HomeMy WebLinkAboutemail PYLON - from applicant 11-7-22THE LOCATION OF THE DISCONNECT SWITCH AFTER INSTALLATION SHALL COMPLY
WITH ARTICLE 600.6(A)(1) OF THE NATIONAL ELECTRIC CODE23’-1”2’-4”15’-11”1’-4”8’-0”15’-9” EMC17’-0” CLADDING18’-0” CABINET19’-0” O.A.L.
DOUBLE FACE INTERNALLY ILLUMINATED PYLON
CABINET
FABRICATED GALVANEALED METAL WITH 3” RETAINERS,
PAINTED BLACK
FACES
WHITE FLEX FACES
GRAPHICS
REVERSE CUT BLACK WITH LIGHT BEIGE VINYL
ILLUMINATION
WHITE LED’s
MESSAGE CENTER
THINKsign 16mm 120x300 MATRIX, 4G COMMUNICATION
CLADDING
TOP & BOTTOM GALVANEALED METAL,
PAINTED DARK GREY AND LT GREY
SUPPORT
ENGINEERING REQUIRED
26” BASE PIPE, PAINTED BLACK
SUP REQUEST TO EXCEED 48 SQFT.SIGN ORDINANCE DOES NOT TAKE INTO ACCOUNTTHE REDUCED VISIBILITY OF ELECTRONIC READERBOARD
SIGNS THAT ARE REQUIRED TO BE HIGHER WHEN
ADJACENT TO I-84.40’-0” O.A.H.10”1/26’-3” EMC10”10’-0” CABINET3’-9”SIGN SHOWN AT 60’ OAH
(C-4 ZONE IS ALLOWED UP TO 90’ OAH)
FUTURE
S
O
U
N
D
W
ALL
THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRIC CODEAND/ON OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGNTHE LOCATION OF THE DISCONNECT SWITCH AFTER INSTALLATION SHALL COMPLY
WITH ARTICLE 600.6(A)(1) OF THE NATIONAL ELECTRIC CODE
CLIENTCANYON CROSSINGLOCATIONSALES REP.DAVEFILE NAMEPYLONDESIGNERJIM WDATE05/30/2017SCALE3/16” = 1’-0”WORKING FOR A SAFER WORLDSALESSIGN OFFARTSIGN OFFPROD.SIGN OFFNOTE: THE COLORS DEPICTED IN THIS DRAWING ARE ONLY REPRESENTATIONS OF THE ACTUAL COLORS.YOUR SALES CONSULTANT WILL PROVIDE SAMPLES OF ACTUAL COLORS.I hereby approve all specifications of the print except as noted.CUSTOMER APPROVALSIGNATURE_________________________DATE______________2/4/2022CALDWELL23’-1”2’-4”15’-11”1’-4”8’-0”15’-9” EMC17’-0” CLADDING18’-0” CABINET19’-0” O.A.L.
DOUBLE FACE INTERNALLY ILLUMINATED PYLON
CABINET
FABRICATED GALVANEALED METAL WITH 3” RETAINERS,
PAINTED BLACK
FACES
WHITE FLEX FACES
GRAPHICS
REVERSE CUT BLACK WITH LIGHT BEIGE VINYL
ILLUMINATION
WHITE LED’s
MESSAGE CENTER
THINKsign 16mm 120x300 MATRIX, 4G COMMUNICATION
CLADDING
TOP & BOTTOM GALVANEALED METAL,
PAINTED DARK GREY AND LT GREY
SUPPORT
ENGINEERING REQUIRED
26” BASE PIPE, PAINTED BLACK
SUP REQUEST TO EXCEED 48 SQFT.SIGN ORDINANCE DOES NOT TAKE INTO ACCOUNTTHE REDUCED VISIBILITY OF ELECTRONIC READERBOARD
SIGNS THAT ARE REQUIRED TO BE HIGHER WHEN
ADJACENT TO I-84.40’-0” O.A.H.10”1/26’-3” EMC10”10’-0” CABINET3’-9”ELECTRONIC MESSAGE CENTER SHOWN AT 98 SQFT,
WITH 48 SQFT ADJACENT FOR COMPARISON
THE 48 SQFT MAXIMUM CREATES A HARDSHIP FOR THIS LOT,
DUE TO THE DECREASED VISIBILITY AT THIS HEIGHT
THE LOCATION OF THE DISCONNECT SWITCH AFTER INSTALLATION SHALL COMPLY
WITH ARTICLE 600.6(A)(1) OF THE NATIONAL ELECTRIC CODE23’-1”2’-4”15’-11”1’-4”8’-0”15’-9” EMC17’-0” CLADDING18’-0” CABINET19’-0” O.A.L.
DOUBLE FACE INTERNALLY ILLUMINATED PYLON
CABINET
FABRICATED GALVANEALED METAL WITH 3” RETAINERS,
PAINTED BLACK
FACES
WHITE FLEX FACES
GRAPHICS
REVERSE CUT BLACK WITH LIGHT BEIGE VINYL
ILLUMINATION
WHITE LED’s
MESSAGE CENTER
THINKsign 16mm 120x300 MATRIX, 4G COMMUNICATION
CLADDING
TOP & BOTTOM GALVANEALED METAL,
PAINTED DARK GREY AND LT GREY
SUPPORT
ENGINEERING REQUIRED
26” BASE PIPE, PAINTED BLACK
SUP REQUEST TO EXCEED 48 SQFT.SIGN ORDINANCE DOES NOT TAKE INTO ACCOUNTTHE REDUCED VISIBILITY OF ELECTRONIC READERBOARD
SIGNS THAT ARE REQUIRED TO BE HIGHER WHEN
ADJACENT TO I-84.40’-0” O.A.H.10”1/26’-3” EMC10”10’-0” CABINET3’-9”ADJACENT APPROVED SIGNS
140 SQFT ELECTRONIC MESSAGE CENTER 170 SQFT ELECTRONIC MESSAGE CENTER
THE LOCATION OF THE DISCONNECT SWITCH AFTER INSTALLATION SHALL COMPLY
WITH ARTICLE 600.6(A)(1) OF THE NATIONAL ELECTRIC CODE23’-1”2’-4”15’-11”1’-4”8’-0”15’-9” EMC17’-0” CLADDING18’-0” CABINET19’-0” O.A.L.
DOUBLE FACE INTERNALLY ILLUMINATED PYLON
CABINET
FABRICATED GALVANEALED METAL WITH 3” RETAINERS,
PAINTED BLACK
FACES
WHITE FLEX FACES
GRAPHICS
REVERSE CUT BLACK WITH LIGHT BEIGE VINYL
ILLUMINATION
WHITE LED’s
MESSAGE CENTER
THINKsign 16mm 120x300 MATRIX, 4G COMMUNICATION
CLADDING
TOP & BOTTOM GALVANEALED METAL,
PAINTED DARK GREY AND LT GREY
SUPPORT
ENGINEERING REQUIRED
26” BASE PIPE, PAINTED BLACK
SUP REQUEST TO EXCEED 48 SQFT.SIGN ORDINANCE DOES NOT TAKE INTO ACCOUNTTHE REDUCED VISIBILITY OF ELECTRONIC READERBOARD
SIGNS THAT ARE REQUIRED TO BE HIGHER WHEN
ADJACENT TO I-84.40’-0” O.A.H.10”1/26’-3” EMC10”10’-0” CABINET3’-9”