HomeMy WebLinkAboutRiver Bluff_FP_SitePlan_2024-06-07TELETELEGASTRANS TRANS PP PPSSTOE TOETOE TOETOE TOP TOP TOP TOPTOPTOPTOPTOPTOPTOP TOP TOP TOPT
OP
TOP
TOP
TOETOETOETOETOETOE TOE TOE TOETOE
TOETTOP TOPTTOETOEXX XXXXXXX X TOETOE TOETOETOE TOETOE TOE TOETOETOETOETOE TOETOETOE TOE TOE TOE TOE
TOP
FL FL FL FL FL FL FL FL FL FLFLFL
TOE TOETOETOE TOETOETOE TOE TOETOETOETOPTOP TOPTOPTOPTOP TOP TOP TOPTOP TOPXXXX X X XX XX X XXXXXPEPEP EP EPEP EP EPEP EP EPEP EP EP EP EPEPEPEP EP EP EPEP EPEP EP EP EPEP EP EPEP EPXX X X X X XXX XX X X X X XXX X X X XWPOW POWPOW POW POW POW POW POW POW POW POW POWSS SSSSSSSS TOP TOP TOPTOP TOP TOP TOP TOP TOP TOPTOPTOPTOP TOPTOP TOP TOP TOP TOP TOP TOP TOPTOPSS MANHOLERIM ELEV = 2401.86IE S IN = 2386.87IE E OUT = 2386.82N89°43'16"W - 562.94'N00°11'34"E - 877.41'
S00°16'47"W - 878.09' S89°47'26"E - 564.27'EP EP EP
EP EP EP EP EP EP
PIRR PIRR PIRR PIRR PIRR
E
P
EPEPEPEP
ROW PIRR PIRR PIRR PIRR PIRR PIRR PIRR PIRR WWWWWW W W W WWWW W W WW W W W W W W W W
W W W W W W W W W W W W W W W W W WSS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSS SS SSSSSS SS SS SS ssss ssSSSSSS SSWW W W W WW W W W W WSSSSSS PIRRPIRR PIRR PIRR PIRR PIRR PIRR ROW ROW ROW ROW ROW ROW ROW ROW PIRRPIRR PIRR
S
D
W W W WGIRR GIRR GIRR
ssEP EPEP EPEP EP SDSDSD SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSW W W W W W W W W W W W W
SSSSPIRR PIRR PIRR
ROW
ROW
ROWROW WM WM WM WM SSPIRR PIRR PIRR PIRR PIRR PIRR PIRR PIRRPIRR PIRR
PIRR PIRR PIRR PIRR PIRR PIRR PIRR PIRR PIRR PIRR PIRR PIRR PIRR PIRR PIRR PIRR ROWPI PI WM
PI
PIPI PI PI PI PI PI PI PIPI PI PI PI PIPI PI GIRRGIRR GIRR GIRR PIRRPIPIWWMWMPIRRPI PIssssssss PI WWWM WMWWWMWM WWM GIRRGIRR GIRR GIRR GIRR GIRR GIRR GIRR GIRR WWM
WWWM WM
WW WM WM SSSSWWWMWM WWM WWM
(SCALE IN FEET)
1:50 (22x34 FULL SIZE) 50 25 150500
UTILTIY PLAN
8" GATE VALVE (MJxMJ) W/ PLUG END OF
WATER LINE (NORTH SIDE OF TEE)
8" MJxFLG ADAPTER SOUTH SIDE OF TEE
131.0 LF OF 8" C900 WATER MAIN
8"x8"x8" TEE
(MJxMJxFLG)
122.6 LF OF 8"
C900 WATER MAIN
15.0 LF 6" C900
WATER LINE
272.0 LF OF 8" C900 WATER MAIN
FLG 90° ELBOW W/
THRUST BLOCK
FIRE HYDRANT
EXISTING MANHOLE REVISE RIM.
OLD RIM 2402.06
NEW RIM 2399.88
INV OUT EL (S) 2393.99
INV IN EL (N) 2394.09
CITY SUPP SPEC SS-501, SS-501A, & ISPWC
SD-507 STANDARD MANHOLE TYPE A.
RIM 2402.93
INV OUT EL 2396.82
STANDARD MANHOLE TYPE A
RIM EL 2399.43
INV IN EL (W) 2394.73
INV IN EL (N) 2394.39
INV OUT EL (S) 2394.29
145.9 LF - 8" SEWER MAIN PIPE -
ISPWC - SECTION 501 PART 2.2.
