Loading...
HomeMy WebLinkAboutCFD Subdivision SUP24-000013 DENNETT ADU SMALL LIVING BUILD (1) 403 Blaine Street • Caldwell, ID 83605 • Phone 208-649-1266 • Fax 208-455-3014 Date 9/3/2024 Caldwell City – Planning and Zoning Re: Case Number SUP24-000013 DENNETT ADU SMALL LIVING BUILD Dear, Planning & Zoning The Caldwell City Fire Department District has reviewed and can approve the application subject to compliance with all the following code requirements and conditions of approval. Any deviation from this plan is subject to Fire Department approval. Please note that unless stated otherwise, this memo represents the requirements of the 2018 International Fire Code (IFC) as adopted by the Idaho State Fire Marshal’s Office. Conditions: 1. Fire hydrants, capable of producing the required fire flow, shall be located along approved fire lanes. Fire hydrant spacing shall meet the requirements of IFC table C105.1.1 (IFC 507.3, IFC B105.2, IFC C105). 2. Roadway serving a fire hydrant shall be a minimum of 26-feet in width. (IFC D103.1) 3. Fire apparatus access roads shall extend to within 150 feet of all portions of the exterior walls of the first story of a building measured by an approved route around the exterior of the building or facility. (IFC 503.1.1) 4. Fire apparatus access roads shall have an unobstructed width of not less than 20 feet and an unobstructed vertical clearance of not less than 13 feet 6 inches. (IFC 503.2.1) 5. 05-07-10: PLACEMENT AND POSTING OF ADDRESSES ON BUILDINGS AND SIGNS: (4) All address numbers shall be a minimum of six inches (6") high with a minimum stroke width of 0.5 inch. All sizable complexes or facilities (such as shopping centers, industrial sites, apartment complexes, etc.) shall have address numbers a minimum of twelve inches (12") high. Any building located significantly back from the street it faces may be required to post proportionately larger sized numerals as deemed adequate to identify the structure. All subaddress numbers shall be a minimum of four inches (4") high. (Ord. 2828, 6-21-2010) 403 Blaine Street • Caldwell, ID 83605 • Phone 208-649-1266 • Fax 208-455-3014 General Requirement: Fire Department required fire hydrants, access, and street identification shall be installed prior to construction or storage of combustible materials on site. Provisions may be made for temporary access and identification measures. Specific building construction requirements of the International Building Code, International Fire Code and City of Caldwell Code will apply. However, these provisions are best addressed by a licensed Architect at time of building permit application. Regards, Alan Perry Deputy Chief Fire Marshal Caldwell Rural Fire Protection District Aperry@cityofcaldwell.org