Loading...
HomeMy WebLinkAboutAlfredo Auto Storage_ProposedPlans_2024-04-29WH 4321 5 6 D C B A 54 SF Restroom 6875 SF Storage Warehouse 1.1 5.9 C.9 A.1 5'-0"4'-4"31'-8"14'-0"5'-0"12'-0"12'-0"12'-0"12'-0"12'-0"12'-0"12'-0"12'-0"12'-0"12'-0"4"8'-0"8'-0"WALL HUNG LAVATORY UTILITY SINK ACCESSIBLE CLEARANCES, TYP. UNCONDITIONED 4" REINFORCED CONCRETE SLAB ON GRADE OVERHEAD DOOR, TYP. PEMB STRUCTURAL COLUMN, TYP. PEMB METAL PANEL ON Z-GIRT 6 A5.1 6 A5.1 7 A5.1 7 A5.1 8 A5.1 4321 5 6 D C B A 1.1 5.9 C.9 A.1 6875 SF Storage Warehouse 54 SF Restroom EQ29'-4"EQ15'-5"29'-6"29'-6"29'-6"15'-5"3'-4"52'-0"3'-4"VERTICAL STRUCTURE HUNG SPACE HEATER UNIT, TYP. PENDANT HUNG INDUSTRIAL LED FIXTURE, TYP. SURFACE MOUNTED LINEAR LED EXHAUST FAN SUPPLY AIR DIFFUSER EXTERIOR WALL PACK AT 10' A.F.F., TYP. PEMB Z-PURLIN, TYP. PEMB BEAM, TYP. 6 A5.1 7 A5.1 8 A5.1 Project number Date Drawn by Checked by 280 N. 8th Street, Studio 204, Boise, Idaho 83702 erik@erikhagen.com 310.755.5987 Copyright © 2023 Erik Hagen, Architect PLLC4/2/2024 7:23:21 PMA1.1 Proposed Plans 23493718 Cleveland Blvd, Caldwell ID 83605Alfredo & Edgar Escobedo4/2/2024 Author CheckerAlfredo Auto Sales Storage Building1/8" = 1'-0"1 Proposed Floor Plan 0'4'8'16'32'PROJECT NORTHTRUE NORTHNo. Description Date GENERAL NOTES: 1. NOTE EVERY ITME IS NOTED OR DIMENSIONED. NOTES & DETAILS ARE TYPICAL & SHOULD BE CONSIDERED DUP[LICATED WHERE NOT NOTED OR DIMENSIONED. 2. CONTRACTOR TO VERIFY AS-BUILT CONDITIONS PRIOR TO CONSTRUCTION. ANY DISCREPANCIES FOUND SHALL BE BROUGH TO THE ARCHITECTS ATTENTION FOR REVIEW AND RESOLUTION PRIOR TO BUILDING. 3. ALL DIMS ARE FACE OF STUD, UNLESS NOTED OTHERWISE. 4. DOOR TAGS REPRESENT DOOR SIZE (3070 = 3'-0" X 7'-0" DOOR). A. ROUGH OPENING SHALL BE 2 1/2" WIDER AND 1 1/2" TALLER THAN DOOR B. DOORS SHALL BE LOCATED 4" FROM ADJACENT WALL WHERE NOT OTHERWISE INDICATED C. ALL DOORS TO HAVE LEVER HANDLES 5. FURNITURE BY OTHERS, SHOWN FOR INFORMATIONAL PURPOSES ONLY 6. ALL WALLS TO BE ANCHORED TO THE FLOOR w/ 1/2" KBTZ OR EQUAL @ 24" O.C. AND BRACED AT THE CEILING W/ CEILING JOISTS, OR ALTERNATING LEG BRACES TO THE DECK ABOVE @ 48" O.C. 7. ALL WALLS 9'-0" TALL, UNLESS NOTED OTHERWISE, W/ DRYWALL TO BE 5/8" TYPE X 8. CEILINGS TO BE MOUNTED DIRECTLY TO THE UNDERSIDE OF JOISTS, UNLESS NOTED OTHERWISE ABBREVIATIONS: CLG: CEILING HDR: HEADER FTG: FOOTING CFCI: CONTRACTOR FURNISHED, CONTRACTOR INSTALLED OFCI: OWNER FURNISHED, CONTRACTOR INSTALLED OFOI: OWNER FURNISHED, OWNER INSTALLED TBD: TO BE DETERMINED TYP: TYPICAL RO: ROUGH OPENING DO: DO OVER / REPEAT *T TEMPERED GLAZING TOF TOP OF FOOTING TOC: TOP OF CONCRETE TOW: TOP OF WALL UNO: UNLESS NOTED OTHERWISE 1/8" = 1'-0"2 Proposed Ceiling Plan 0'4'8'16'32'PROJECT NORTHTRUE NORTH