Loading...
HomeMy WebLinkAboutLandscape Plan 2DWG INDEX: J1184-LAND-OYOO 31601-M-611100 VICINITY MAP r SITE CALDWELL, IDAHO QTY. SYMBOL COMMON NAME BOTANICAL NAME SIZE REMARKS MATURITY HxW TREES O ARMSTRONG MAPLE ACER RUBRUM 'ARMSTRONG' 2" CAL. B&B 30'x3O' O JAPANESE PAGODA TREE SOPHORA JAPONICA 2" CAL. B&B 40'x4O' OKATSURA TREE CERCIDIPHLLUUM JAPONIGUM 2" CAL. B&B 30'x30' O RIVER BIRCH BETULA NIGRA 2" CAL. B&B 30'x2O' Q PRAIRIFIRE FLOWERING CRABAPPLE MALUS X PRAIRIFIRE 2" CAL. B&B 15'xl5' O SPRINGSNOW FLOWERING CRABAPPLE MALUS X SPRINGSNOW 2" CAL. B&B 15'xl5' AUSTRIAN PINE PINUS NIGRA 6-7' HT. B&B 30'x2O' LAWN (SOD)- TALL TURF TYPE FESCUE LAWN (SEED)- TALL TURF TYPE FESCUE LANDSCAPE NOTES: 1. PLANT AS SHOWN IN ACCORDANCE WITH THE PLANT SCHEDULE BY HEIGHT, SPREAD AND CALIPER. DESCRIPTIONS SHOWN ARE MINIMUM 11. RE -SOD ALL AREAS DAMAGED DURING CONSTRUCTION, TRENCHING REQUIREMENTS. OPERATIONS ANC/OR PLANT BED CONSTRUCTION, 2. PLANT MATERIAL SHALL BE FURNISHED IN THE QUANTITIES/OR SPACING 12. CONTRACTOR SHALL INSTALL IRRIGATION SYSTEM PRIOR TO INSTALLING SHOWN OR NOTED. IN CASE OF DISCREPANCIES BETWEEN THE PLAN ANY PLANT MATERIAL. AND PLANT LIST, THE PLAN SHALL DICTATE, 13. IRRIGATION - 3. FINISH GRADES OF LAWN OR PLANT BED AREAS PRIOR TO PLANTING - ALL LANDSCAPED AREAS SHALL HAVE AN AUTOMATIC UNDERGROUND SHALL BE: IRRIGATION SYSTEM WHICH PROVIDES 10OX COVERAGE AND IS PROPERLY -SEEDED AREAS - j¢ INCH BELOW TOP OF ADJACENT PAVEMENT OF ZONED FOR REQUIRED WATER USES. EACH ZONE IS TO BE IRRIGATED ANY KIND. MTN SEPARATE INDIVIDUAL STATIONS. -SODDING AREAS -1 INCH BELOW TOP OF ADJACENT PAVEMENT OF -PLANTER BEDS AND LAWN AREAS SHALL HAVE SEPARATE ANY KIND. HYDRO -ZONES. -PLANTER BED AREAS - 3 INCHES BELOW TOP OF ADJACENT -POP-UP SPRINKLER HEAD SHALL HAVE A MINIMUM RISER HEIGHT OF 4 PAVEMENT OF ANY KIND. NCHES IN LAWN AREAS AND 12 INCHES AT PLANTER BEDS. -PLANTER BEDS SHALL HAVE DRIP IRRIGATION SYSTEMS OR POP-UP 4. ALL PLANTER BEDS AND TREE PITS SHALL HAVE A MINIMUM OF 3" DEEP SPRAY SYSTEMS AT OWNER'S DISCRETION. OF BARK MULCH OR EQUAL. -ELECTRONIC WATER DISTRIBUTION/TIMING CONTROLLERS SHALL BE PROVIDED. 5. CONTRACTOR TO VERIFY UTILITY LOCATIONS PRIOR TO START. -MINIMUM CONTROLLER REQUIREMENTS ARE AS FOLLOWS: CONTRACTOR TO REPAIR DAMAGES TO EXISTING UTILITIES, PAVEMENTS, -PRECISE INDIVIDUAL STATION TIMING ETC., WHICH OCCUR DURIN G CONSTRUCTION. -RUN TIME CAPABILITIES FOR EXTREMES IN PRECIPITATION RATES -MINIMUM OF ONE PROGRAM FOR EACH HYDROZONE 6. ALL PLANTS SHALL MEET OR EXCEED CURRENT AMERICAN ASSOCIATION -SUFFICIENT MULTIPLE CYCLES TO AVOID WATER RUN-OFF OF NURSERYMAN'S STANDARD SPECIFICATIONS. -POWER FAILURE BACKUP FOR ALL PROGRAMMED STATIONS -INDIVIDUAL VALVED WATERING STATIONS WILL BE DESIGNED AND 7. THE CONTRACTOR SHALL TEST THE SITE SOIL AFTER ROUGH GRADING IS INSTALLED TO PROVIDE WATER TO RESPECTIVE COMPLETE TO DETERMINE SOIL AMENDMENTS REQUIRED IN ORDER TO HYDRO -ZONES. PROVIDE AN ACCEPTABLE GROWING MEDIUM FOR THE PROPOSED -SPRINKLER HEADS SHALL BE ADJUSTED TO TO REDUCE PLANTING. SUBMIT COPY OF REPORT TO LANDSCAPE ARCHITECT FOR OVERSPRAY ON TO IMPERVIOUS SURFACES SUCH AS BUILDINGS, REVIEW. SIDEWALKS, DRIVEWAYS AND PARKING AREAS. 