Loading...
HomeMy WebLinkAboutFerney Ustick Site Plan-A-1.0± 836.00' PROPOSED LOT LINE MIDDLETON RD.24' COMMON ACCESS DRIVE 6 24' COMMON ACCESS DRIVE ± 283.00'± 283.00'±848.00' 4 25'-0" LANDSCAPE BUFFER15'-0"SETBACK25'-0" LANDSCAPE BUFFER 35'-0" 5'-0" 8'-0" 1024'-0"SHAREDACCESSEASEMENT8 26'-5" 48'-0" R/W 29'-2"SHAREDACCESSEASEMENT20'-0"30'-0"45'-0"55'-0"14'-0"40'-0"45'-0"60'-0"55'-0"BUILDING A 33,425 SQ. FT. BUILDING D 16,200 SQ. FT. BUILDING C 5,109 SQ. FT. 33'-10" 50'-0" 45'-0" 40'-0"45'-0"360'-0" 620'-0"120'-0"Dump StationWash Bay50'-0"20'-0"15'-0" 14'-0"15'-0"15'-0" 20'-0"15'-0" 15'-0"50'-0"SCALE: 1" = 50'-0" P R O P O S E D S I T E P L A N B U I L D I N G A R E A R E C A P OFFICE 256 SF BUILDING A 33425 SF BUILDING B 52630 SF BUILDING C 5190 SF BUILDING D 16200 SF BUILDING E 15525 SF TOTAL 123226 SF S I T E R E C A P TOTAL PROPERTY AREA: 16.4 ACRES PARCEL NUMBER: R3088101100 ZONE:C-3 K E Y N O T E S LINES INDICATE 28' INSIDE RADIUS, 20' WIDE FIRE ENGINE ACCESS. PROPOSED ASPHALT PARKING LOT. SEE CIVIL DRAWINGS. PROPOSED 8' HIGH CHAIN LINK FENCING W/ PRIVACY SLATS. MAINTAIN 6" OFFSET FROM PROPERTY LINES. NEW 8' SIDEWALK. ACCESS GATE. EXISTING KEYLOCK ENTRY. TRASH ENCLOSURE. EXISTING USTICK STORAGE ENTRY. 20' EMERGENCY FIRE ENGINE ACCESS, NO PUBLIC USE. FUTURE ACCESS TO ADJACENT PARCELS. 1 2 3 4 5 6 7 8 9 10 1 11 1 5 93 2 3 10 4 BUILDING B 52,630 SQ. FT. 15'-0" 3 14'-0"7 345'-0" BUILDING E 15,525 SQ. FT. 15'-0" 620'-0" 30'-0" 5 13'-0"D C B A 1 2 3 4 5 6 1 2 3 4 5 6 D C B A A-1.0 SITE PLAN *--*DESCRIPTION- COMMENTSDATEDELTAGUARDIAN BOAT & RV STORAGEHATCH DESIGNARCHITECTURE200 W. 36th ST.BOISE, IDAHO 83714OFFICE: (208) 475-3204FAX: (208) 475-3205THIS PLAN AND/OR DESIGN ARE NOT TO BE CHANGED ORCOPIED IN ANY FORM, NOR ARE THE DOCUMENTS TO BEASSIGNED TO A THIRD PARTY WITHOUT WRITTEN CONSENTAND PROPER COMPENSATION TO HATCH DESIGNARCHITECTURE.THE USE OF THE PLANS SHALL BE RESTRICTED TO THEORIGINAL SITE FOR WHICH THEY WERE PREPARED.DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS,INCLUDING THOSE IN ELECTRONIC FORM, PREPARED BYTHE DESIGNER AND THE DESIGNER'S CONSULTANTS AREINSTRUMENTS OF SERVICE FOR USE SOLELY WITH RESPECTTO THIS PROJECT. THE DESIGNER AND THE DESIGNER'SCONSULTANTS SHALL BE DEEMED THE AUTHORS ANDOWNERS OF THEIR RESPECTIVE INSTRUMENTS OF SERVICEAND SHALL RETAIN ALL COMMON LAW, STATUTORY ANDOTHER RESERVED RIGHTS, INCLUDING COPYRIGHTS.SHEET TITLE SHEET NUMBER SHEETNEW STORAGE UNIT FACILTY FOR:0 MIDDLETON RD., CALDWELL, ID 83687DATE: JOB NUMBER:MKT19 AUG 2022 DRAWN BY: CHECKED BY:JLH NSW, ST, SKCOPYRIGHT 2023HATCH DESIGNARCHITECTUREDESCRIPTION- COMMENTSDATEDELTA