Loading...
HomeMy WebLinkAboutAlfredo Auto Sales Storage Building SUP Application Revision DrawingsProject numberDateDrawn byChecked by280 N. 8th Street, Studio 204,Boise, Idaho 83702erik@erikhagen.com 310.755.5987Copyright © 2023 Erik Hagen, Architect PLLCVicinity MapArea MapSheet IndexProject DataBuilding Code ReviewProject SummaryZoning Code ReviewProject status6/27/2024 5:24:51 PMG0.1Cover Sheet &Code Data23493718 Cleveland Blvd, Caldwell ID 83605Alfredo & Edgar Escobedo6/27/2024ErikErikAlfredo Auto Sales Storage BuildingAlfredo Auto Sales Storage Building3718 Cleveland Blvd, Caldwell ID 83605Alfredo & Edgar Escobedo6/27/2024Planning RevisionsProperty:3718 Cleveland Blvd, Caldwell ID 83607Nicol Farwell Add1.2 Acres (~52,272 GSF)Legal Description:35-4N-3W NE Nicol Farwell Add, Loits 3&4, Block 1Parcel ID: 04389000 0Owner: Sanchez Alfredo Escobedo, Escobedo HoraliaExisting Structures:Shed Sales Retail: 2,110 sf, built 1978Retail Sales Office: 980 SFShed Shop: 1,130 Parts Storage Shop: 1,100 SF, built 1978Detached Storage Garage: 800 SF, built 1978Small Shop Storage: 600 SF, built 2021Small Shop Storage: 600 SF, built 2022Paved Area: 25,180 SF, paved 1980Chainlink Fence: 708 LF, installed 1980Project Contacts:Client Owners:Edgar Escobedo208.380.5849edgarescobedo98@gmail.comClient Contractor:Ivan Castillo208.283.3311odysseyidaho@gmail.comArchitect:Erik Hagen208.290.4954erik@erikhagen.comCivil Engineer:Mike Liimakka208.322.5250mike@aoengineering.comStructural Foundation Engineer:Sarah McClendon208.342.2919sarah@mcclendonengineering.comMEP Engineers:Bruno Loza208.376.9820bruno@eciboise.com Authorities Having Jurisdiction (AHJ): City of Caldwell, Building DepartmentApplicable Building Codes:2018 International Building Code2018 International Existing Building2018 International Fire Code2017 National Electrical Code2018 International Mechanical Code 2018 International Fuel Gas Code 2017 Idaho State Plumbing Code (based off of the 2015 Uniform Plumbing Code)2018 International Energy Conservation Code (With State Amendments)Basic Design Criteria:Seismic Category - BExposure - BWind Loading - 115 miles per hourRoof Snow Load - 25 pounds per square footBasic Ground Snow Load - 20 pounds per square footFrost Depth - 24 inchesMinimum Collateral Load - 5 pounds per square footGround Snow Loadf: 20 psfOccupancy Type:S-1 Moderate Hazard (lumber, flooring, cardboard, glues, bags, aerosol)Occupant Load:S-1 Warehouse @ 1/500 SF = 14 occupants.Construction Type (Table 506.2): Type V-B Non-SprinkleredMax. Height & Stories: 40', 1-storyAllowable Area: 5,500 SFAllowable Area Increase: 1.5x (yards 30' > 20' on 2 sides) = 8,250 SFPlumbing Fixtures (Table 2902.1) Min. Req'd Plumbing:Storage Occupancies: 1/100 occupants. = 1 unisex restroom, 1 service sink (no exception)2902.2 Separate Facilities Exception 2 Structures or tenant spaces of 15 Occs