HomeMy WebLinkAbout0 Pewter Point_Calculations_2024-05-22THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRIC CODEAND/ON OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGNSCALE 3/4” = 1’-0”
10’-0”
10’-4”
8”
1’-0”1’-0”3’-0”SINGLE FACE ENTRY DISPLAY WITH HALO ILLUMINATED PAN CHANNEL LETTERS
NIGHT VIEW
STRUCTURE FABRICATION
PER A211 (2) - BY OTHERS
TOP
ROUGH-CUT DOUGLAS FIR WOOD BEAM
STAINED SW 3007 “LODGE BROWN” SOLID
ANCHORED TO CMU
HALO LETTERS
FACES - ROUTED OUT .080 ALUMINUM, PAINTED DARK BRONZE
RETURNS - 2” .063 ALUMINUM COIL, PAINTED DARK BRONZE
HALO ILLUMINATION WITH WHITE LED’s
WIREWAY INSTALLED ON BACK OF STRUCTURE
PAINTED TO MATCH
ATTACH BEAM USING
(3) 1” x 12” GALV STUDS
TEMPLATE AND STUDS
PROVIDED BY SIGN CO
INSTALLED BY MASON AT
TIME OF CONCRETE
3/16 x 4” STUD
EMBEDDED 2-1/2” INTO CMU
COATED WITH SILICONE
MIN (4) PER LETTER
WIREWAY