Loading...
HomeMy WebLinkAbout119 Marvin_SitePlan_2024-04-11TBD MARVIN ST. - PARCEL # 22626010 033-4N-3W SE HENDRICKSON SUB 2 - LOT 7, BLOCK 2CALDWELL, IDAHOA1J.B.O.HOMES LLCINDEX OF DRAWINGS SYMBOLS A3. WALL BRACING PLAN AND ROOF PLAN A2. FOUNDATION PLAN AND MAIN LEVEL FLOOR PLAN A1. SITE PLAN & GENERAL INFORMATION DECEMBER 2023 J.B.O. HOMES . SHEET NO. SHEET NO. DETAIL NO. PLAN OR DETAIL NO. SHEET NO. ELEVATION LETTER SHEET NO. SECTION NO. . . . ELEVATION REFERENCE OR DETAIL DETAIL REFERENCE ENLARGED PLAN WALL SECTION SITE PLAN SCALE: 1/8"=1"-0" GENERAL CONDITIONS SNW E A5. SECTION, DETAILS AND ELECTRICAL PLANS A4. ELEVATIONS Date: 12/8/23 Drawn By: A.M.L. Checked By: A.M.L. Project No.: File: IT IS THE DESIGNERS SUGGESTION THAT DRAWINGS BE REVIEWED BY A STRUCTURAL ENGINEER PRIOR TO CONSTRUCTION. IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO BE GUIDELINES FOR CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING ANY QUESTIONS AND MEANINGS IN THE WORKING DRAWINGS AND SPECIFICATIONS: AND THE CONTRACTOR SHALL NOTIFY THE DESIGNER IN WRITING OF ANY ERRORS, OMISSIONS, OR UNSUITABLE DETAILING WHICH MAY CAUSE CONSTRUCTION PROBLEMS. THE DESIGNER'S LIABILITY REGARDING ERRORS AND/ OR OMISSIONS WILL BE LIMITED TO THE CORRECTION OF THE ORIGINAL DRAWINGS, CONSULTANTS LIABILITY IS THE SAME. Sheet No. No. Date Revision PRESCRIPTIVE ENERGY CODE COMPLIANCE THE PROPOSED BUILDING HAS BEEN DESIGNED TO MEET OR EXCEED THE REQUIREMENTS OF THE INTERNATIONAL ENERGY CONSERVATION CODE (2018 IECC) TABLE N1102.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT CLIMATE ZONE 5 WINDOW U-FACTOR 0.35 CEILING R-VALUE 49 WOOD WALL R-VALUE 20 (or) 13+5 FLOOR R-VALUE 30 SLAB R-VALUE 10, 2FT MECHANICAL DUCTING 8 FENESTRATION U-FACTOR 0.30 SKYLIGHT U-FACTOR 0.55 CRAWL SPACE WALL R-VALUE 15/19 150'140'140'150' 20' REAR SETBACK 30' FRONT SETBACK10' SIDE SETBACK10' SIDE SETBACK36'-2 12"34'-912"45'-11"44'-10"10'-0" 10'-0" 106'-1 0 "44'-10"101'- 6 1 2"30'-0"MARVIN ST. A2 EXCAVATE TO 24" MIN. VISQUEEN VAPOR BARRIER BELOW JOISTS W/ .006 MIL CRAWL SPACE CONC. PORCH GRANULAR FILL SLOPE MIN. 1% 4" CONC. SLAB ON 4" COMP. AT PERIMETER SLOPE TO DRIVEWAY WHERE SHOWN & 1 X EXP. JOINTS 4" CONC. SLAB ON 4" COMP. GRANULAR FILL GARAGE FLOOR SLOPE MIN. 2" TO O.H. DOOR SCALE 1/4": 1'-0" FOUNDATION PLAN W/ STUDS @ 16" O.C. OVER 1'-4" X 8' CONC. PONY WALLS FOOTING O.C. TO HOUSE #4 BARS @ 24" Date: 12/8/23 Drawn By: A.M.L. Checked By: A.M.L. Project No.: File: No. Date Revision Sheet No. BLOCKOUT CONC. FOUNDATION STEM WALL 8" AT DOOR OPENING, TYP. 2 A5 3 A5 WALLS & FTG's TO ALLOW