Loading...
HomeMy WebLinkAboutCFD Subdivision Review Lexington Sky CPM23-000013 403 Blaine Street  Caldwell, ID 83605  Phone 208-649-1266  Fax 208-455-3014 Date 1/30/2024 Caldwell City – Planning and Zoning Re: Case Number: Lexington Sky CPM23-000013 Dear Morgan Bessaw, Planning & Zoning REQUEST SUMMARY: Application Case Number(s): CPM23-000013, ZON23-000012: Lexington Partners LLC is requesting a comprehensive plan land use map amendment from OS (Open Space) to HDR (High Density Residential), and a rezone from C-2 (Commercial) to R-3 (High Density Residential), for the approximately 0.82 acres Parcel R35287104A0, to include approval of Resolution # 10-24 associated with CPM23-000013. The subject parcel is located on the south side of Thomas Jefferson Street, approximately 824’ east of the intersection of Smeed Pkwy and Thomas Jefferson Street, in Caldwell, Idaho. The Caldwell City Fire Department District has reviewed and can approve the application subject to compliance with all the following code requirements and conditions of approval. Any deviation from this plan is subject to Fire Department approval. Please note that unless stated otherwise, this memo represents the requirements of the 2018 International Fire Code (IFC) as adopted by the Idaho State Fire Marshal’s Office. Conditions: 1. Fire hydrants, capable of producing the required fire flow, shall be located along approved fire lanes. Fire hydrant spacing shall meet the requirements of IFC table C105.1.1 (IFC 507.3, IFC B105.2, IFC C105). 2. Roadway serving a fire hydrant shall be a minimum of 26-feet in width. (IFC D103.1) 3. Dead-end fire apparatus access roads exceeding 150 feet (45 720 mm) in length shall be provided with an approved area for turning around fire apparatus. (IFC 503.2.5) 4. Fire apparatus access roads shall extend to within 150 feet of all portions of the exterior walls of the first story of a building measured by an approved route around the exterior of the building or facility. (IFC 503.1.1) 5. Monument signage for addressing will be required at the entrance and at all intersections within the project. (IFC 505.1) 6. Fire apparatus access roads shall have an unobstructed width of not less than 20 feet and an unobstructed vertical clearance of not less than 13 feet 6 inches. (IFC 503.2.1) 403 Blaine Street  Caldwell, ID 83605  Phone 208-649-1266  Fax 208-455-3014 7. The minimum outside turning radius of a fire apparatus access road shall be 48 feet. The minimum inside turning radius shall be 28 feet. (IFC 503.2.4) 8. Fire apparatus access roads shall have an approved driving surface of asphalt, concrete or other approved driving surface and can support the imposed load of fire apparatus weighing at least 80,000 pounds. Please provide documentation the road surface meets this standard. (IFC D102.1) 9. Fire apparatus access roads shall not exceed 10 percent in grade. (IFC D103.2) 10. Fire hydrants serving building FDC’s (R2 Multiple-family structures) shall be located not more than 150’away from connection point. 11. Where fire apparatus access roads or a water supply for fire protection are required to be installed, such protection shall be installed and made serviceable prior to and during the time of construction except where approved alternative methods of protection are provided. Temporary street signs shall be installed at each street intersection where construction of new roadways allows passage by vehicles in accordance with (IFC Section 505.2. 12. MULTIPLE-FAMILY RESIDENTIAL DEVELOPMENTS D106.1 Projects having more than 100 dwelling units. Multiple-family residential projects having more than 100 dwelling units shall be equipped throughout with two separate and approved fire apparatus access roads. Exception: Projects having up to 200 dwelling units shall have not fewer than one approved fire apparatus access road where all buildings, including nonresidential occupancies, are equipped throughout with approved automatic sprinkler systems installed in accordance with Section 903.3.1.1 or 903.3.1.2 Aerial Fire Apparatus Access Roads 13. D105.1 Where required. Where the vertical distance between the grade plane and the highest roof surface exceeds 30 feet (9144 mm), approved aerial fire apparatus access roads shall be provided. For purposes of this section, the highest roof surface shall be determined by measurement to the eave of a pitched roof, the intersection of the roof to the exterior wall, or the top of parapet walls, whichever is greater. 14. D105.2 Width. Aerial fire apparatus access roads shall have a minimum unobstructed width of 26 ft. (7925 mm), exclusive of shoulders, in the immediate vicinity of the building or portion thereof. 15. D105.3 Proximity to building. One or more of the required access routes meeting this condition shall be located not less than 15 feet (4572 mm) and not greater than 30 feet (9144 mm) from the building, and shall be 403 Blaine Street  Caldwell, ID 83605  Phone 208-649-1266  Fax 208-455-3014 positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approved by the fire code official. 16. D105.4 Obstructions. Overhead utility and power lines shall not be located over the aerial fire apparatus access road or between the aerial fire apparatus road and the building. Other obstructions shall be permitted to be placed with the approval of the fire code official. General Requirement: Fire Department required fire hydrants, access, and street identification shall be installed prior to construction or storage of combustible materials on site. Provisions may be made for temporary access and identification measures. Specific building construction requirements of the International Building Code, International Fire Code and City of Caldwell Code will apply. However, these provisions are best addressed by a licensed Architect at time of building permit application. Regards, Alan Perry Deputy Chief Fire Marshal Caldwell Rural Fire Protection District Aperry@cityofcaldwell.org