Loading...
HomeMy WebLinkAboutCFD Review Cleveland Flex 403 Blaine Street  Caldwell, ID 83605  Phone 208-649-1266  Fax 208-455-3014 Date 05/09/2023 Caldwell City – Planning and Zoning Re: Dear Alex Jones, CASE NO. ANN22-000016 and CPM23-000003: A request by ALC Architecture to annex parcel R3244000000, an 18.72 acre parcel of land at 5617 Cleveland Blvd, located south of Ustick Road and west of N. Midway on the north side of the Nampa-Caldwell Blvd. corridor, in Caldwell, Idaho, to include any adjacent rights-of-way, with a proposed split zoning of M-1 (Light Industrial) on the north half of the property and C-3 on the south half of the property closest to Cleveland Blvd, to include the approval of a Development Agreement associated with ANN22-000016. Concurrently, the applicant is requesting a comprehensive plan map amendment on the northern half of the property from a CS (Commercial & Service) to an MP (Manufacturing & Production) land use designation, to include approval of Resolution #84-23 Associated with CPM22- 23-000003. The subject parcel is contiguous to current City of Caldwell parcels to the west and east boundaries and is the last remaining infill parcel along this portion of the Nampa-Caldwell Blvd. The Caldwell City Fire Department has reviewed and can approve the application subject to compliance with all the following code requirements and conditions of approval. Any deviation from this plan is subject to Fire Department approval. Please note that unless stated otherwise, this memo represents the requirements of the 2018 International Fire Code (IFC) as adopted by the Idaho State Fire Marshal’s Office. Comments: 1. Fire hydrants, capable of producing the required fire flow, shall be located along approved fire lanes. Fire hydrant spacing shall meet the requirements of IFC table C105.1.1 (IFC 507.3, IFC B105.2, IFC C105). 2. Structures greater than 30-feet in height will require aerial fire access roadways. These roadways shall be a minimum of 26-feet in width and located at least 15-feet but no more than 30-feet from the building. (IFC D105) 3. Roadway serving a fire hydrant shall be a minimum of 26-feet in width. (IFC D103.1) 403 Blaine Street  Caldwell, ID 83605  Phone 208-649-1266  Fax 208-455-3014 4. Dead-end fire apparatus access roads exceeding 150 feet (45 720 mm) in length shall be provided with an approved area for turning around fire apparatus. (IFC 503.2.5) 5. Fire apparatus access roads shall extend to within 150 feet of all portions of the exterior walls of the first story of a building measured by an approved route around the exterior of the building or facility. (IFC 503.1.1) 6. Monument signage for addressing will be required at the entrance and at all intersections within the project. (IFC 505.1) 7. Fire apparatus access roads shall have an unobstructed width of not less than 20 feet and an unobstructed vertical clearance of not less than 13 feet 6 inches. (IFC 503.2.1) 8. The minimum outside turning radius of a fire apparatus access road shall be 48 feet. The minimum inside turning radius shall be 28 feet. (IFC 503.2.4) 9. Fire apparatus access roads shall have an approved driving surface of asphalt, concrete or other approved driving surface and can support the imposed load of fire apparatus weighing at least 80,000 pounds. Please provide documentation the road surface meets this standard. (IFC D102.1) 10. Fire apparatus access roads shall not exceed 10 percent in grade. (IFC D103.2) 11. For streets having a width less than 33 feet back of curb to back of curb parking shall be restricted on one side; for streets having a width less than 27 feet back of curb to back of curb parking shall be restricted on both sides. A note on the face of the final plat is required noting the parking restriction prior to signing of the final plat. In addition, No Parking signs shall be installed in accordance with the requirements of the IFC. (IFC 503.8) 12. Fire suppression system shall be required bases on construction type, size, function and committee. 13. Access gates shall comply with requirements of the IFC. If gates are electronically operated, they shall be equipped with an automatic opening mechanism activated by the Opticom system. Manual gates shall be secured with a Knox brand padlock (IFC 503.6, D103.5). 14. Approved secondary access roads shall be provided per section D106 of the 2018 IFC. 15. Secondary access from the site is required per section D104.2 due to the totality of the requested fire area. (318,200sqft) (IFC 503.6, D104.2). General Requirement: Fire Department required fire hydrants, access, and street identification shall be installed prior to construction or storage of combustible materials on site. Provisions may be made for temporary access and identification measures. 403 Blaine Street  Caldwell, ID 83605  Phone 208-649-1266  Fax 208-455-3014 Specific building construction requirements of the International Building Code, International Fire Code and City of Caldwell Code will apply. However, these provisions are best addressed by a licensed Architect at time of building permit application. Regards, Alan Perry Division Chief Fire Marshal Caldwell Rural Fire Protection District Aperry@cityofcaldwell.org