FOR CRAWL SPACE ACCESS (TYP) PROVIDE BREAKS IN PONY W/ STUDS @ 16" O.C. OVER 1'-4" X 8' CONC. PONY WALLS FOOTING 16" X 6" SCREENED FND. VENTS W/ ADJUSTABLE DAMPERS 9 1/2" TJI/110 @ 24" O.C. (TYPICAL)FLOOR SYSTEM O.C. TO HOUSE #4 BARS @ 24" 1 A5 6" WIDE CONC. STEM WALL ON 16" X 8" CONC. FOOTING BLOCKOUT CONC. FOUNDATION STEM WALL 8" AT DOOR OPENING, TYP. CONC. PATIO GRANULAR FILL SLOPE MIN. 1% 4" CONC. SLAB ON 4" COMP.4 X 8 WD BM6" WIDE CONC. STEM WALL ON 16" X 8" CONC. FOOTING 6" WIDE CONC. STEM WALL ON 16" X 8" CONC. FOOTING 4 A5 16" X 6" SCREENED FND. VENTS W/ ADJUSTABLE DAMPERS MASTER BEDROOM FOYER 2 CAR GARAGE SLOPE 2" TO O.H. GARAGE DOOR 4" CONC. SLAB VAULTED KITCHEN 9' CLG CARPET FLOOR BEDROOM 3 CARPET FLOOR 9' CLG 9' CLG M. BATH TUB/ SHOWER CONCRETE PORCH PANTRY SINK DRYER WASHER UTILITY RM UPPER CAB.MAIN LEVEL SCALE 1/4": 1'-0" W.I.C. CARPET FLOOR 9' CLG SOLID WOOD DOOR NOT LESS THAN 1 3/8" THK GREAT ROOM VAULTED AREA= 2132 S.F. AREA GARAGE= 508 S.F. DINING 9' CLG MECHANICAL 9' CLG FIREPLACER & S BEDROOM 2 CARPET FLOOR 9' CLG VAULTED 06 SLIDING DOOR 62 82 42 62 02 016 08 AREA PORCH/ PATIO= 692 S.F. COVERED PATIO BATH 9' CLG LINEN045SH 0 CRAWL ACCESS BENCH60'-412"36'-11"23'-512"19'-11"2'-11"43'-0"15'-0"10'-5"10'-21 2"10'-111 4"11'-51 4" 41'-8"65'-2"43'-0" 13'-21 2"8'-101 2"20'-11" 8'-101 2" 2'-4"16'-3"2'-4"60'-412"2'-8"23'-512"43'-0" 41'-8"14'-6"65'-2"43'-0" 4'-101 4"2'-212"18'-10"4'-112"12'-1012"2'-312"11'-312"13'-512"5'-0"24'-3"16'-8"11'-3"9'-3"13'-9"6'-1112"7'-214"10'-6"15'-51 2"27'-61 2" 21'-103 8"3'-6"10'-115 8"6'-8" 5'-0"5'-4"4'-8" 10'-4"3'-31 2"2'-4"3'-912"3'-5"2'-0"2'-112"2'-0"2'-11 2"6'-101 2"5'-10"4'-61 2"5'-11 2" 7" 4'-8" 1'-4"3'-2"6'-0"6'-1112"2'-0" 7'-91 2"4'-91 2" 4'-0" 4'-91 2" 3" 4'-61 2" 61 2" 3'-0"2'-0"3'-6"7"9'-6"7"4'-212"7"4'-012"7"9'-312"4'-9"7'-10"2'-7"13'-312"2'-6"9'-0"11'-0"13'-9"8'-61 2"5'-1"6'-61 2" 3'-6"4'-0"4'-0"6'-212"035SH 0 035SH 0 035SH 0 045SH 0 035 SH 0035 SH 0 04 5SH 0 02 1SL 0 VAULTED LINE BEDROOM 4 CARPET FLOOR 9' CLG CONCRETE PROVIDE PROTECTIVE BARRIER PROVIDE PROTECTIVE BARRIER CRAWL ACCESS 62 03 03 03 62 SHELVES 42 42 05 06 R & S R & S R & SR & STUB/ SHOWER 2x4 STUDS AT 16" O.C. W/ 58" GYP. BOARD WALLS & CEILING 1 HR. SEPARATION WALL 20 MIN. DOOR W/ S.C. HINGES AND SMOKE SEALS SET IGNITION SOURCES A MINIMUM 18" ABOVE FINISHED FLOOR ISLAND REF. PROVIDE LANDING AT EXTERIOR DOORS AS REQUIRED WITH FRAMER BEFORE CONSTRUCTION. - ALL ANGLES 45 U.N.O. - CEILING HEIGHT 9'-1 1/8" MAIN LEVEL - SAFETY GLAZING REQ'D FOR ALL - SAFETY GLAZING REQ'D FOR ALL GLASS WITHIN 24" ARC OF DOORS. - CONTRACTOR TO