or fewer2902.6 Drinking Fountain not req'd < 15 occsNEW 25' TALL, 7,200 GSF PRE-ENGINEERED METAL BUILDING FOR INSIDE AUTO STORAGE (NO AUTOMOTIVE REPAIRS OR MAINTENANCE TO OCCUR) W/ 54 SF RESTROOM.EXISTING OUTDOOR STORAGE YARD TO REMAIN.Sheet Number Sheet Name Sheet Issue DateG0.1 Cover Sheet & Code Data 4/2/2024A0.1 Site Plans 4/2/2024A1.1 Proposed Plans 4/2/2024A3.1 Proposed Exterior Elevations 4/2/2024I-84CLEVELAND BLVDCLEVELAND BLVDDEARBORN STS 21ST AVEFRANKLIN RDMIDLAND BLVDZoning: C-3 Service CommercialUses (10-02-02):Permitted:Commercial-Automotive: Repair Services, Used Auto Sales, Storage IndoorCommercial Retail: Retail & Equipment Sales & Services, Furniture Shop, Hardware Store, Lumber YardCommercial Service: Food Stand, Mobile Food, Restaurant, Parking LotSpecial Use:Commercial Automotive: Tow Yard, Body Shop, Storage OutdoorCommercial Service: Outdoor StorageUses Not Permitted: Junk YardHeights, Setbacks, Areas (10-02-03):Lot Area: No Min, No Max.Street Frontage: N/AHeight: NoneSetbacks: NoneParking Requirements (10-02-05 Table 4):Restaurants: 1 per 4 seats.Food Truck (temporary), no seats = no parking required.(E) Retail Sales (Shopping Mall): 1 per 300 SF of area980 SF Retail Building for Sheds = 4 stalls required(E) Misc. (Shop) Storage: 1 per 2,000 SF of floor area5 separate spaces @ (1,130 SF, 1,100 SF, 800 SF, 600 SF & 600 SF) = 4,230 SF = 3-5 stalls required(N) Industrial (Automotive) Storage: 1 per 2,000 SF of floor area7,200 SF proposed =4 stalls requiredAutomotive Storage Yard: 1 per 15,000 SF (Automotive Yard) of lot area27,500 SF of Storage Yard = 2 stalls requiredTotal Automotive Parking Required: 12-14 stalls total required.Bicycle Parking (10-02-05(6)A.):5% of required parking spaces for Automotive = 1 Bike Parking required.15% of required parking spaces for Retail & Service = 3 Bike Parking requiredBike Parking Required: (1) 4-stall bike rack.Fencing (10-02-07.(4)B.):All screen fencing shall be 6' min. in height.Maximum height of fencing is 8'Fencing shall not be placed within the clear vision triangle of an intersection.Fencing shall be setback a distance equal to the Landscape Buffer.Landscaping (10-07-05(3))No Open Space requirementsVision Triangle (10-07-07)40' from curb face at intersections20' from driveway edgess & 10' inLandscape Buffer (10-07-08(3)):10' along Local Streets (38th St)25' along Major Arterials (Cleveland Blvd)70% covered with turf1 tree per 35 LF1 shrub per 7 LFLandscaping Notes:1. Certification must be provided to the city that all of the trees or plants installed are free from disease and are not toxic, poisonous or otherwise a nuisance.2. Landscaping and/or weed maintenance of all irrigation, drainage and utility easements and/or rights of way are the responsibility of the property owner.3. All tree planting shall be based on the city's "arboricultural standards and