HomeMy WebLinkAboutLandscape Plan 2DWG INDEX:
J1184-LAND-OYOO
31601-M-611100
VICINITY MAP
r SITE
CALDWELL, IDAHO
QTY.
SYMBOL
COMMON NAME
BOTANICAL NAME
SIZE
REMARKS
MATURITY HxW
TREES
O
ARMSTRONG MAPLE
ACER RUBRUM 'ARMSTRONG'
2" CAL.
B&B
30'x3O'
O
JAPANESE PAGODA TREE
SOPHORA JAPONICA
2" CAL.
B&B
40'x4O'
OKATSURA
TREE
CERCIDIPHLLUUM JAPONIGUM
2" CAL.
B&B
30'x30'
O
RIVER BIRCH
BETULA NIGRA
2" CAL.
B&B
30'x2O'
Q
PRAIRIFIRE FLOWERING CRABAPPLE
MALUS X PRAIRIFIRE
2" CAL.
B&B
15'xl5'
O
SPRINGSNOW FLOWERING
CRABAPPLE
MALUS X SPRINGSNOW
2" CAL.
B&B
15'xl5'
AUSTRIAN PINE
PINUS NIGRA
6-7' HT.
B&B
30'x2O'
LAWN (SOD)- TALL TURF TYPE FESCUE
LAWN (SEED)- TALL TURF TYPE FESCUE
LANDSCAPE NOTES:
1.
PLANT AS SHOWN IN ACCORDANCE WITH THE PLANT SCHEDULE BY
HEIGHT, SPREAD AND CALIPER. DESCRIPTIONS SHOWN ARE MINIMUM
11. RE -SOD ALL AREAS DAMAGED DURING CONSTRUCTION, TRENCHING
REQUIREMENTS.
OPERATIONS ANC/OR PLANT BED CONSTRUCTION,
2.
PLANT MATERIAL SHALL BE FURNISHED IN THE QUANTITIES/OR SPACING
12. CONTRACTOR SHALL INSTALL IRRIGATION SYSTEM PRIOR TO INSTALLING
SHOWN OR NOTED. IN CASE OF DISCREPANCIES BETWEEN THE PLAN
ANY PLANT MATERIAL.
AND PLANT LIST, THE PLAN SHALL DICTATE,
13. IRRIGATION -
3.
FINISH GRADES OF LAWN OR PLANT BED AREAS PRIOR TO PLANTING
- ALL LANDSCAPED AREAS SHALL HAVE AN AUTOMATIC UNDERGROUND
SHALL BE:
IRRIGATION SYSTEM WHICH PROVIDES 10OX COVERAGE AND IS PROPERLY
-SEEDED AREAS - j¢ INCH BELOW TOP OF ADJACENT PAVEMENT OF
ZONED FOR REQUIRED WATER USES. EACH ZONE IS TO BE IRRIGATED
ANY KIND.
MTN SEPARATE INDIVIDUAL STATIONS.
-SODDING AREAS -1 INCH BELOW TOP OF ADJACENT PAVEMENT OF
-PLANTER BEDS AND LAWN AREAS SHALL HAVE SEPARATE
ANY KIND.
HYDRO -ZONES.
-PLANTER BED AREAS - 3 INCHES BELOW TOP OF ADJACENT
-POP-UP SPRINKLER HEAD SHALL HAVE A MINIMUM RISER HEIGHT OF 4
PAVEMENT OF ANY KIND.
NCHES IN LAWN AREAS AND 12 INCHES AT PLANTER BEDS.
-PLANTER BEDS SHALL HAVE DRIP IRRIGATION SYSTEMS OR POP-UP
4.
ALL PLANTER BEDS AND TREE PITS SHALL HAVE A MINIMUM OF 3" DEEP
SPRAY SYSTEMS AT OWNER'S DISCRETION.
OF BARK MULCH OR EQUAL.
-ELECTRONIC WATER DISTRIBUTION/TIMING CONTROLLERS SHALL BE
PROVIDED.
5.
CONTRACTOR TO VERIFY UTILITY LOCATIONS PRIOR TO START.
-MINIMUM CONTROLLER REQUIREMENTS ARE AS FOLLOWS:
CONTRACTOR TO REPAIR DAMAGES TO EXISTING UTILITIES, PAVEMENTS,
-PRECISE INDIVIDUAL STATION TIMING
ETC., WHICH OCCUR DURIN G CONSTRUCTION.
-RUN TIME CAPABILITIES FOR EXTREMES IN PRECIPITATION RATES
-MINIMUM OF ONE PROGRAM FOR EACH HYDROZONE
6.
ALL PLANTS SHALL MEET OR EXCEED CURRENT AMERICAN ASSOCIATION
-SUFFICIENT MULTIPLE CYCLES TO AVOID WATER RUN-OFF
OF NURSERYMAN'S STANDARD SPECIFICATIONS.
-POWER FAILURE BACKUP FOR ALL PROGRAMMED STATIONS
-INDIVIDUAL VALVED WATERING STATIONS WILL BE DESIGNED AND
7.