VERIFY WIN. HEIGHTS o - INSTALL SELF-CLOSING FIRE DOOR BETWEEN GARAGE AND - INSTALL 5/8" GYPSUM BOARD ADJACENT TO LIVING SPACES. GLASS WITHIN 18" OF FLOOR OR GREATER THAN 9 SQ. FT. IN AREA. ON ALL GARAGE WALL SURFACES LIVING SPACE. (EXCEPT AS SHOWN). HEADERS TO BE 4X8 FIR BEAM - ALL WINDOW AND DOOR NOTES: R408 - PROVIDE ADEQUATE CRAWL SPACE VENTILATION4 X 8 WD BM4 X 8 WD BM4 X 8 WD BM4 X 8 WD BM4 X 8 WD BM4 X 8 WD BM4 X 8 WD BM045SH 0 19'-3"2'-312"13'-21 2" 3'-6"4'-101 4" 8'-101 2"20'-11"2'-512"9'-21 2" 2'-51 2"16'-0"2'-51 2"7'-0"14'-4"21'-434"05 3"2'-512"5'-0"6"03 42 LIVING RM. CARPET FLOOR 9' CLG14'-6"7'-0"2'-212"8"8"TBD MARVIN ST. - PARCEL # 22626010 033-4N-3W SE HENDRICKSON SUB 2 - LOT 7, BLOCK 2CALDWELL, IDAHOJ.B.O.HOMES LLC A3 Date: 12/8/23 Drawn By: A.M.L. Checked By: A.M.L. Project No.: File: Date Revision Sheet No. TYPICAL ROOF NAILING NOTES: 1. REFER TO ELEVATIONS FOR ADDITIONAL INFO. ROOF FRAMING PLAN SCALE 1/4": 1'-0" ROOF SYSTEM P.E. WOOD TRUSSES @ 24" O.C.6/126/12 RIDGE 2. PROVIDE ATTIC VENTILATION USING GABLE VENTS AND/OR RIDGE VENTS PER LOCAL CODES. 3. PROVIDE SCREENED SOFFIT VENTILATION AT EAVES PER LOCAL CODES.6/12(2) 9 1/2" LVL(2) 11 7/8" LVL BRACED WALL PANEL SCALE 1/4": 1'-0" 1 BRACED PANEL LENGTH TABLE BASED ON WIND SPEED (<115 mph) BRACED 2 WALL LINE BRACED METHOD BRACED WALL LINE SPACING REQUIRED BRACING LENGHT EXPOSURE FACTOR (C) ROOF EAVE TO RIDGE HEIGHT WALL HEIGHT AJUSTED BRACING LENGHT PROVIDED BRACING LENGHT A B 50 FT 50 FT 60 FT 7.5' 7.5' 10.5' 1.2 1.2 1.2 1.0 1.0 1.0 0.95 8.55' 8.55' 11.97' 20.0' 19.5' CS-WSP 60 FT 9.0'1.2 1.0 10.26'15.8' 20.35'PFH CS-WSP 0.95 0.95 0.95 A 60'-0"3'-8" CS-WSP 4'-0"4'-0"CS-WSPCS-WSP CS-WSP 3/8" WOOD STRUCT. PANEL, ONE SIDE, BLOCKED, NAILED @ 6"/12" w/ 8d . CS-WSP 5/8" GYP. BOARD ONE SIDE, SCREWEDGB WALL BRACE NAILING & HOLD DOWN SCHEDULE @ 7" O.C. FIELD & PERIMETER 1PFH METHOD NAILING PATTERN 1/2" ANCHOR BOLTS@ 6'-0" O.C., TYP. MARK HOLD DOWN ANCHOR BOLTS 3/8" WOOD STRUCT. PANEL, ONE SIDE, BLOCKED, NAILED @ 6"/12" w/ 8d . (1) 5/8" ANCHOR BOLT W/ 7" MIN. EMBED. N/A STHD14 N/A IN CENTER OF PLATE 1/2" ANCHOR BOLTS@ 6'-0" O.C., TYP. SIMPSON 3/8" WOOD STRUCT. PANEL, ONE SIDE, BLOCKED, NAILED @ 6"/12" w/ 8d . CS-PF SEE DETAIL N/A (2) 2x10 HDR(2) 2x8 HDR (2) 2x8 HDR (2) 2x8 HDRVAULTED (2) 2x8 HDR(2) 2x8 HDR(2) 2x8 HDR (2) 2x8 HDR (2) 2x8 HDR(2) 2x8 HDR(2) 2x8 HDR(2) 2x8 HDR6/12 6/12 RIDGERIDGE4'-0" CS-WSP 4'-0" CS-WSP 4'-0"4'-0"CS-WSP4'-0"CS-WSP4'-0"CS-WSP4'-0"CS-WSP3'-6"CS-WSP4'-0"CS-WSP4'-0"CS-WSP4'-0"CS-WSPCS-WSP 3'-41 4" CS-WSP 3'-41 4" 2'-51 2" PFH = 4'-0" 1 1 2'-51 2" PFH = 