SLOPE 0.62%
337.5 LF - 8" SEWER MAIN PIPE - ISPWC -
SECTION 501 PART 2.2. SLOPE 0.62%44.6 LF - 8" SEWER MAIN PIPE -ISPWC - SECTION 501 PART 2.2.SLOPE 0.45%FIRE HYDRANT
14.0 LF 6" C900 WATER LINE
8"x8"x6" TEE (MJxMJxFLG)
6" GATE VALVE (FLGxMJ)
MASON VIEW PLACE RIVER BLUFF COURTSEWER SERVICES TO EXTEND
THROUGH THE FRONT LOT
LINE EASEMENT, TYP
8" GATE VALVE (MJxMJ)
8" GATE VALVE (MJxMJ)
70 LF 8" C900 WATER LINE
10.32'12.00'EXISTING SEWER SERVICE TO REMAINALL OTHER SEWER SERVICESNEW UNLESS LABELED EXEXISTING 2" WATER SERVICE TO REMAIN,OUTSIDE OF ROADWAY CUT LINE AND PLACEBRASS COMPRESSION FITTING TO REDUCE TO 1"ALL OTHER WATER SERVICES NEW UNLESS LABELED EX.34" - 1" WATER SERVICE WITH WATER METER PLACED WITHIN ROW AND OUTSIDE SIDEWALK PER STD DWG W-413EXISTING SEWER SERVICEEXISTING 2" WATER SERVICE TO REMAIN, BRASSCOMPRESSION FITTING TO REDUCE TO 1"EXISTING SEWER SERVICECITY SUPP SPEC SS-501A & ISPWC
SD-507.
BASE 1.33' (DEPTH)
FLAT LID 12" (DEPTH)
COLLAR 8" (DEPTH)
RIM 2398.36
INV OUT EL 2395.29249 LF 8" C900
WAT
E
R LI
N E
REFER TO WATER NOTES 3 FOR
WATER SERVICE CROSSING, TYP
REFER TO WATER NOTES 2 FOR
WATER MAIN CROSSING, TYP
ALL OTHER SEWER
SERVICES GRAVITY
PRESSURE SEWER PIPE STUB
INTO THE PROPERTY, TYP FOR 2
LOTS IDENTIFIED. GRINDER PUMP
TO BE LOCATED AT THE HOUSE
AND OWNED / OPERATED BY THE
PROPERTY OWNER.
4" SEWER PIPE MIN. 2% SLOPE. INSTALL
TYPE A SEWER SERVICE PER ISPWC
SD-511 AND ISPWC-SECTION 504, TYP
4" SEWER PIPE AND CONSTRUCT
4" SEWER CLEAN OUT AS SHOWN,
MIN. 2% SLOPE. INSTALL TYPE A
SEWER SERVICE PER ISPWC
SD-511 AND ISPWC-SECTION 504,
TYP
8" ISOLATION VALVE
NORTH SIDE OF TEE
AT PROPERTY LINE REMOVE EX WATER
MAIN BACK TO MASON VIEW PLACE
CONNECT TO EX
W/ FLG 45° ELBOW 15.00' WATERLINE EASEMENT8"x8"x6" TEE (MJxMJxFLG)
6" GATE VALVE (FLGxMJ)
REMOVE ANGLE AND EX WATER MAIN TO THE WEST,
NEW WATER MAIN TO THE NORTH TO TIE INTO END
OF EX WATER MAIN WITHIN MASON VIEW PL
EXIST
ING
2" WA
TER
SERVI
CE TO
REMAIN
,
BRASSCOMPRESSION
FIT
T
ING
TO
REDUCE TO
1
"
MH STRUCT #4
MH STRUCT #2
MH STRUCT #1
MH STRUCT #3
STREET NAME SIGN
EXISTING
STREET NAME SIGN
STOP SIGN
DEAD END SIGN
EX WATER MAIN TO BE
ABANDONED IN PLACE
January 2023
PLOTTED BY: CALEB KENYON DATE PLOTTED: 1/20/2023 4:32:43 PM PATH: A:\ABCO ENGINEERING\JOBS LANDED\CALEB\190223--LINCOLN CHARTER SCHOOL (MUSSELL)\ZSUBDIVISION\CAD\190223S - 03 - CU-101.DWGFILE NUMBER:
SHEET NUMBER:
DESIGNED BY:
DATEDESCRIPTIONDATE REVISIONSBY NO. DRAWN BY:ABCOENGINEERING119 N. Midland Blvd.
Nampa, Idaho 83651
Phone (208) 955-8126
LINCOLN STREETC. KENYON
CU-101CALDWELL ID UTILITY PLANMUSSELL CONSTRUCTION3 OF 7 CANYON COUNTY RIVER BLUFF SUBDIVISIONC. KENYON
190223S
CALL BEFORE YOU DIG!
1. THE LOCATION OF EXISTING UNDERGROUND UTILITIES SHOWN
ARE APPROXIMATE LOCATIONS ONLY. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO INFORM ALL UTILITY
COMPANIES OF THE CONSTRUCTION SCHEDULE. THE
CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL
EXISTING UTILITIES BEFORE COMMENCING WORK. THE
CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL DAMAGE
WHICH MAY OCCUR BY FAILURE TO EXACTLY LOCATE AND
PROTECT ALL UTILITIES.
2. CONTRACTOR SHALL CONTACT DIGLINE 48 HOURS PRIOR TO ANY
EARTH DISTURBING ACTIVITIES ON SITE, AND REQUEST LOCATE OF
UNDERGROUND UTILITIES.
*The 811 logo is a registered trademark of the CGA.
