To: Katie Wright, Associate Planner
Caldwell P & Z Department
From: TJ Frans, Project Manager
Steven Pendleton, Civil Plans Examiner II
Re: ANN23-000010 / CPM23-000007 / SUB23-000013 (Tranquil Acres)
Date: November 9, 2023
The Engineering Department provides the following comments on a request by HECO
Engineers, on behalf of Harland Backer, is requesting a comprehensive plan land use map
amendment from MDR (Medium Density Residential) to HDR (High Density Residential), as well
as annexation with a zoning designation of R-3 (High Density Residential), to include approval
of Resolution # 167-23 associated with CPM23-000007. The applicant is also applying for a
subdivision preliminary plat for Tranquil Acres Subdivision, which includes thirty townhome units
and one single family detached unit for a total of (31) single family residential units. At 3.5 acres,
the total density is 8.8 units per acre; the site is located at 0 Montana Ave., on the east side of
S. Montana Avenue, approximately 1,300 feet north of the intersection with Ustick Road in
Caldwell, Idaho.
Development Plans
1. Development Plans – Prior to commencing construction and applying for building permits,
plans must be prepared by the developer’s engineer and approved by the City Engineering
Department which shall include the following items:
a. Street section and alignment (including curb and gutter);
b. Sidewalk (sidewalk width based on street classification);
c. Sanitary sewer (per City and DEQ requirements);
d. Potable water (per City and DEQ requirements);
e. Stormwater facilities (per City requirements/storm water manual);
f. Street lighting (per City standards);
g. Street signage (per City and MUTCD requirements);
h. Vertical Datum based on NAVD 88 Datum.
Tranquil Acres
ANN23-000010 / CPM23-000007 / SUB23-000013
Page 2 of 6
General
1. Easements for Public Utilities shall be 10 feet wide minimum along all front lot lines. A
minimum10 feet wide easement (or larger if deemed necessary by the City Engineer in order to
facilitate future maintenance operations of utilities) may be required along select interior lot
lines to facilitate pressure irrigation or other utilities.
2. Appropriate easements for emergency access, transmission lines and/or other utilities shall be
clearly indicated, with recorded instrument numbers provided for said easements, on the face
of the final plat (visually and in writing). Existing easements shall be shown on all construction
drawings.
3. All utilities on and within the boundaries of the subdivision shall be located and/or relocated
underground.
4. All street, sewer, water, fire protection, and street light facilities must be dedicated to the City.
Some conveyance facilities for stormwater drainage may be eligible for dedication to the City.
5. Construction of facilities to be dedicated and/or within public right-of-way shall be performed by
an appropriately licensed public works contractor and shall be inspected by and constructed to
City of Caldwell specifications.
6. Prior to commencement of construction in any dedicated right-of-way, or construction of any
improvement intended for dedication to the City or connected to a City facility, the City
Engineering staff is to be notified. This preferably will take place in a pre-construction
conference scheduled by the engineer of record in which all appropriate personnel and utilities
are present. Appropriate City personnel are to be notified in advance of all testing (including
compaction, pressure and coliform, etc.) and given opportunity to be present during conduct of
the testing. The engineer of record or his designated representative is to witness all tests (not
covered by City inspectors) and a log of inspection visits and testing results is to be kept by the
engineer of record or his representative.
7. The developer is to employ a responsible design professional, preferably the engineer of
record, to oversee and inspect construction, to perform and/or observe all requisite testing of
completed facilities, and to certify that improvements have been constructed according to
approved plans and in compliance with applicable City, State, and Federal standards.
8. The engineer of record shall be held responsible to ensure that subdivision improvements are
in substantial compliance with said engineer’s design. Following the construction of the
subdivision improvements, the developers engineer shall provide the City of Caldwell
Engineering Department with electronic (.dwg) format record drawings spatially referenced to
the Idaho State Plane Coordinate System-West Zone, North America Datum (NAD) 83. Vertical
control shall be referenced to the North America Datum (NAVD) 88 for future reference and to
establish that the engineer of record has caused construction to occur in substantial
compliance with the design of said engineer of record.