4'-0" 1 1 1 2 43'-0" B CS-WSP (2) 2x8 HDR(2) 11 7/8" LVL(2) 11 7/8" LVLRIDGE6/126/126/12 6/12 6/12 GIRDER TRUSS CS-WSP 2'-9" CS-WSP 2'-9"4'-0"MAX. 10' HEIGHTFasten wood structural panel (WSP) to header with 8d common or galvanized box nails in 3" grid pattern as shown Header to jack-stud strap per Table R602.10.6.4 on both sides of opening, placed on interior side of wall Min. double 2X4 framing covered with min. 38" thick WSP with 8d common or galvanized box nails at 3" o.c. in all framing (studs, blocking, and sills). Typical Min. lenght of panel per Table R602.10.5 Min. (2) 3500-lb, strap-type hold-down anchors (embedded into concrete and nailed into framing) Min. (1) 58" diameter anchor bolt installed per Section R403.1.6 with 2"x2"x316" plate washer METHOD PFH (Portal Frame With Hold-Downs) Extent of header with double portal frame (two braced wall panels) Extent of header with single portal frame (one braced wall panel)HEIGHTPONY WALLMAX. 12' TOTAL WALL HEIGHT2'-0" to 18'-0" finished width of opening for single or double portal Min. 3" x 11 14" header (if padded out for thickness, place spacer material on the interior side of header). Steel headers are prohibited. Min. footing size under opening is 12"x12". A turned-down slab shall be permitted at door openings. Min. 1000-lb hold-down device (embedded into concrete and nailed into framing) Min. double 2X4 post (king and jack stud). Number of jack studs per Tables R602.7(1) and (2). A A Min. 38" thick wood structural panel (WSP) SECTION A Tension strap per Table R602.10.6.4 (placed on interior side of wall) Fasten top plate to header with two rows of 16d sinker nails at 3" o.c. typ. Fasten king stud to header with (6) 16d sinkers. If needed, panel splice edges shall occur over and be nailed to common blocking within 24" of the portal leg mid-height. One row of 3" o.c. nailing is required in each panel edge. MIn. (2) strap-type hold-down anchors TBD MARVIN ST. - PARCEL # 22626010 033-4N-3W SE HENDRICKSON SUB 2 - LOT 7, BLOCK 2CALDWELL, IDAHOJ.B.O.HOMES LLC A4 Date: 12/8/23 Drawn By: A.M.L. Checked By: A.M.L. Project No.: File: Date Revision Sheet No. SCALE 1/4": 1'-0" FRONT ELEVATION F. FLOOR LTOP P MAIN LEVEL SCALE 1/4": 1'-0" REAR ELEVATION SCALE 1/4": 1'-0" RIGHT ELEVATION SCALE 1/4": 1'-0" LEFT ELEVATION F. FLOOR LTOP P MAIN LEVEL ARCH. SHINGLES 6/12 ROOF PITCH LAP SIDING AS SPEC.MANUF. STONE AS SPEC. SCALE: 1/2" = 1'-0" WALL DETAIL COMP. FILL JOISTS, SEE PLAN GRADE TOP FTG BOTTOM FTG F. FLOOR TOP FND 1/2"DIA. X 10" ANCHOR BOLTS @ 72" O.C. 6 MIL VISQUEEN VAPOR BARRIER 2X6'S @ 