Loading...
HomeMy WebLinkAboutSUP22-000020 Mini Storage 403 Blaine Street  Caldwell, ID 83605  Phone 208-649-1266  Fax 208-455-3014 Date 9/29/2022 Caldwell City – Planning and Zoning Re: SUP22-000020 Dear Alex Jones, This is A request by Clint Walker to build a traditional mini storage facility. The facility will include approximately 419 units and the single family home will be used for onsite property management. The development site is located in a C-2 (COMMUNITY COMMERCIAL) zone. The proposed location is on S Indiana Ave on parcel R04041 at 2813 S INDIANA AVE in Caldwell, Idaho. The Caldwell City Fire Department has reviewed and can approve the application subject to compliance with all the following code requirements and conditions of approval. Any deviation from this plan is subject to Fire Department approval. Please note that unless stated otherwise, this memo represents the requirements of the 2018 International Fire Code (IFC) as adopted by the Idaho State Fire Marshal’s Office. Comments: 1. On site Fire hydrants, capable of producing the required fire flow, shall be located along approved fire lanes. Fire hydrant spacing shall meet the requirements of IFC table C105.1.1 (IFC 507.3, IFC B105.2, IFC C105). 2. Roadway serving a fire hydrant shall be a minimum of 26-feet in width. (IFC D103.1) 3. Dead-end fire apparatus access roads exceeding 150 feet (45 720 mm) in length shall be provided with an approved area for turning around fire apparatus. (IFC 503.2.5) 4. Fire apparatus access roads shall extend to within 150 feet of all portions of the exterior walls of the first story of a building measured by an approved route around the exterior of the building or facility. (IFC 503.1.1) 5. Fire apparatus access roads shall have an unobstructed width of not less than 20 feet and an unobstructed vertical clearance of not less than 13 feet 6 inches. (IFC 503.2.1) 6. The minimum outside turning radius of a fire apparatus access road shall be 48 feet. The minimum inside turning radius shall be 28 feet. (IFC 503.2.4) 7. Fire apparatus access roads shall have an approved driving surface of asphalt, concrete or other approved driving surface and can support the imposed load of fire apparatus weighing at least 75,000 pounds. Please 403 Blaine Street  Caldwell, ID 83605  Phone 208-649-1266  Fax 208-455-3014 provide documentation the road surface meets this standard. (IFC D102.1) 8. Fire apparatus access roads shall not exceed 10 percent in grade. (IFC D103.2) 9. A Knox Box / Key Box is required for this structure. Please contact the Fire Prevention Office at (208) 455-4703 for ordering information. Location shall be determined with the Fire Code Official at time of installation. (IFC 503.6, D103.5). General Requirement: Fire Department required fire hydrants, access, and street identification shall be installed prior to construction or storage of combustible materials on site. Provisions may be made for temporary access and identification measures. Specific building construction requirements of the International Building Code, International Fire Code and City of Caldwell Code will apply. However, these provisions are best addressed by a licensed Architect at time of building permit application. Regards, Alan Perry Division Chief Fire Marshal Caldwell Rural Fire Protection District Aperry@cityofcaldwell.org