HomeMy WebLinkAboutLP-002 OVERALL PLANTING PLANTREESCODEQTYBOTANICAL / COMMON NAMECONTSIZEGB20Ginkgo biloba 'Princeton Sentry'B & B2" CalPrinceton Sentry GinkgoCLASS IILTE6Liriodendron tulipifera 'Emerald City' TMB & B2" CalEmerald City Tulip TreeCLASS IIMRR16Malus x 'Royal Raindrops'B & B2" CalRoyal Raindrops CrabappleCLASS IPNA9Pinus nigra 'Compacta'B & B6`-8` Ht.Compact Austrian PineSHRUBSCODEQTYBOTANICAL / COMMON NAMECONTAME35Aronia melanocarpa 'UCONNAM165' TM5 galLow Scape Mound Black ChokeberryBC3Berberis thunbergii 'Concorde'5 galConcorde Japanese BarberryBDP53Buddleia davidii `Purple Haze`5 galPurple Haze Butterfly BushPOT16Physocarpus opulifolius `SMPOTW` TM5 galTiny Wine NinebarkRFF24Rhamnus frangula `Fine Line`5 galFine Line BuchthornRG22Rhus aromatica 'Gro-Low'5 galGro-Low Fragrant SumacRAG4Ribes alpinum `Green Mound`5 galGreen Mound Alpine CurrantRCC49Rosa x `Carefree Celebration`5 galCarefree Celebration Shrub RoseRF16Rosa x 'Noare' TM5 galFlower Carpet Red Groundcover RoseVTA14Viburnum trilobum `Alfredo`5 galAlfredo Cranberrybush ViburnumEVERGREENCODEQTYBOTANICAL / COMMON NAMECONTJB7Juniperus horizontalis 'Blue Chip'5 galBlue Chip Creeping JuniperGRASSCODEQTYBOTANICAL / COMMON NAMECONTPVH37Panicum virgatum `Heavy Metal`1 galBlue Switch GrassG.C.CODEQTYBOTANICAL / COMMON NAMECONTBG44,064 sfBluegrass Lawn SodSODKentucky Bluegrass MixMLCH5,072 sfShredded Bark Mulch3" DepthNo Weed FabricINERT MATERIALSDESCRIPTION 6" Concrete Mowcurb, Layout Per Plan. See Details on Sheet LP-501PLANT SCHEDULECALDWELL LANDSCAPE REQUIRMENTSMINIMUM REQUIREDPROVIDEDSTREET BUFFER REQUIREMENTSLAKE AVENUE = 964 LFTREE (1 TREE/35 LF OF BUFFER AREAS)SHRUB (1 SHRUBS /7 LF OF BUFFER AREAS)CIRRUS DRIVE = 435 LFTREE (1 TREE/35 LF OF BUFFER AREAS)SHRUB (1 SHRUBS /7 LF OF BUFFER AREAS)28 TREES138 SHRUBSWIDTH OF LANDSCAPE BUFFERLAKE AVENUECIRRUS AVENUE30 FT. (1) Required Landscaping And Improvements Within The Street Buffers: A. Mixture of trees, shrubs, lawn, vegetative and nonvegetative ground cover so that the entirebuffer area is covered. A minimum of seventy percent (70%) of the buffer area shall be coveredwith a turf-type grass. For new plantings, grass sod installation is required. Seeding,hydro-seeding, or similar methods shall not be allowed. (Ord. 3156, 7-16-2018) B. Minimum tree density equivalent to one tree per thirty-five (35) linear feet of buffer area. C. Minimum shrub density equivalent to one shrub per seven (7) linear feet of buffer area. (Ord.2661, 1-7-2008)13 TREES62 SHRUBS30 TREES195 SHRUBS14 TREES83 SHRUBS25 FT.10-22-063_LP-101X\\JUB.COM\CENTRAL\CLIENTS\ID\TRILOGY\PROJECTS\10-22-063_PEREGRINE7\CAD\SHEET\10-22-063_LP-101X.DWGPlot Date:6/13/2023 12:17 PM Plotted By: Shawn WilsonDate Created:6/13/2023
LAST UPDATED: 6/13/2023PEREGRINE ESTATES SUBDIVISION NO. 7CALDWELL, IDAHO
OVERALL PLANTING PLAN10-21-077SEWSEWSEW/AJNLP-002DESIGN BY:DRAWN BY:CHECKED BY:BY APR.DATESHEET NUMBER:DESCRIPTION
REUSE OF DRAWINGS
J-U-B SHALL RETAIN ALL COMMON LAW, STATUTORY, COPYRIGHT AND
OTHER RESERVED RIGHTS OF THESE DRAWINGS, AND THE SAME
SHALL NOT BE REUSED WITHOUT J-U-B'S PRIOR WRITTEN CONSENT.
ANY REUSE WITHOUT WRITTEN CONSENT BY J-U-B WILL BE AT CLIENT'S
SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO J-U-B.
NO.
REVISIONJUB PROJ. # :INCH, SCALE ACCORDINGLYAT FULL SIZE, IF NOT ONEONE INCHFILE :J-U-B ENGINEERS, INC.Meridian, ID 83642
Suite 400
J-U-B ENGINEERS, INC.
www.jub.comPhone: 208.376.7330 J-U-B ENGINEERS, INC.DESIGN BY:DRAWN BY:CHECKED BY:BY APR.DATESHEET NUMBER:DESCRIPTION
REUSE OF DRAWINGS
J-U-B SHALL RETAIN ALL COMMON LAW, STATUTORY, COPYRIGHT AND
OTHER RESERVED RIGHTS OF THESE DRAWINGS, AND THE SAME
SHALL NOT BE REUSED WITHOUT J-U-B'S PRIOR WRITTEN CONSENT.
ANY REUSE WITHOUT WRITTEN CONSENT BY J-U-B WILL BE AT CLIENT'S
SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO J-U-B.
NO.
REVISIONJUB PROJ. # :INCH, SCALE ACCORDINGLYAT FULL SIZE, IF NOT ONEONE INCHFILE :J-U-B ENGINEERS, INC.2760 W. Excursion LN.J-U-B ENGINEERS, INC.