Loading...
HomeMy WebLinkAboutPublic Agency SUB14P-97 Ross Acrese) PUBLIC AGENCY SUBMITTED BYDATEITEM Io^ L{,^-^,l&o.Oc]-l".r 30, \q f\a\-LrV\O \'A e'l..}64 .J,tUa-Oa}:\xr 3D, \??1Ll--\*r r€ ? LiJn'- -\ L^-A*- a CALDWELL a FIRE DEPARTMENT TO DATE : FBOM: SUBJECT : october 3a, ).997 T,inda Jarnes, Director, Development Services Joseph S i.Iva, Fire Marshal Ross ComnerciaL Acres ctTY oF cALDwELL 310 South 7lh Avenue CAIDWELL, IDAHO 83605 (208) 4sS3032 AS to Protecting Your ProtrErU So,ulng Liues the following minimum fireIf the above referenced project reguj-rements will need to be metprotection: approvedprovide 2 Premises rdentification. Al-I numbers or addresses shall be 6" and clearly visible from the street. The numbers shall- contrast h/ith their background. They sha1l be displayed at onthe center portion of the buildj.ng. UEC 901.4.4 A11 processes taking pl-ace in any of the commercial buildingswill comply with the 1994 Uniform Eire Code. 3 ire l,Iar i.Iva shaf fl IJJ/0cT 30 IE e I V tr oa ?r>a 1. The project wil-l- have to comply with the 1994 Uniform Fire Code for water supply and access. a Sewer Service - The notes on the plat indicate that sewage disposal is to be provided by municipal sewage facilities. There is not a City sewer iine available to this property. Sewage might be handled with site disposal systems, which would be under the purview of Southwest District Health DePartment. The location of any drain fields, also, must be cleared with the City Engineering Department' A water line is scheduled for construction this coming summer, within the bounds of the section line road and a 25 foot separation is required between water lines and any drain field. \Vater Service - Notes on the preliminary plat indicate that domestic water is to be provided by the municipal water system. There is not a water line to this site, although one is scheduled for construction in late 1998. Any development prior to that time would require the potable water supply be provided by wells on site. O 4 5 6. Curb. Gutter and Sidewalk -The preliminary plat does not indicate the developer's 7 intent with regard to curb, gutter and sidewalk. The normal requirement is that curb and gutter be provided on al1 street frontages. The Engineering Depaftment recommends that curb and gutter be provided on all street frontages excePt the unopened right-of-way on the north boundary of this proposed subdivision. It is also the normal requirement that sidewalk be provided on all street frontages. The Engineering Department would recommend that no sidewalk be required on the unopened righrof-way or on Andy Lane with its sub-standard right-of-way width. 5 foot sidewalk should be provided on the section line road frontage. Paving - There is no indication on the preliminary plat of the developer's intent with regard to sheet paving. The normal requirement is that paving be required on all opened road frontages. This would include half the street section width plus 7 1,/2 feet on the section line road, and the gap between the existing paving and the lip of gutter on Aldy Lane. 8 Storm Drainage - There is no indication on the preliminary plat of the developer's intent with regard to storm drainage. That storm drainage system must be designed in compliance with the Engineering Department's Stormwater Policy. A copy is available from the Engineering Depatment. Irrigation - There is no indication on the plat of the developer's intent with regard to existing irrigation facilities on the site or with the provision of irrigation water to the site. It is normal requirement that an irrigation plan be proposed and that the proposed plan receive the approval of the goveming irrigation district, if any and the City. The proposed preliminary plat indicates some bordering ProPerty is unplatted, when in fait, it is a portion of Parks Orchard Tracts Subdivision. The Department would ask that the preliminary plat be revised to reflect this additional ilformation. 9 10. ?a't