specifications guide"4. All trees per the Treasure Valley Tree Selection Guide suitable for Zone 5/65. Minimum Plant Sizes:A. Evergreen trees: 6 to 7 foot height minimumB. Ornamental trees: 2 inch caliper minimumC. Shade trees: 2 inch caliper minimumD. Woody shrubs: 2 gallon pot minimumNo. Description Date1 Planning Application 4/2/20242 Planning Revisions 6/27/2024 C L E V E L A N D B L V DPROPERTY LINEPROPERTY LINE(E) CONCRETE SIDWALK(E) ASPHALT PARKING LOTPROPERTY LINEPROPERTY LINEW I L S O N D R A I N3 8 T H A V E N U E(E) FAILING ASPHALT & GRAVEL YARDTREES TO BE REMOVED(E) 1,100 SF PARTS STORAGE SHOPBUILT 1978(E) 980 SF RETAIL STOREBUILT 1978(E) 600 SF STORAGE BUILDINGBUILT 2022(E) 800 SFDETACHED GARAGE BUILT 1978(E) 600 SF SHOP STORAGEBUILT 2021(D) CHAINLINK FENCE & GATE(E) DRIVE ENTRY(E) DRIVE ENTRY(E) ASPHALT & PARKING CONTINUE INTO ADJACENT PROPERTY(E) DRIVE ENTRYAPPROXIMATE LAYOUT/USE OF EXISTING PARKING LOT STALLSAPPROXIMATE LAYOUT/USE OF EXISTING PARKING LOT STALLSAPPROXIMATE LAYOUT/USE OF EXISTING PARKING LOT STALLSAPPROXIMATE LAYOUT/USE OF EXISTING PARKING LOT STALLSAPPROXIMATE LAYOUT/USE OF EXISTING PARKING LOT STALLS(E) ASPHALT STORAGE YARDNO PUBLIC ACCESS(E) GRAVEL ROAD(E) POWER POLE(E) POWER POLE, ELECTRICAL METERS & DISCONNECTS(E) LIGHT POLE(E) LIGHT POLE(E) CHAINLINK FENCE TO REMAIN(D) CHAINLINK FENCE & GATE(E) WATER METER(D) CHAINLINK FENCE & GATE(E) POWER POLE(E) POWER POLES(E) LIGHT POLE(E) POWER POLE & LIGHT POLE(E) SIGN POLE(E) LIGHT POLE(E) CROSSWALK & CURB RAMP(E) 1,130 SF SHOPBUILT 1978(D) CHAINLINK FENCE(E) CHAINLINK FENCE & GATE(E) CHAINLINK FENCE TO REMAINA3.12A3.1A3.1A3.1134C L E V E L A N D B L V DPROPERTY LINEPROPERTY LINE(E) CONCRETE SIDWALKPROPOSED PARKINGNO PRODUCTS IN REQUIRED PARKING STALLS(N) PRE-ENGINEERED METAL BUILDINGPROPERTY LINEPROPERTY LINEW I L S O N D R A I N3 8 T H A V E N U E(E) GRAVEL YARDLOCATION OF NEW DRIVE(E) 800 SF DETACHED GARAGE197820'-0" 1'-0" 24'-0" 180'-0"31'-7"2" / 1'-0"2" / 1'-0"120'-8"64'-3"6'-0"69'-8"20'-2 1/32"(N) CONCRETE SIDEWALK CURB & GUTTER(E) ACCESSIBLE CURB RAMP(E) DRIVE ENTRY TO REMAIN39'-7"19'-5"32'-0"25' ARTERIAL LANDSCAPE BUFFER40' CLEAR VISION TRIANGLE10' LOCAL LANDSCAPE BUFFER25'-0"(E) ENTRY DRIVE36'-0"(E) ASPHALT & PARKING CONTINUE INTO ADJACENT PROPERTY20'-0" 24'-0" 27'-0"(E) ASPHALT TO BE SAW-CUT, RESURFACED AND STRIPED(E) ASPHALT13'-0"20'-0"9'-0"(E) OVERHEAD POWER POLE24'-0"(N) 6' CHAINLINK FENCE & GATE WITH VINYL SLATS, TYP.(E) POLE SIGN(E) LIGHT POLECLEAR VISION TRIANGLE(N) SOD, TYP.(N) SOD, TYP.(N) SOD, TYP.PROPOSED PARKING NO PRODUCTS IN REQUIRED PARKING STALLS(N) ASPHALTMAINTAIN 20' DIA. PERVIOUS LANDSCAPING AROUND BASE OF (E) TREE(N) 2" CALIPER CLASS I CANADA RED CHOKE-CHERRY TREE, TYP.(N) SPIREA BUSHES, TYP.(N) 2" CALIPER CLASS I CANADA RED CHOKE-CHERRY TREE, TYP.(N) SPIREA BUSHES, TYP.