Know what'sbelow.
before you dig.CallR
1. CONSTRUCTION OF THE WATER SYSTEM SHALL CONFORM TO THE
STANDARDS IN THE "IDAHO RULES FOR PUBLIC DRINKING WATER
SYSTEMS (IDAPA 58.01.08)" AS WELL AS THE STANDARDS AND
SPECIFICATIONS REFERRED TO IN GENERAL CONSTRUCTION NOTE NO.
1.
2. THE HORIZONTAL SEPARATION OF POTABLE WATER MAINS AND
NON-POTABLE WATER MAINS (SANITARY SEWER, STORM DRAIN, AND
IRRIGATION) SHALL BE A MINIMUM OF TEN (10) FEET. WHERE IT IS
NECESSARY FOR A POTABLE WATER MAIN AND NON-POTABLE WATER
MAIN TO CROSS WITH LESS THAN EIGHTEEN (18) INCHES OF VERTICAL
SEPARATION, THE CROSSING SHALL BE CONSTRUCTED IN ACCORDANCE
WITH SECTION 542.07 OF THE IDAHO RULES FOR PUBLIC DRINKING
WATER SYSTEMS (IDAPA 58.01.08) AND SECTION 430.02 OF THE
WASTEWATER RULES (IDAPA 58.01.16).
3. THE HORIZONTAL SEPARATION OF NON-POTABLE SERVICES AND
POTABLE WATER SERVICES OR POTABLE WATER MAINS SHALL BE A
MINIMUM OF SIX (6) FEET. WHERE IT IS NECESSARY FOR A POTABLE
WATER MAIN AND NON-POTABLE WATER MAIN TO CROSS WITH LESS
THAN EIGHTEEN (18) INCHES OF VERTICAL SEPARATION, THE CROSSING
SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION 542.07 OF THE
IDAHO RULES FOR PUBLIC DRINKING WATER SYSTEMS (IDAPA 58.01.08)
AND SECTION 430.02 OF THE WASTEWATER RULES (IDAPA 58.01.16).
4. PLACE WATER SERVICE LINES IN A TWO (2) INCH DIAMETER PIPE
WHEREVER THE SERVICE LINE CROSSES A STORM WATER TREATMENT
FACILITY (I.E. SEEPAGE BEDS, DRAINAGE SWALES). THE PIPE MATERIAL
USED FOR SLEEVING MUST BE IMPERVIOUS TO CONTAMINATION FROM
PETROLEUM PRODUCTS AND MUST BE APPROVED BY THE IDAHO
DEPARTMENT OF ENVIRONMENTAL QUALITY (IDEQ).
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING
CONTINUOUS WATER SERVICE TO ALL EXISTING WATER USERS
AFFECTED BY CONSTRUCTION.
6. ALL WATER WORKS COMPONENTS SHALL BE ANSI/NSF 61 CERTIFIED,
AND MUST MEET ALL AWWA AND STANDARD REQUIREMENTS OF THE
IDAHO RULES FOR PUBLIC DRINKING WATER SYSTEMS (IDAPA 58.01.08).
WATER NOTES
SEWER NOTES
1. CONSTRUCTION OF THE SEWER SYSTEM SHALL CONFORM TO THE
STANDARDS IN THE WASTEWATER RULES (IDAPA 58.01.16 AS WELL AS
THE STANDARDS AND SPECIFICATIONS REFERRED TO IN GENERAL
CONSTRUCTION NOTE NO. 1.
2. SEE WATER NOTES FOR SEPARATION OF POTABLE AND NON-POTABLE
SERVICES RULES.
3. PLACE SEWER SERVICE LINES IN A SIX (6) INCH DIAMETER WATER
CLASS PIPE WHEREVER THE SERVICE LINE CROSSES A STORMWATER
TREATMENT FACILITY (I.E., SEEPAGE BEDS, DRAINAGE SWALES).
4. WHEN COVER OVER A SEWER PIPE IS LESS THAN THREE (3) FEET FROM
TOP OF PIPE TO SUBGRADE OR TOP OF PIPE TO NATURAL GROUND,
USE "CLASS 200 WATER PRESSURE PIPE", ASTM D 2241, SDR 21,
INCLUDING SERVICE LINES AND FITTINGS.
4x6
C
L
E
A
R
S
P
A
C
E
F
O
R
CI
T
Y
A
P
P
R
O
V
A
L
S
T
A
M
P
City of Caldwell
APPROVED FOR CONSTRUCTION
These plans and/or specifications have
been reviewed for compliance with the City
of Caldwell specifications. This review
does not relieve the owner, engineer, or
contractor of the responsibility to design
and/or construct these facilities in
compliance with all current applicable
federal, state, and local laws, rules,
regulations, ordinances, orders of
decisions, development agreements, or
specifications. Inconsistencies not
isolated by City staff shall not be
construed as approved unless specifically
addressed as a variance and granted by
City Council as a variance. The City
retains the right to enforce provisions of
said document and policies even if
inconsistencies are not noted by the City.
Any revisions of these approved plans will
require a resubmittal for a full review and
approval.
Name: