORTH HEADING.2. CONTRACTOR SHALL VERIFY ANTENNA CENTERLINE, MECHANICALDOWNTILT, ORIENTATION, AND CABLE LENGTHS PRIOR TO INSTALLATION.REFER TO SITE MODIFICATION CHANGE ORDER FOR ADDITIONALINFORMATION.3. USE CONCEALFAB LOW-PIM ANTENNA AND CABLE MOUNTING HARDWARE.4. GC TO CONFIRM IF VZW WANTS TO REPLACE EXISTING 3315 OVP'S WITH (1)6627 OVP, OR INSTALL 3315-ALM-RS548 RETROFIT BOARDS.5. INSTALLERS TO VERIFY LATEST RF DATA SHEET & PLUMBING / WIRINGDIAGRAMS, PRIOR TO INSTALLATION.HYBRIFLEX LENGTHS:1. FROM THE EQUIPMENT ROOM (N) RACK MOUNT OVP TO THE ANTENNACENTERLINE (N) OVP BOX WILL REQUIRE (2) RUN OF 6x12 HYBRIFLEX BEINSTALLED, SEE CHART FOR LENGTHS.2. FROM THE ANTENNA CENTERLINE OVP BOX TO EACH RRH WILL REQUIRE (1)RUN OF 1x1 HYBRIFLEX BE INSTALLED, LENGTH = 15'NEW ANTENNA PLAN0°45°90°135°180°315°270°225°STATUSAZIMUTHSECTORSERVICEANTENNA KEYMFG.QTY.MODELRADCENTERPOSITIONSTATUS-STATUSALPHAHYBRID KEYMFG.DIELECTRICQTY.DIAMETERRUNTYPERRH KEYMODELQTY.TOWER15'BETAGAMMAUHBA B13 RRH 4x30-EXISTINGN/AEXISTING4JUMPERSHARED-HYBRID CABLES1/2"6x1211NOKIAA1±60'NN.T.S.SCALE11JUMPER-1/2"15'811SECTORALPHABETAGAMMAA2RAYCAP OVP1RAYCAPRCMDC-6627-PF-48ANDREWNH360QM-DG-2XRERICSSONAIR 1672JMACX20OMI236-3CxyREMOVEDNEW0°1NEW0°1LTELTE5GEXISTINGEXISTINGEXISTINGEXISTING±52.0'±50.0'A11±55.0'B1ERICSSONNEW120°15GC1ERICSSONNEW240°15G±50.0'UHIC B4 RRH 2x60-4RNOKIA15'4890 RRHJUMPER-1/2"1ERICSSON81NEWNEWEXISTING VZW OMNI ANTENNA(1 TOTAL) TO BE REMOVEDA1NEW VZW ANTENNA(1 PER SECTOR, 3 SECTORS, 3 TOTAL)1A-53A-5NEW VZW ANTENNA MOUNT WITHMOUNTING PIPES (1 TOTAL)4A-5( ) " " SECTOR @ ( ) " " SECTOR @( ) " " SECTOR @EXISTING BUILDINGPARAPETC1A1B1NEW VZW OMNI ANTENNAWITH NEW MOUNT (1 TOTAL)7A-59A-5A2EXISTING BUILDINGPARAPETCENTERLINE @ 55'CENTERLINE @ 52'EXISTING VZW OVPTO REMAINEXISTING VZW RRHs(2 TOTAL) TO BE REMOVEDEXISTING VZW GPSANTENNA TO REMAINNEW VZW 4890 RRH(1 TOTAL)10A-5EXISTING BUILDINGPARAPETEXISTING VZW OVPEXISTING VZW GPSANTENNACENTERLINE @ 50.0'AIR 1672±52.0'AIR 1672±52.0'EXISTING VZW PIPEMAST SHIFTEDVERTICALLY 18"EXISTING PIPE MASTTO BE SHIFTED UPVERTICALLY 18" ELEVATIONSNOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES SHEET TITLESHEET NUMBERNOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES REVDESCRIPTIONDATEBYREVDESCRIPTIONDATEBYAISSUED FOR 90% CD REVIEW01/10/2025RG1407 E. HOMEDALE RDCALDWELL, ID 83607ID4 VALLIVUE SC-4SMALL CELLIT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEYARE ACTING UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT.A-412877 McMILLIAN RDBOISE, IDAHO 83713MOUNTAIN REGION OFFICE136 S MAIN STREETSUITE 400SALT LAKE CITY, UT 84101BISSUED FOR 90% CD REVIEW 01/29/2025CMBNEW SOUTH ELEVATION21/16" = 1'-0" (11x17)SCALE:(OR)1/8" = 1'-0" (24x36)8'4'2'0FINISH GRADEELEV. 0'-0" REFNOTE:1. INSTALLERS TO VERIFY LATEST RF DATA SHEET & PLUMBING / WIRING DIAGRAMS, PRIOR TO INSTALLATION.2. USE CONCEALFAB LOW-PIM ANTENNA ANDCABLE MOUNTING HARDWARE.CENTERLINE OF EXISTING VZW ANTENNAELEV. ±50.0' AGLTOP OF EXISTING VZW ANTENNAELEV. ±51.6' AGLEXISTING SOUTH ELEVATION11/16" = 1'-0" (11x17)SCALE:(OR)1/8" = 1'-0" (24x36)8'4'2'0EXISTING VZW OMNI ANTENNA(1 TOTAL) TO BE REMOVEDEXISTING VZW RRH'S(2 TOTAL) TO BE REMOVEDNEW VZW ANTENNA(1 PER SECTOR, 3 SECTORS, 3 TOTAL)1A-5NEW VZW OMNI ANTENNAWITH NEW MOUNT (1 TOTAL)7A-53A-5NEW VZW ANTENNA MOUNT WITHMOUNTING PIPES (1 TOTAL)9A-5EXISTING BUILDINGEXISTING VZW GPSANTENNA TO REMAIN4A-510A-5EXISTING VZW OVP(1 TOTAL) TO REMAINFINISH GRADEELEV. 