(E) GRAVEL ROAD(E) POWER POLE(E) POWER POLE, ELECTRICAL METERS & DISCONNECTS(E) LIGHT POLE(E) LIGHT POLE(E) CHAINLINK FENCE(E) POWER POLE(E) POWER POLES(E) LIGHT POLE(E) WATER METER(E) 600 SF SHOP STORAGE 2021(E) 1,100 SF PARTS STORAGE SHOPBUILT 1978(E) 980 SF RETAIL STOREBUILT 1978(E) 1,130 SF SHOPBUILT 1978(E) 600 SF STORAGE BUILDING 2022PROPOSED PARKING NO PRODUCTS IN REQUIRED PARKING STALLS(N) 6' CHAINLINK FENCE10'-0"Project numberDateDrawn byChecked by280 N. 8th Street, Studio 204,Boise, Idaho 83702erik@erikhagen.com 310.755.5987Copyright © 2023 Erik Hagen, Architect PLLCProject status6/27/2024 5:25:05 PMA0.1Site Plans23493718 Cleveland Blvd, Caldwell ID 83605Alfredo & Edgar Escobedo6/27/2024ErikErikAlfredo Auto Sales Storage BuildingPlanning Revisions1" = 20'-0"1Site Plan Existing1" = 20'-0"2Site Plan Proposed0'10'20'40'80'PROJECT NORTHTRUE NORTH0'10'20'40'80'PROJECT NORTHTRUE NORTHNo. Description Date1 Planning Application 4/2/20242 Planning Revisions 6/27/2024 WH432156DCBA54 SFRestroom6875 SFStorageWarehouse1.15.9C.9A.15'-0" 4'-4" 31'-8" 14'-0" 5'-0"12'-0" 12'-0" 12'-0" 12'-0" 12'-0" 12'-0" 12'-0" 12'-0" 12'-0" 12'-0"4"8'-0"8'-0"WALL HUNG LAVATORYUTILITY SINKACCESSIBLE CLEARANCES, TYP.UNCONDITIONED4" REINFORCED CONCRETE SLAB ON GRADEOVERHEAD DOOR, TYP.PEMB STRUCTURAL COLUMN, TYP.PEMB METAL PANEL ON Z-GIRT6A5.16A5.17A5.17A5.18A5.1432156DCBA1.15.9C.9A.16875 SFStorageWarehouse54 SFRestroomEQ 29'-4" EQ15'-5" 29'-6" 29'-6" 29'-6" 15'-5"3'-4" 52'-0" 3'-4"VERTICAL STRUCTURE HUNG SPACE HEATER UNIT, TYP.PENDANT HUNG INDUSTRIAL LED FIXTURE, TYP.SURFACE MOUNTED LINEAR LEDEXHAUST FANSUPPLY AIR DIFFUSEREXTERIOR WALL PACK AT 10' A.F.F., TYP.PEMB Z-PURLIN, TYP.PEMB BEAM, TYP.6A5.17A5.18A5.1Project numberDateDrawn byChecked by280 N. 8th Street, Studio 204,Boise, Idaho 83702erik@erikhagen.com 310.755.5987Copyright © 2023 Erik Hagen, Architect PLLCProject status6/27/2024 5:25:07 PMA1.1Proposed Plans23493718 Cleveland Blvd, Caldwell ID 83605Alfredo & Edgar Escobedo6/27/2024ErikErikAlfredo Auto Sales Storage BuildingPlanning Revisions1/8" = 1'-0"1Proposed Floor Plan0'4'8'16'32'PROJECT NORTHTRUE NORTHGENERAL NOTES:1. NOTE EVERY ITME IS NOTED OR DIMENSIONED. NOTES & DETAILS ARE TYPICAL & SHOULD BE CONSIDERED DUP[LICATED WHERE NOT NOTED OR DIMENSIONED.2. CONTRACTOR TO VERIFY AS-BUILT CONDITIONS PRIOR TO CONSTRUCTION. ANY DISCREPANCIES FOUND SHALL BE BROUGH TO THE ARCHITECTS ATTENTION FOR REVIEW AND RESOLUTION PRIOR TO BUILDING.3. ALL DIMS ARE FACE OF STUD, UNLESS NOTED OTHERWISE.4. DOOR TAGS REPRESENT DOOR SIZE (3070 = 3'-0" X 7'-0" DOOR).A. ROUGH OPENING SHALL BE 2 1/2" WIDER AND 1 1/2" TALLER THAN DOORB. DOORS SHALL BE LOCATED 4" FROM ADJACENT WALL WHERE NOT OTHERWISE INDICATEDC. ALL DOORS TO HAVE LEVER HANDLES5. FURNITURE BY OTHERS, SHOWN FOR INFORMATIONAL PURPOSES ONLY6. ALL WALLS TO BE ANCHORED TO THE FLOOR w/ 1/2" KBTZ OR EQUAL @ 24" O.C. AND BRACED AT THE CEILING W/ CEILING JOISTS, OR