8. PERFORM CLEAN UP DURING INSTALLATION OF LANDSCAPING WORK AND UPON COMPLETION OF THE WORK. 9. ALL SUBS77TUT70NS AND PLAN CHANGES MUST BE APPROVED BY THE LANDSCAPE ARCHITECT/OWNER. 10. ALL TREES SHALL BE SUPPORTED IMMEDIATELY AFTER PLANTING BY STAKING IN ACCORDANCE WITH THE DETAIL PROVIDED. SI(YWAY DRIVE - PIRR v1 13 (i I -----_ ---- 1 -------------------- I r----------------� a z z 1 x CA I k •.1 I SCALE � -- 100 0 50 100 200 �I j ( FEET) 1 INCH = 100 FT LANDSCAPE PLAN PREVAILING WJD DIRECTION LANDSCAPE ARCHITECT/CONTACT: RODNEY EVANS, ASLA W&H PACIFIC 3130 S. OWYHEE ST. LIMB UP LOWER BRANCHES TO AN BOISE, ID 83705-4768 (208) 342-5400 (4) RUBBER CINCH TIES 8' HEIGHT ONO ALL A 11REE7 PLANTED BARK MULCH LAYER - 3" DEPTH. DEVELOPER INFORMATION: TREE WRAP FROM GROUND TO FIRST SET ROOT BALL 1" ABOVE FREEHOLD DEVELOPMENT, LLC BRANCH = ADJACENT FINISH GRACE P.O. BOX 190087 WATER RETENTION BASIN- 2" HIGH BOISE, IDAHO 83719 REMOVE BURLAP & TWINE °0 (208) 841-9106 FROM TOP OF BALL a AFTER STAKING ^ If� Iy�FINISH GRADE ENGINEER INFORMATION: X. COMMERCIAL FERTILIZER TABLETS BACKFILL WITH SOIL PLANTING MI SEE SPECIFICATIONS FOR AD0177ONAL W&H PACIFIC q INFORMATION. 3130 S. OWYHEE ST. io f 4r 7L 1 - BOISE, ID 83705-4768 TREE ROOT BARRIER- 1�2' ABOVE F UNDISTURBED SUBSOIL (208) 342-5400 111111111 GRADE - WHERE TREES 2"x 2"x 8'-O" CEDAR STAKES. (2 ARE PLANTED IN THE MEDIAN PER TREE) DO NOT PENETRATE 2x ROOTBALL DIAMETER ROOT BALL. NOTES: 1. THE STAKING OF TREES IS TO BE THE CONTRACTOR'S OPTION: HOWEVER, THE CONTRACTOR IS RESPONSIBLE TO INSURE THAT ALL TREES ARE PLANTED STRAIGHT AND THAT THEY REMAIN STRAIGHT FOR A MINIMUM OF 1 YEAR. 2. IN THE EVENT OF A QUESTION OR LACK OF CLARITY ON THE DRAWINGS, THE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCH17ECT BEFORE PROCEEDING. 3. LANDSCAPE CONTRACTOR IS TO N077FY THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION OF PLANT MATERIAL. 4. WRAP AROUND THE TREE TRUNKS AND STAKES USING EITHER THE STANDARD OR FIGURE EIGHT TYING METHOD. SECURE THE 71ES TO THE STAKES WITH GALVANIZED NAILS TO PREVENT SLIPPAGE. DECIDUOUS TREE PLANTING SME N.T.S. h v � U d' ti I cuco o �o � o oT N ti Gi 11 N N 6 6 l7 U O ul co ^ W v a a W r r U — m ED ~ p W > ¢o U 1r z CL U Q _O W a Q a a � m a m w m o w O p Q, o o -.J Q Qu Lu O J UO sN J C) Q zZ W 0 U I1, O � z °\j Q (Q� Q W O F Lu Lu Z vJ � Q O U \ J (n 3 v� Q p J R U T O LJ J p U V) SHEET L1