16" O.C. STUD WALL 2X6 RDWD SILL P W/L 1/2" GYP. BRD. R-19 INSULATION MIN. R-38 LOOSE FILL INSULATION FASCIA AS SPEC STUCCO AS SPEC. TOP PL 1/2" MASONITE SOFFIT W/ 16" x 6" SCR'D SOFFIT VENTS @ 72" O.C. 1/2" GYP. BRD. P.E. ROOF TRUSSES @ 24" O.C. ROOF & SHTG AS SPEC. SEE ELEVATIONS FOR ROOF PITCH MIN.F. FLOOR LTOP P MAIN LEVEL F. FLOOR LTOP P MAIN LEVEL 6/12 ROOF PITCH 6/12 ROOF PITCH LAP SIDING AS SPEC. ARCH. SHINGLES MANUF. STONE AS SPEC. LAP SIDING AS SPEC. BOARD AND BATTEN SIDING AS SPEC BOARD AND BATTEN SIDING AS SPEC BOARD AND BATTEN SIDING AS SPEC ARCH. SHINGLESARCH. SHINGLES R306 - PROVIDE ADEQUATE ATTIC SPACE VENTILATION INSTALL STONE AS PER MANUFACTURER'S SPECIFICATIONS MANUF. STONE AS SPEC. MANUF. STONE AS SPEC. LAP SIDING AS SPEC.TBD MARVIN ST. - PARCEL # 22626010 033-4N-3W SE HENDRICKSON SUB 2 - LOT 7, BLOCK 2CALDWELL, IDAHOJ.B.O.HOMES LLC A5 Date: 12/8/23 Drawn By: A.M.L. Checked By: A.M.L. Project No.: File: No. Date Revision Sheet No. MAIN LEVEL ELECTRICAL PLAN SCALE 1/4": 1'-0" 1. MECHANICAL CONTRACTOR SHALL VERIFY ALL SIZES AND LOCATIONS OF AL VENTS AND DUCTS PRIOR TO CONSTRUCTION. 2. SMOKE DETECTORS SHALL RECEIVE THEIR PRIMARY POWER FROM BUILDING WIRING AND SHALL BE EQUIPPED WITH BATTERY BACKUP. WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER THAN REQUIRED FOR OVERCURRENT PROTECTION. ALL SMOKE DETECTORS ARE TO BE WIRED TOGETHER ON ONE CIRCUIT AND DESIGNED FOR ALL DETECTORS TO SOUND IF ONE DETECTOR IS ACTIVATED. 3. IN BATHROOMS, WATER CLOSET COMPARTMENTS AND LAUNDRY ROOMS, PROVIDE A MECHANICAL FAN CAPABLE OF PROVIDING FIVE AIR CHANGES PER HOUR OR OPERABLE WINDOW. THE POINT OF DISCHARGE OF EXHAUST AIR SHALL BE AT LEAST 3 FEET FROM ANY OPENING INTO THE BUILDING. 4. FURNACE DUCTS FROM THE GARAGE INTO THE DWELLING ARE TO BE A MINIMUM OF 26 GAUGE GALVANIZED SHEET METAL WITH NO OPENINGS INTO GARAGE. FIRESTOP AND SEAL AROUND DUCT PENETRATIONS. 5. APPLIANCES GENERATING A SPARK, GLOW OR FLAME, INSTALLED IN GARAGES, MUST KEEP PILOTS, BURNERS, HEATING ELEMENTS, AND SWITCHES A MINUMUM OF 18 INCHES ABOVE THE FLOOR. 6. FURNACES, HEAT PUMPS, WATER HEATERS, AND OTHER MECHANICAL EQUIPMENT AS WELL AS GAS PIPING LOCATED IN RESIDENTIAL GARAGES ARE TO BE PROTECTED FROM AUTOMOBILE IMPACT. SEE MECHANICAL INSPECTOR FOR PROTECTION REQUIREMENTS. 7. ALL FIXTURES, SWITCHES, OUTLETS AND FANS ARE SHOWN AS REQUIRED BY CODE. PLACEMENT OF EACH MAY VARY AT TIME OF CONSTRUCTION AS PER ELECTRICAL CONTRACTOR. 50% OF LIGHTING NEEDS TO BE COMPACT FLUORESCENT BULBS. 