ALTERNATING LEG BRACES TO THE DECK ABOVE @ 48" O.C.7. ALL WALLS 9'-0" TALL, UNLESS NOTED OTHERWISE, W/ DRYWALL TO BE 5/8" TYPE X8. CEILINGS TO BE MOUNTED DIRECTLY TO THE UNDERSIDE OF JOISTS, UNLESS NOTED OTHERWISEABBREVIATIONS:CLG: CEILINGHDR: HEADERFTG: FOOTINGCFCI: CONTRACTOR FURNISHED, CONTRACTOR INSTALLEDOFCI: OWNER FURNISHED, CONTRACTOR INSTALLEDOFOI: OWNER FURNISHED, OWNER INSTALLEDTBD: TO BE DETERMINEDTYP: TYPICALRO: ROUGH OPENINGDO: DO OVER / REPEAT*T TEMPERED GLAZINGTOF TOP OF FOOTINGTOC: TOP OF CONCRETETOW: TOP OF WALLUNO: UNLESS NOTED OTHERWISE1/8" = 1'-0"2Proposed Ceiling Plan0'4'8'16'32'PROJECT NORTHTRUE NORTHNo. Description Date1 Planning Application 4/2/2024 Ground Floor0"ToS18'-8"Top of Stem4'-0"6A5.1Ground Floor0"ToS18'-8"Top of Stem4'-0"7A5.18A5.1Ground Floor0"ToW15'-0"Bot of Fnd-2'-0"ToS18'-8"10'-0"10'-0"Bot of Eave16'-0"Top of Stem4'-0"6A5.1Ground Floor0"ToW15'-0"Bot of Fnd-2'-0"ToS18'-8"10'-0"10'-0"Bot of Eave16'-0"Top of Stem4'-0"7A5.18A5.1Project numberDateDrawn byChecked by280 N. 8th Street, Studio 204,Boise, Idaho 83702erik@erikhagen.com 310.755.5987Copyright © 2023 Erik Hagen, Architect PLLCProject status6/27/2024 5:25:08 PMA3.1Proposed ExteriorElevations23493718 Cleveland Blvd, Caldwell ID 83605Alfredo & Edgar Escobedo6/27/2024ErikErikAlfredo Auto Sales Storage BuildingPlanning Revisions0'4'8'16'32'GENERAL NOTES:1. NOTE EVERY ITME IS NOTED OR DIMENSIONED. NOTES & DETAILS ARE TYPICAL & SHOULD BE CONSIDERED DUP[LICATED WHERE NOT NOTED OR DIMENSIONED.2. CONTRACTOR TO VERIFY AS-BUILT CONDITIONS PRIOR TO CONSTRUCTION. ANY DISCREPANCIES FOUND SHALL BE BROUGH TO THE ARCHITECTS ATTENTION FOR REVIEW AND RESOLUTION PRIOR TO BUILDING.3. ALL DIMS ARE FACE OF STUD, UNLESS NOTED OTHERWISE.4. DOOR TAGS REPRESENT DOOR SIZE (3070 = 3'-0" X 7'-0" DOOR).A. ROUGH OPENING SHALL BE 2 1/2" WIDER AND 1 1/2" TALLER THAN DOORB. DOORS SHALL BE LOCATED 4" FROM ADJACENT WALL WHERE NOT OTHERWISE INDICATEDC. ALL DOORS TO HAVE LEVER HANDLES5. FURNITURE BY OTHERS, SHOWN FOR INFORMATIONAL PURPOSES ONLY6. ALL WALLS TO BE ANCHORED TO THE FLOOR w/ 1/2" KBTZ OR EQUAL @ 24" O.C. AND BRACED AT THE CEILING W/ CEILING JOISTS, OR ALTERNATING LEG BRACES TO THE DECK ABOVE @ 48" O.C.7. ALL WALLS 9'-0" TALL, UNLESS NOTED OTHERWISE, W/ DRYWALL TO BE 5/8" TYPE X8. CEILINGS TO BE MOUNTED DIRECTLY TO THE UNDERSIDE OF JOISTS, UNLESS NOTED OTHERWISEABBREVIATIONS:CLG: CEILINGHDR: HEADERFTG: FOOTINGCFCI: CONTRACTOR FURNISHED, CONTRACTOR INSTALLEDOFCI: OWNER FURNISHED, CONTRACTOR INSTALLEDOFOI: OWNER FURNISHED, OWNER INSTALLEDTBD: TO BE DETERMINEDTYP: TYPICALRO: ROUGH OPENINGDO: DO OVER / REPEAT*T TEMPERED GLAZINGTOF TOP OF FOOTINGTOC: TOP OF CONCRETETOW: TOP OF WALLUNO: UNLESS NOTED OTHERWISE1/8" = 1'-0"2East1/8" = 1'-0"1North1/8" = 1'-0"3West1/8" = 1'-0"4South0'4'8'16'32'0'4'8'16'32'0'4'8'16'32'No. Description Date1 Planning Application 4/2/2024