THE CONTRACTOR SHALL TEST THE SITE SOIL AFTER ROUGH GRADING IS
INSTALLED TO PROVIDE WATER TO RESPECTIVE
COMPLETE TO DETERMINE SOIL AMENDMENTS REQUIRED IN ORDER TO
HYDRO -ZONES.
PROVIDE AN ACCEPTABLE GROWING MEDIUM FOR THE PROPOSED
-SPRINKLER HEADS SHALL BE ADJUSTED TO TO REDUCE
PLANTING. SUBMIT COPY OF REPORT TO LANDSCAPE ARCHITECT FOR
OVERSPRAY ON TO IMPERVIOUS SURFACES SUCH AS BUILDINGS,
REVIEW.
SIDEWALKS, DRIVEWAYS AND PARKING AREAS.
8.
PERFORM CLEAN UP DURING INSTALLATION OF LANDSCAPING WORK AND
UPON COMPLETION OF THE WORK.
9.
ALL SUBS77TUT70NS AND PLAN CHANGES MUST BE APPROVED BY THE
LANDSCAPE ARCHITECT/OWNER.
10.
ALL TREES SHALL BE SUPPORTED IMMEDIATELY AFTER PLANTING BY
STAKING IN ACCORDANCE WITH THE DETAIL PROVIDED.
SI(YWAY DRIVE
- PIRR
v1
13 (i
I
-----_ ---- 1
--------------------
I
r----------------�
a
z
z
1
x
CA
I
k
•.1
I
SCALE � --
100 0 50 100 200 �I
j
( FEET)
1 INCH = 100 FT
LANDSCAPE PLAN
PREVAILING WJD DIRECTION LANDSCAPE ARCHITECT/CONTACT:
RODNEY EVANS, ASLA
W&H PACIFIC
3130 S. OWYHEE ST.
LIMB UP LOWER BRANCHES TO AN BOISE, ID 83705-4768
(208) 342-5400
(4) RUBBER CINCH TIES 8' HEIGHT ONO ALL
A 11REE7 PLANTED
BARK MULCH LAYER - 3" DEPTH. DEVELOPER INFORMATION:
TREE WRAP FROM GROUND TO FIRST SET ROOT BALL 1" ABOVE FREEHOLD DEVELOPMENT, LLC
BRANCH = ADJACENT FINISH GRACE P.O. BOX 190087
WATER RETENTION BASIN- 2" HIGH BOISE, IDAHO 83719
REMOVE BURLAP & TWINE °0 (208) 841-9106
FROM TOP OF BALL a
AFTER STAKING ^ If� Iy�FINISH GRADE
ENGINEER INFORMATION:
X.
COMMERCIAL FERTILIZER TABLETS BACKFILL WITH SOIL PLANTING MI
SEE SPECIFICATIONS FOR AD0177ONAL W&H PACIFIC
q INFORMATION. 3130 S. OWYHEE ST.
io f 4r 7L 1 - BOISE, ID 83705-4768
TREE ROOT BARRIER- 1�2' ABOVE F UNDISTURBED SUBSOIL (208) 342-5400
111111111
GRADE - WHERE TREES 2"x 2"x 8'-O" CEDAR STAKES. (2
ARE PLANTED IN THE MEDIAN PER TREE) DO NOT PENETRATE
2x ROOTBALL DIAMETER ROOT BALL.
NOTES:
1. THE STAKING OF TREES IS TO BE THE CONTRACTOR'S OPTION: HOWEVER, THE CONTRACTOR IS RESPONSIBLE TO
INSURE THAT ALL TREES ARE PLANTED STRAIGHT AND THAT THEY REMAIN STRAIGHT FOR A MINIMUM OF 1 YEAR.
2. IN THE EVENT OF A QUESTION OR LACK OF CLARITY ON THE DRAWINGS, THE CONTRACTOR IS TO NOTIFY THE
LANDSCAPE ARCH17ECT BEFORE PROCEEDING.
3. LANDSCAPE CONTRACTOR IS TO N077FY THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION OF PLANT MATERIAL.
4. WRAP AROUND THE TREE TRUNKS AND STAKES USING EITHER THE STANDARD OR FIGURE EIGHT TYING METHOD.
SECURE THE 71ES TO THE STAKES WITH GALVANIZED NAILS TO PREVENT SLIPPAGE.
DECIDUOUS TREE PLANTING
SME N.T.S.
h
v
�
U
d'
ti
I
cuco
o
�o
�
o
oT
N
ti
Gi
11
N N
6
6
l7
U
O ul
co
^
W
v
a
a
W
r r
U
—
m
ED
~
p W
> ¢o
U 1r
z CL
U Q
_O
W
a
Q a
a �
m
a
m
w m o
w
O p
Q,
o
o
-.J
Q
Qu
Lu O
J
UO
sN
J
C)
Q
zZ
W
0
U
I1,
O
�
z
°\j
Q
(Q�
Q
W
O
F
Lu
Lu
Z
vJ
�
Q
O
U
\
J
(n
3
v�
Q
p
J
R
U
T
O
LJ
J
p
U
V)
SHEET
L1