8. SEE FLOOR PLAN SHEET FOR FINAL ARCHITECTURAL FEATURES AND REVISIONS - THIS PLAN IS FOR MECHANICAL AND ELECTRICAL LAYOUT ONLY. CHANDELIER LIGHT FIXTURE SMOKE DETECTOR RECESSED CAN LIGHT FIXTURE WALL MOUNTED LIGHTS 4x10 FLOOR VENT 2 1/2"x12" TOE KICK REGISTER F FLUORESCENT FIXTURE (SIZE AS INDICATED) SWITCHED DUPLEX OUTLET ( TOP HALF ONLY) 220 VOLT OUTLET THREE-WAY SWITCH SWITCH 220 SS3G.F.I. OUTLET LIGHT FAN WATER PROOF OUTLET GIFR WP S ELEC./MECH. SYMBOL SCHEDULE DUPLEX OUTLET TK LIGHT FAN GENERAL ELECTRICAL CARBON MONOXIDE DETECTORCO PENDANT LIGHTS TK TK S SCO W.P. W.P. F FOUNDATION DETAIL SCALE: 1"-1'-0"1 0'-0" CONT FOOTING, SEE FOUNDATION PLAN FOR SIZE & REINF. CONT. EDGE NAILING SHEAR WALL SEE PLAN 2x6 STUDS @ 16" O.C., FOR ADDITIONAL STUDS OR POST SEE FOUNDATION PLAN 6" CONCRETE STEM WALL FLOOR DECK 3 4" T&G W/ 10d @ 6" O.C. ALL EDGES & 12" O.C. FIELD 'ITS' HANGER I-JST, SEE PLAN CRAWL SPACE2'-0"MIN2x6 PT SILL PLATE W/ 12 DIA. x 6" SCREW ANCHOR @ 32" W/ 1" DP. COUNTR SUNK FOUNDATION DETAIL (I-JST PARALLEL) SCALE: 1"-1'-0"2 0'-0" CONT FOOTING, SEE FOUNDATION PLAN FOR SIZE & REINF. CONT. EDGE NAILING SHEAR WALL SEE PLAN 6" CONCRETE STEM WALL FLOOR DECK 34" T&G W/ 10d @ 6" O.C. ALL EDGES & 12" O.C. FIELD I-JST, SEE PLAN CRAWL SPACE2'-0"MIN2x6 PT SILL PLATE W/ 12 DIA. x 6" SCREW ANCHOR @ 32" W/ 1" DP. COUNTERSUNK GARAGE WALL FOUNDATION SCALE: 1"-1'-0"3 FOOTING, SEE FOUNDATION PLAN MIN.6" CONCRETE STEM WALL 6"1 12"CLR4" CONC. SLAB ON GRADE W/ #3 @ 18" O.C. E.W. I-JST, SEE PLAN 2'-0"CONT. EDGE NAILING SHEAR WALL SEE PLAN FLOOR DECK 34" T&G W/ 10d @ 6" O.C. ALL EDGES & 12" O.C. FIELD 2x6 PT SILL PLATE W/ 12 DIA. x 6" SCREW ANCHOR @ 32" W/ 1" DP. COUNTERSUNK 'ITS' HANGER SCALE: 1"-1'-0"4 INTERIOR FOOTING 2x6 STUD WALL ABOVE WHERE APPLIC. 2x CRIPPLE WALL @ 16" O.C. ALIGN W/ I-JOIST 12" DIA x 6" SCREW ANCHOR @ 32" O.C. FOOTING, (SEE PLAN) P.T. SILL PLATE 10d TN EA. SIDE AT JOIST I JOIST, SEE PLAN FLOOR SHEATHING, SEE NOTES EDGE NAILING 10d @ 6" O.C. I-JOIST BLK'G ONLY UNDER UPPER WALLS TK TK F F S S S S 220 S SCO 220 SSS SS3S3 SS3 S3S S SS SS S S3S3 SSSS 3 S3 S S 3S 3 SS3 S3 SGIFR GIFRGIFR6 MIL VISQUEEN VAPOR BARRIER 1/2" GYP. BRD. ROOF & SHTG AS SPEC. 2X6'S @ 16" O.C. STUD WALL R-19 INSULATION, MIN. SCALE 1/4": 1'-0" SECTION A ARCH. SHINGLES 6/12 ROOF PITCH SIDING AS SPEC. A5 2 @ 24" 0.C. (TYP) KITCHEN R-38 LOOSE FILL INSULATION, MIN. P.E. ROOF TRUSSES @ 24" O.C. VAULTED 912" TJI 110 F. FLOOR LTOP P 9'-118"MAIN LEVEL ALL T.V., PHONE, CAT5 OUTLETS PER BUILDER'S SPEC'S. GIFR FSS STK W.P. S AND MECHANICAL NOTES TBD MARVIN ST. - PARCEL # 22626010 033-4N-3W SE HENDRICKSON SUB 2 - LOT 7, BLOCK 2CALDWELL, IDAHOJ.B.O.HOMES LLC