I visited this address last week but was not able to talk to the owners regarding the reasons
for an appeal. After reviewing what I could I believe the combustible structure should not
only be moved to at least five feet from the property line but also that same distance away
from the residence. The increased separation between the existing fence, the neighbor's
shed, and the applicant's house would be a vital life -safety benefit Dennis.
I W,
Page 1 of 1
Anne Marie. Skinner
From:
Timothy J. Frans
Sent:
Thursday, March 12, 2009 1:11 PM
To:
Anne Marie. Skinner
Subject: RE: jerry galaway appeal
In that case the Engineering Dept. okay with the shed being placed anywhere on his property as long as
he understands that if ever needed for any reason the shed would have to be moved (when requested) at
his sole expense.
� J, Frans
Engineering Dept.
City of Caldwell
(208) 455-3006
From: Anne Marie. Skinner
Sent: Thursday, March 12, 2009 1:01 PM
To: Timothy J. Frans
Subject: jerry galaway appeal
TJ,
Jerry's shed is like a stor-mor shed in that it's not on a permanent foundation — rather it could be moved with the
appropriate equipment.
4wsn&lfa,,,,-4e,Ske;n
Senior Planner
City of Caldwell
Planning and Zoning
621 Cleveland Blvd.
Caldwell, ID 83605
208-455-4662
208-455-3050 fax
3/12/2009
1�i) -a
L
MEMO
Date: March 5, 2009
To: TJ Frans, Engineering Department
Dennis Wilson, Fire Department
Adele Adams, Building Department
From: Anne Marie Skinner, Senior Planner
Caldwell P & Z Department
RE: Case No. APP-01-09
Attached please find a land use application that you are invited to
review. This case is scheduled to be presented before the Caldwell City
Council on Monday, April 6, 2009 at 7:00 pm.
Case No. APP-01-09 a request by Jerry Galaway to appeal the accessory use
ordinance and allow an accessory building (a shed) to remain eighteen inches from
the property line rather than re -locating the shed to the required minimum five feet
from the property line. The shed is less than 120 square feet in area. The site is
located at 11440 Serenac Street.
Please review the attached application and information and provide me
with your written input. I request that you e-mail any comments to me
as soon as possible but no later than Monday, March 30, 2009.
E-mail: amskinner@ci.caldwell.id.us
I will assume that you have no objections, concerns or comments if you
do not reply to this request within the requested timeframe. If you
have any questions, you may contact me at 455-4662.
rBUILDING PLANNING
r
SECTION R302
EXTERIOR WALL LOCATION
R302.1 Exterior walls. Construction. projections, openings
and penetrations of exterior walls of dwellings and accessory
buildings shall comply with Table R302.1. These provisions
shall not apply to walls. projections. openings or penetrations
in walls that are perpendicular to the line used to determine the
fire separation distance. Projections beyond the exterior wall
shall not extend more than 12 inches (305 mm,, into the areas
where openings are prohibited.
Exceptions:
I. Detached tool sheds and storag.- sheds. playhouses
and similar structures exempted from permits are not
required to provide wall protection based on location
on the lot. Projections beyond the exterior wal; shall
not extend over the lot line.
2 Detached garages accessory to a dwelling located
within 2 feet (610 mm) of a lot line are permitted to
have roof eave projections not exceeding 4 inches
(102 mm).
3. Foundation vents installed in compliance with this
cods are permitted.
SECTION R303
LIGHT, VENTILATION AND HEATING
R303.1 Habitable rooms. All habitable rooms shall have an
aggregate glaring area of not less than 8 percent of the floor
area of such rooms. Natural %endlation Shall be through win-
dows, doors. louvers or other approved openings to the outdoor
air. Such openings shall be provided with ready access or shall
otherwise be readily controllable by the building occupants.
The minimum openable area to the outdoors shall be 4 percent
of the floor area being ventilated.
Exceptions:
1. The Blazed areas need not be openable where the
opening is not required by Section R310 and an
approved mechanical ventilation system capable of
producing 0.35 air change per hour in the room is
installed or a whole -house mechanical ventilation
system is installed capable of supplying outdoor ven-
tilation air of 15 cubic feet per minute (efm) (78 Us)
per occupant computed on the basis of two occupants
for the first bedroom and one occupant for each addi-
tional bedroom.
2. The glazed areas need not be installed in rooms where
Exception l above is satisfied and artificial light is pro-
vided capable of producing an average illumination of
6 footcandles (65 lux) over the area of the room at a
height of 30 inches (762 mm) above the floor level.
3. Use of sunmorn additions and patio covers. as defined in
Section R202, shall be permitted for natural ventilation
ifin excess of 40 percent of the exterior sunroom walls
are open. or are enclosed only by insect screening.
R303.2 Adjoining rooms. For the purpose of determining
light and ventilation requirements. any room shall be consid-
ered as a portion of an adjoining room when at least one-half of
the area of the common wall is open and unobstructed and pro-
vides an opening of not less than one -tenth of the floor area of
the interior room but not less than 25 square feet (2.3 m'-).
Exception: Openings required for light and/or ventilation
shall be permitted to open into a thermally isolated sunroom
addition or patio cover. provided that there is an openable
area between the adjoining room and the sunroorn addition
or patio cover of not less than one -tenth of the floor area of
the interior room but not less than 20 square feet (2 m'). The
minimum openable area to the outdoors shall be based upon
the total floor area being ventilated.
R303.3 Bathrooms. Bathrooms. water closet compartments
and other similar rooms shall be provided with aggregate glaz-
ing area in windows of not less than 3 square feet (0.3 m'-),
one-half of which must be openable.
Exception: The glazed areas shall not be required where arti-
ficial light and a mechanical ventilation system are provided.
The minimum ventilation rates shall be 50 cubic feet per min-
ute (24 Us) for intermittent ventilation or 20 cubic feet per
minute (10 Us) for continuous ventilation. Ventilation air
from the space shall be exhausted directly to the outside.
TABLE R302.1
EXTERIOR WALLS
MINIMUM
MINIMUM FIRE
EXTERIOR WALL ELEMENT
FIRE -RESISTANCE RATING
SEPARATION DISTANCE
I (Fire-resistancc rated)
1 hour with exposure from both sides
— 0 feet —
Walls
(Not tire -resistance rated)
€ 0 hours_
5 feet
A(Fire-resistance
rated)
1 hour on the underside
4 feet
PR3jectinns
(Not fire -resistance ratedi
-----
_
_ —_ 0 hours __- _
5 feet
Not ullowed
NIA
-- < 3 feet
01x rinfs 25% Maximuin of Wail Area
0 hours
3 feet
Unlimited
EE_
I 0 hours ;
5 feet
_
Complp with Section R317.3
< 5 feet —
Penetrations All
Nonc required
—5 feet
NIA = Nut Applicable.
2006 INTERNATIONAL RESIDENTIAL CODE