HomeMy WebLinkAboutPublic Agencyat PUBLIC AGENCY ITEM DATE,SUBMITTED BY Fi.o-h$\-\TfY A*/f c,$DWEgg O crru*"tt city and Rural O" Department "Saving Uyes, Prctecting @IU" Andrew Cater, Deputy Chief/Fire Marshal Fire Prevention Division 310 S 7h Ave, Caldwell lD 83605 Phone 208-455-3032 Fax208455-3014 TO: Jarom Wagoner, Senior Planner FROM: Andrew Cater DATE: 0111812014 RE: Whitney Springs subdivision #3 Final plat The following are the Caldwell Fire Department minimum requirements provided by the adopted international fire codes to provide fire protection for this development. 505.1 Address ldentification. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. Please submit address design to the Fire Marshal's office for review and approval prior to installation. Street naming shall be reviewed and approved by the fire Marshal's office prior to installation. Approved Street signs shall be installed prior to any building permits being issued. Fire Flow Requirements for Buildings, Section 8105.1 lntemational Fire Code One and two family dwellings. The minimum Fire Flow and flow duration for one and two family dwellings having a fire flow calculation area that does not exceed 3,600 square feet shall be 1,000 Gallons per minute for t hour. Fire flow and flow durations having a fire flow calculation area in excess of 3,600 square feet shall not be less than that specified in Table 8105.1 . Contact the fire Marshal's office for further clariftcation of table B105.1 of the lnternational fire code. EXCEPTION: A reduction in required fire flows of 50 percent as approved is allowed when the building is equipped with an automatic sprinkler system. All fire hydrant locations and required fire flows shall be witnessed and approved by the Caldwell Fire Marshal's office prior to any building permits being issued. Fire Hydrants shall be placed not more than 500 feet apart and at corners of roadways whenever practical. Operational fire Hydrants and street signage are required before the issue of any building permits. Fire department access roads shall be provided and maintained in accordance with section 503 and appendix D of the lntemational Fire Code. IFC D103.6 Signs. Fire apparatus roads shall be marked with permanent No Parking - Fire Lane signs complying with this section of the lFC. Signs shall have a minimum dimension of 12 inches wide by 18 inches high and have red letters on a white reflective background. Signs shall be posted on one or both sides of the fire apparatus roads as required by section D103.6.'1 Roads 20lo 26 feet in width shall be posted on both sides as a fire lane. Roads more than 26 feet in width to 32 feet shall be posted on one side as a fire lane. Sincerely, Andrew ,t Deputy Chief / Fire Marshal Po-\ J BE cUE I