Loading...
HomeMy WebLinkAboutAlfredo Auto Storage_VicinityMap_2024-04-29Project number Date Drawn by Checked by 280 N. 8th Street, Studio 204, Boise, Idaho 83702 erik@erikhagen.com 310.755.5987 Copyright © 2023 Erik Hagen, Architect PLLCVicinity MapArea Map Sheet Index Project Data Building Code Review Project Summary Zoning Code Review 4/2/2024 7:23:09 PMG0.1 Cover Sheet & Code Data 23493718 Cleveland Blvd, Caldwell ID 83605Alfredo & Edgar Escobedo4/2/2024 Author CheckerAlfredo Auto Sales Storage BuildingAlfredo Auto Sales Storage Building 3718 Cleveland Blvd, Caldwell ID 83605 Alfredo & Edgar Escobedo 4/2/2024 Property: 3718 Cleveland Blvd, Caldwell ID 83607 Nicol Farwell Add 1.2 Acres (~52,272 GSF) Legal Description: 35-4N-3W NE Nicol Farwell Add, Loits 3&4, Block 1 Parcel ID: 04389000 0 Owner: Sanchez Alfredo Escobedo, Escobedo Horalia Existing Structures: Retail Store, 3,208 SF, built 1978 Small Shop: 600 SF, built 2021 Detached Residential Garage: 800 SF, built 1978 Paved Area: 25,180 SF, paved 1980 Chainlink Fence: 708 LF, installed 1980 Project Contacts: Client Owners: Edgar Escobedo 208.380.5849 edgarescobedo98@gmail.com Client Contractor: Ivan Castillo 208.283.3311 odysseyidaho@gmail.com Architect: Erik Hagen 208.290.4954 erik@erikhagen.com Civil Engineer: Mike Liimakka 208.322.5250 mike@aoengineering.com Structural Foundation Engineer: Sarah McClendon 208.342.2919 sarah@mcclendonengineering.com MEP Engineers: Bruno Loza 208.376.9820 bruno@eciboise.com Authorities Having Jurisdiction (AHJ): City of Caldwell, Building Department Applicable Building Codes: 2018 International Building Code 2018 International Existing Building 2018 International Fire Code 2017 National Electrical Code 2018 International Mechanical Code 2018 International Fuel Gas Code 2017 Idaho State Plumbing Code (based off of the 2015 Uniform Plumbing Code) 2018 International Energy Conservation Code (With State Amendments) Basic Design Criteria: Seismic Category - B Exposure - B Wind Loading - 115 miles per hour Roof Snow Load - 25 pounds per square foot Basic Ground Snow Load - 20 pounds per square foot Frost Depth - 24 inches Minimum Collateral Load - 5 pounds per square foot Ground Snow Loadf: 20 psf Occupancy Type: S-1 Moderate Hazard (lumber, flooring, cardboard, glues, bags, aerosol) Occupant Load: S-1 Warehouse @ 1/500 SF = 14 occupants. Construction Type (Table 506.2): Type V-B Non-Sprinklered Max. Height & Stories: 40', 1-story Allowable Area: 5,500 SF Allowable Area Increase: 1.5x (yards 30' > 20' on 2 sides) = 8,250 SF Plumbing Fixtures (Table 2902.1) Min. Req'd Plumbing: Storage Occupancies: 1/100 occupants. = 1 unisex restroom, 1 service sink (no exception) 2902.2 Separate Facilities Exception 2 Structures or tenant spaces of 15 Occs or fewer 2902.6 Drinking Fountain not req'd < 15 occs NEW 25' TALL, 7,200 GSF PRE-ENGINEERED METAL BUILDING FOR INSIDE AUTO STORAGE (NO AUTOMOTIVE REPAIRS OR MAINTENANCE TO OCCUR) W/ 54 SF RESTROOM. EXISTING OUTDOOR STORAGE YARD TO REMAIN. Sheet Number Sheet Name Sheet Issue Date G0.1 Cover Sheet & Code Data 4/2/2024 A0.1 Site Plans 4/2/2024 A1.1 Proposed Plans 4/2/2024 A3.1 Proposed Exterior Elevations 4/2/2024I-84C L E V E LA N D B LV D CL E V E LA N D B LV DDEARBORN STS 21ST AVEFRANKLIN RD MIDLAND BLVDZoning: C-3 Service Commercial Uses (10-02-02): Permitted: Commercial-Automotive: Repair Services, Used Auto Sales, Storage Indoor Commercial Retail: Retail & Equipment Sales & Services, Furniture Shop, Hardware Store, Lumber Yard Commercial Service: Food Stand, Mobile Food, Restaurant, Parking Lot Special Use: Commercial Automotive: Tow Yard, Body Shop, Storage Outdoor Commercial Service: Outdoor Storage Uses Not Permitted: Junk Yard Heights, Setbacks, Areas (10-02-03): Lot Area: No Min, No Max. Street Frontage: N/A Height: None Setbacks: None Parking Requirements (10-02-05 Table 4): Restaurants: 1 per 4 seats. Food Truck, no seats = no parking required. Retail Sales (Shopping Mall): 1 per 300 SF of area 1,160 SF Retail Building for Sheds = 4 stalls required. Automotive Repair Shop: 2 per Service Bay 2 bays existing = 4 stalls required Industrial Storage: 1 per 2,000 SF of floor area 7,200 SF proposed = 4 stalls required Automotive Storage Yard: 1 per 10,000 SF (Contractors Yard) or 15,000 SF (Automotive Yard) of lot area 27,500 SF of Storage Yard = 3 stalls required Total Automotive Parking Required: 15 stalls total required. Bicycle Parking (10-02-05(6)A.): 5% of required parking spaces for Automotive = 1 Bike Parking required. 15% of required parking spaces for Retail & Service = 3 Bike Parking required Bike Parking Required: (1) 4-stall bike rack. Fencing (10-02-07.(4)B.): All screen fencing shall be 6' min. in height. Maximum height of fencing is 8' Fencing shall not be placed within the clear vision triangle of an intersection. Fencing shall be setback a distance equal to the Landscape Buffer. Landscaping (10-07-05(3)) No Open Space requirements Vision Triangle (10-07-07) 40' from curb face at intersections 20' from driveway edgess & 10' in Landscape Buffer (10-07-08(3)): 10' along Local Streets (38th St) 25' along Major Arterials (Cleveland Blvd) 70% covered with turf 1 tree per 35 LF 1 shrub per 7 LF Landscaping Notes: 1. Certification must be provided to the city that all of the trees or plants installed are free from disease and are not toxic, poisonous or otherwise a nuisance. 2. Landscaping and/or weed maintenance of all irrigation, drainage and utility easements and/or rights of way are the responsibility of the property owner. 3. All tree planting shall be based on the city's "arboricultural standards and specifications guide" 4. Minimum Plant Sizes: A. Evergreen trees: 6 to 7 foot height minimum B. Ornamental trees: 2 inch caliper minimum C. Shade trees: 2 inch caliper minimum D. Woody shrubs: 2 gallon pot minimum No. Description Date