9. Any note, item or drawing element on the plats, construction drawings, engineering drawings
and/or design drawings related to the property inconsistent with City Codes, Policies and/or
Ordinances shall not be construed as approved unless specifically addressed and granted by
City Council.
Tranquil Acres
ANN23-000010 / CPM23-000007 / SUB23-000013
Page 3 of 6
Rights-of-Way
1. S. Montana Ave. is classified as a Collector. The applicant shall dedicate as public right-of-way
a minimum thirty-five (35’) foot half width right-of-way (from centerline/section line) along the
entire S. Montana Ave. alignment (per City Standard R-810 C).
2. All interior local streets classified as residential shall be dedicated to the City. The applicant
shall dedicate as public right-of-way a minimum fifty-three (53) foot full width right-of-way (per
City Standard R-810 E).
Street
1. Full street improvements shall be completed to all roads adjacent to the proposed project
(including S. Montana Ave. and College Ave.) in accordance with all City of Caldwell standards
and specifications. Improvements shall include (but are not limited to) curb, gutter, sidewalk,
asphalt, streetlights, joint trench, spare communication conduit along classified roadways,
storm drainage facilities, etc.
2. Applicant shall be responsible to complete the west side surface improvements across the
existing bridge structure over the Dixie Drain in alignment with College Ave. Applicant shall
make appropriate tie in to exist curb gutter and sidewalk south of this crossing.
3. Applicant shall be responsible to construct north east ¼ share of the bridge structure and
surface improvements for Montana Ave. at the Dixie Drain in compliance with a Collector
roadway. Applicant may be able to contribute monies in lieu of construction at the discretion of
the City Engineer.
4. No lot/building shall have direct access to/from S. Montana Ave.
5. Applicant shall coordinate with the United States Postal System to determine a cluster mailbox
unit location. Said location shall be interior to the site and shall be located in a manner that will
not impact, or cause queueing onto, S. Montana Ave. said location shall be approved by the
Engineering Department during construction drawing plan review and prior to plan approval.
Outparcels
1. 3607 S. Montana Avenue (R3573500000)
a. If the City is able to obtain sufficient right-of-way along the frontage of this out parcel
located in the northwest corner of the development the applicant shall complete the
road widening improvements referenced in the Street section, item 1, across the
Montana Avenue frontage of said out parcel. If the City is not able to acquire the right-
Tranquil Acres
ANN23-000010 / CPM23-000007 / SUB23-000013
Page 4 of 6
of-way, lesser improvements may still be required that fall within the prescriptive right-
of-way adjacent to the out parcel.
2. 3705 S. Montana Avenue (R3573200000)
a. If the City is able to obtain sufficient right-of-way along the frontage of this out parcel
located in the southwest corner of the development the applicant shall complete the
road widening improvements referenced in the Street section, item 1, across the
Montana Avenue frontage of said out parcel to the northern easement line of the Dixie
Drain. If the City is not able to acquire the right-of-way, lesser improvements may still
be required that fall within the prescriptive right-of-way adjacent to the out parcel.
Water
1. All on site water mains will need to be looped into existing mains and have a minimum of two
points of connection for fire flow and water quality purposes. Internal main sizing and
construction plan approval, will be dependent upon the availability of fire flow.
2. Each buildable lot or building shall be supplied with potable water. If buildings are constructed
to include individual units that could feasibly or will be sold separately, each unit shall be
serviced separately
3. The location of water service, including sizing of mains, providing of easements, frontage
construction, and offsite construction are to be decided during review of improvement plans.
Sanitary Sewer
1. It shall be the responsibility of the applicant’s engineer to verify that connection to existing sewer
mainlines will not exceed the functional capacity of said mainlines. Provision for connectivity by
future developments shall be met in accordance with current City standards.
2. Each buildable lot or building shall be provided with individual sewer service. If buildings are
constructed to include individual units that could feasibly or will be sold separately, each unit shall
be serviced separately.
3. Any easements for sewer lines not in the right-of-way should be at a width sufficient to construct
same and not less than 20 feet in width. Easements for adjacent sewer and water lines not in the
right-of-way shall be at a width sufficient to construct the same and shall be no less than 30 feet
in width.