0'-0" REFEXISTING BUILDINGNEW VZW 4890 RRH(1 TOTAL)EXISTING VZW GPSANTENNAEXISTING VZW OVP(1 TOTAL)CENTERLINE OF NEW VZW ANTENNAELEV. ±55.0' AGLCENTERLINE OF NEW VZW ANTENNASELEV. ±52.0' AGLTOP OF NEW VZW ANTENNAELEV. ±56.1' AGLEXISTING VZW PIPEMAST SHIFTEDVERTICALLY 18"EXISTING PIPE MASTTO BE SHIFTED UPVERTICALLY 18" NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES SHEET TITLESHEET NUMBERNOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES REVDESCRIPTIONDATEBYREVDESCRIPTIONDATEBYAISSUED FOR 90% CD REVIEW01/10/2025RG1407 E. HOMEDALE RDCALDWELL, ID 83607ID4 VALLIVUE SC-4SMALL CELLIT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEYARE ACTING UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT.A-512877 McMILLIAN RDBOISE, IDAHO 83713MOUNTAIN REGION OFFICE136 S MAIN STREETSUITE 400SALT LAKE CITY, UT 84101BISSUED FOR 90% CD REVIEW 01/29/2025CMBDETAILSN.T.S.SCALE14N.T.S.SCALE3N.T.S.SCALE9N.T.S.SCALEANTENNA MOUNTANTENNA MOUNT7N.T.S.SCALE10N.T.S.SCALERRU SPECIFICATIONSERICSSON 4890HP 48B2 48B66SFRONTSIDEWIDTH: 15.7" HEIGHT: 20.6"DEPTH: 7.2" WEIGHT: 69.5 LBS-8 RF PORTS, 4T8R PER BAND (S FOR TX)-B2: 4X60W, B66: 4X60W-UP TO 480W IN TOTAL RF POWER-L, NR, NB-IoT-2X2.5/4.9/9.8/10.1/24.3 GBPS CPRI/eCPRI- -48 VDC 2-WIRE (SINGLE DC-CONNECTOR)-AISG v3.0 TMA & RET SUPPORTVIA RS-485 OR RF CONNECTORS-TYPE 4.3-10 RF + CONNECTORS-2 EXTERNAL ALARM-CONVECTIONAL COOLING-OPTIONAL FAN FORINCREASED SITE FLEXIBILITY-IP65, -40 TO +55°CTOPWIDTHHEIGHT DEPTHJMA - CX20OMI236-3CxyANTENNA TYPE:OMNIRADOME COLOR:LIGHT GRAY (RAL 7035)LENGTH:24.0"OUTER DIAMETER:14.6"WEIGHT:36 (16.32 kg)RET CONNECTOR:20 x 4.3-10 RF, BOTTOMANTENNA SPECIFICATIONSØ14.6"24.0"ANTENNA MOUNTING ANTENNA, PER PLANMOUNTING BRACKETSUPPLIED W/ ANTENNAMOUNTING BRACKETSUPPLIED W/ ANTENNAANTENNA SPECIFICATIONS NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES SHEET TITLESHEET NUMBERNOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES REVDESCRIPTIONDATEBYREVDESCRIPTIONDATEBYAISSUED FOR 90% CD REVIEW01/10/2025RG1407 E. HOMEDALE RDCALDWELL, ID 83607ID4 VALLIVUE SC-4SMALL CELLIT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEYARE ACTING UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT.A-612877 McMILLIAN RDBOISE, IDAHO 83713MOUNTAIN REGION OFFICE136 S MAIN STREETSUITE 400SALT LAKE CITY, UT 84101BISSUED FOR 90% CD REVIEW 01/29/2025CMBDIAGRAMSN.T.S.SCALE12N.T.S.SCALENOT USEDUPCONVERTER PLUMBING DIAGRAM NOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES SHEET TITLESHEET NUMBERNOTE: THE ORIGINAL SIZE OF THIS PLAN IS 24" X 36". SCALE RATIO IS NOT VALID FOR REDUCED OR ENLARGED SHEET SIZES REVDESCRIPTIONDATEBYREVDESCRIPTIONDATEBYAISSUED FOR 90% CD REVIEW01/10/2025RG1407 E. HOMEDALE RDCALDWELL, ID 83607ID4 VALLIVUE SC-4SMALL CELLIT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEYARE ACTING UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT.A-712877 McMILLIAN RDBOISE, IDAHO 83713MOUNTAIN REGION OFFICE136 S MAIN STREETSUITE 400SALT LAKE CITY, UT 84101BISSUED FOR 90% CD REVIEW 01/29/2025CMBSITEPHOTOSEXISTING EQUIPMENTVIEW OF EXISTING ANTENNA AREAEXISTING CABINETEXISTING CABINET