4. A 20’ wide all-weather surfaces may be required to be constructed over mainlines that fall outside
the public right-of-way. All weather surfaces shall be constructed sufficiently to support heavy
equipment necessary to construct and maintain sewer under all seasonal weather conditions.
Irrigation
Tranquil Acres
ANN23-000010 / CPM23-000007 / SUB23-000013
Page 5 of 6
1. Existing easements and/or right-of-ways for any irrigation facility shall be determined and
clearly indicated on the construction plans. Construction across or re-routing of these facilities
is subject to approval by the Governing Irrigation District and at their discretion or their assigns.
2. The Developer shall maintain any existing upstream drainage rights and downstream irrigation
rights across the property. During the design phase of this project, the developer or his
engineer is to contact the appropriate irrigation district to help ascertain these rights.
Appropriate facilities shall be provided by the developer to convey irrigation and drainage water
across the property to take care of these offsite needs. There is to be no discharge of
gravity/pressure irrigation return water into the projects storm water system.
2. The development is to include a non-potable water pressure irrigation system. The design of
this pressure irrigation system is to be reviewed and approved by the Caldwell Municipal
Irrigation District prior to construction plan approval. It shall be required that the system will be
operated and maintained by the Caldwell Municipal Irrigation District.
3. Each lot, or building area, shall be provided with a pressure irrigation service in compliance with
Caldwell Municipal Irrigation District standards and City code.
4. All pressure irrigation mainlines shall be located in the public right-of-way (per City Standard T-
308)
5. Applicant shall place the pump station in an area that is easily accessible with a recorded
perpetual easement sufficient for convenient access and maintenance of said pump station.
The lot the pump station is positioned on shall be owned and maintained by the home owners
association.
6. The applicant shall ensure that an adequate continuous irrigation supply flow is available to
meet the pressure irrigation system requirements of CMID.
7. The applicant shall transfer a proportionate share of any existing water right(s), except those
held in trust by an irrigation district, to the City of Caldwell for both irrigation and domestic water
supply for the subject development. If this should occur, The City shall assist in registering the
transfer.
8. All plans and construction drawings submitted to the City of Caldwell for review and approval
for any out-of-season irrigation work to be performed within or across facilities located within (or
owned by) irrigation districts other than CMID shall be submitted to the Caldwell Engineering
Department no later than August 15th. Submittal of plans after this date may result in Applicant
not receiving plan approval in time to complete out-of-season work.
Storm Drain
1. As noted previously, provision is to be made for the disposal of stormwater drainage in
accordance with the City Stormwater Management Manual and any updates adopted
subsequent to this application. It is to be noted that retention designs will be denied in most
instances. A copy of this policy is available upon request. The engineer of record is to provide
calculations, which indicate that the assumptions in his stormwater drainage plan comply with
Tranquil Acres
ANN23-000010 / CPM23-000007 / SUB23-000013
Page 6 of 6
the requirements of the stormwater manual. In this case, if a storm water system is existing, the
burden of proof is on the developer to verify the capacity is sufficient for the proposed
development.
2. The applicant shall identify and retain all historical drainage discharge points from the property
for the purpose of draining on-site storm water detention facilities.
3. The applicant shall retain all historic upstream and downstream storm water discharges and
shall not create any adverse impacts pertaining to gravity irrigation water or storm water runoff
to the neighboring properties.
4. Storm water detention basins are required to remain on-site and are to be operated and
maintained by the home owners association.
5. There is to be no discharge of storm water overflow into any irrigation water return/discharge
facility/ditch/pipe/etc.
Plat
1. Prior to approval of the final plat, subdivision facilities must be completed or an appropriate
construction security provided. There may be temporary restrictions to the obtaining of building
permits, even with acceptable construction security, depending on fire protection, emergency
service requirements, and City approval of the sanitary sewer system. A 20% temporary
restriction to obtaining of building permits will be enforced until all facility construction has been
completed, inspected and certified by the Applicants engineer including all punch list items.
2. A note shall be added to the final stating that no lot shall have direct access to/from Montana
Ave.
3. Upon recordation of the plat, the Engineering Department is to be provided with a PDF copy of
the recorded final and 3 full paper set.
4. An electronic (dwg.) copy of the Final Plat suitable for mapping and addressing purposes will
be required with Final Plat application submittal.